Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CFD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Design of high deflection foils for MHK applications - CFD files

The Ocean Renewable Power Company's (ORPC's) goal is to design, develop, and test hydrofoils with large deflections. The effects of the deflections on cross-flow turbine performance would be evaluated in order to inform design considerations for full-scale water turbines and other marine hydrokinetic devices. OpenFOAM V1912 files for straight foil model scale turbines in the University of New Hampshire tow tank. Strut Locations = (0.13, 0.225, 0.450, 0.675, 0.900) [m] Tip speed ratio = 2.40

16 TIDAL AND WAVE POWER↗

Comparative Analysis via CFD Simulation on the Impact of Graphite Anode Morphologies on the Discharge of a Lithium-Ion Battery

The morphology of electrode materials plays a crucial role in determining the performance of lithium-ion batteries. Traditional computational models often simplify graphite flakes as uniformly sized spheres, which limits their predictive accuracy. In this study, we present a computational workflow that overcomes these limitations by incorporating a more realistic representation of graphite morphologies. This workflow is designed to be flexible and reproducible, enabling efficient evaluation of electrochemical performance across diverse material structures. By exploring different graphite morphologies, our approach accelerates the optimization of material preparation techniques and processing conditions. Our findings reveal that incorporating greater morphological complexity leads to significant deviations from classical model predictions. Instead, our refined model offers a more accurate representation of battery discharge behavior, closely aligning with experimental data. This improvement underscores the importance of detailed morphological descriptions in advancing battery design and performance assessments. To promote accessibility and reproducibility, we provide the developed code for seamless integration with the COMSOL API, allowing researchers to implement and adapt it easily. This computational framework serves as a valuable tool for investigating the impact of graphite morphology on battery performance, bridging the gap between theoretical modeling and experimental validation to enhance lithium-ion battery technology.

25 ENERGY STORAGE↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CFD Simulations of Lower Plenum Mixing

Review of model development and validation performed in the Advanced Reactor Technologies (ART) program for thermal mixing at the outlet of High Temperature Gas Reactors (HTGRs). Understanding the mixing that occurs in the lower plenum in an HTGR is necessary to facilitate design improvements and to perform reactor safety analysis. Numerical models are one possible approach to gain a better understanding of mixing in the lower plenum. Given the complexity of the geometry and the intense mixing present, it is important to perform validation of numerical models. Three models have been developed during FY2025: a porous media with Pronghorn, a Reynolds Averaged Navier Stokes (RANS) with STAR-CCM+, and a Large Eddy Simulation (LES) with NekRS. The reference facility is a scaled-down version of the lower plenum of the High Temperature Gas-Cooled Reactor - Pebble-bed Module (HTR-PM) demonstration reactor. Preliminary results of the porous media and the RANS shows general good agreement against experimental benchmark data. Future work will leverage high-fidelity results obtained through LES to guide model selection and improvements to the lower-fidelity models, with particular attention to the Pronghorn porous media.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

ECAR-6415 Rev 0 CFD Analysis of the Primary Coolant Apparatus Test Core with Wire Spacers for Heterogeneous Power Distributions

Primary Coolant Apparatus Test (PCAT) is a thermal-hydraulic test loop for Microreactor Applications Research Validation and Evaluation (MARVEL) reactor. The heater elements were manufactured within a straightness tolerance for the designated gap thickness of 1.0 mm, but several elements have been distorted out of tolerance during the welding process. The distortion of heater rods can lead to flow maldistribution and excessive hotspot where the gap between two heater rods is too tight. In order to secure the heater-to-heater gap in an acceptable range, wire spacers are adopted for the PCAT. The wire spacers affect the thermal-hydraulic performance of the PCAT because they enhance the flow mixing among the flow subchannels in the core region. The objectives of this ECAR is to evaluate the effects of the wire spacers on the thermal-hydraulic performance of the PCAT core region by assuming several heterogeneous power distributions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Revisiting the empirical particle-fluid coupling model used in DEM-CFD by high-resolution DEM-LBM-IMB simulations: A 2D perspective

The work investigates the applicability of the unresolved Computational Fluid Dynamics and Discrete Element Method (CFDDEM) technique based on empirical equations for fluid-particle coupling. We first carry out a series of representative volume element simulations using the high-resolution particle-resolved Lattice Boltzmann method and Discrete Element Method (LBMDEM) coupled by an Immersed Moving Boundary (IMB) scheme. Then, we compare the results obtained by both LBMDEM and empirical equations used in unresolved CFDDEM with analytical solutions. It is found that the existing empirical equations used in solving fluid-particle interactions in 2D CFDDEM fail to accurately calculate the hydrodynamic force applied to solid particles. The underlying reason is that the existing empirical models are obtained based on 3D experimental results and thus are not applicable to 2D problems. Based on the simulation results, a new drag coefficient model is then proposed. The estimated drag forces using the new model are compared favourably with the simulated ones, indicating the good performance of the proposed model.

42 ENGINEERING↗

Pore-scale CFD simulations of clay mobilization in natural porous media due to fresh water injection

The present work investigates mechanisms of permeability impairment as a result of low-salinity fluid injection into brine-saturated porous media containing dispersible clays. Here, we present a computational fluid dynamics model at the pore-scale to simulate detachment, migration and straining of fine particles in porous media. The model uses an immersed boundary method to simulate the motion of clay fines in a fluid. In addition to the hydrodynamic forces, we model the Derjaguin-Landau-Verwey-Overbeek forces (DLVO) between clay fines and grains. Our simulations show the impact of the injected fluid's salinity and velocity on the concentration of clay fines retained on the grain surface. We see clay particles dislodging from the grain surface in clusters of up to 12 particles. Our simulation results also demonstrate clogging of narrow pore spaces by the detached particles from the grain surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuum Correlations from CFD-DEM Modeling of Conduction Heat Transfer in Granular Flows

Heat transfer between a surface and flowing particles is analyzed to improve the accuracy of continuum models for wall-to-bed heat transfer in a fluidized bed. Discrete element modeling (DEM) is used to model a fluidized bed heat exchanger where heat enters the system through a heated wall. The DEM heat transfer predictions are validated against published experimental work (Brewster et al., 2024) with less than 15% error. In previous work by Morris et al. (2015), a continuum model was developed using data from high-fidelity DEM simulations of chute flows. In the current study, the continuum model is extended and validated for fluidized beds. The sensitivity of the continuum heat transfer model parameters, which was not quantified in previous studies, is also investigated. It is observed that for a given particle with specific properties, e.g. the particle size, roughness, and conduction lens radius, the continuum correlation developed for heat transfer from a heated boundary to the particle bed depends mainly on the solid fraction or porosity of the particle bed for a given fluid. The new continuum heat transfer model is then validated over a wide range of superficial velocities via comparisons to both discrete element and experimental data. It is shown that this correlation is valid for a large range of particle flow conditions from chute flows to fluidized beds with less than 10% error as compared to DEM predictions.

14 SOLAR ENERGY↗