Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CEA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Risk Assessment of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

As part of the BNL-JLab-CEA Electron Ion Collider (EIC) collaboration, the design of a 2 T, 2.8 m bore diameter, 3.8 m long conduction cooled superconducting detector magnet design is completed. Such magnet will be employed at the interaction region of ePIC for physics experiment. The magnet is a passive shielded solenoidal magnet system consisting of 3 coils wound with specially designed conductor using NbTi Rutherford type cable in copper stabilized channel. This paper describes the risk analysis as the part of Failure Modes and Effects Analysis (FMEA) that was carried out as a team to identify their various failure modes and risks associated with the magnets system. In conclusion, this FMEA is intended to become the content of the designed document as an integral part of the engineering assessment and the statement of work for the potential vendors towards design and built.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Techno-economic comparison of three scenarios for upgrading a hemicellulose-rich pre-pulping extract to mixed-alcohols: Techno-Economic Comparison of Three Scenarios for Upgrading a Hemicellulose-rich Pre-pulping Extract to Mixed-Alcohols

Conversion of a hemicellulose-rich pre-pulping extract into long-chain alcohols could alleviate problems facing the liquid fuel supply and could boost the revenues of pulp mills. Kraft pulping requires only the cellulose fraction of wood, leaving much of the hemicellulose available for extraction and subsequent conversion into gasoline-blendable alcohols. Additionally, three possible pathways for upgrading the hemicelluloses are: CKA: carboxylates → ketones → alcohols; CEA: carboxylates → esters → alcohols, and CHEA: carboxylates → acids → esters → alcohols. The scenarios were modeled using AspenPlus® to determine material and energy balances. Economic parameters were determined using the Aspen Process Economic Analyzer. The minimum ethanol selling price (MESP) for a 1000 tpd facility, which takes into account the operating and capital costs, was found to be: 3.31 dollars for CKA, 4.56 dollars for CEA, and 4.26 dollars for the CHEA. The cost of hydrogen necessary for hydrogenolysis proved to be a notable expense

09 BIOMASS FUELS↗

A Surgeon's View on Endarterectomy and Stenting in 2011: Lest We Forget, It's All About Preventing Stroke

It has been nearly 60 years since Felix Eastcott published his seminal paper on carotid reconstruction, which paved the way for carotid endarterectomy (CEA) and then carotid artery stenting (CAS) to assume prominent roles in the prevention of stroke. Yet the ensuing 60 years has witnessed repeated cycles of challenges to practice, professional mistrust, conflicts of interest, dogmatic retention of traditional management strategies, inappropriate corporate interventions, and a general failure to adapt to new evidence. Even the performance of large-scale randomised trials has been associated with rancour and a lack of consensus. This article reviews the history of invasive interventions in the treatment of carotid disease and makes a plea to both the surgical and interventional communities that the fundamental priority must always be the prevention of stroke. It concludes with an appeal for colleagues to collaborate to determine how best to treat patients during the hyperacute period after the onset of symptoms and to identify a smaller cohort of asymptomatic patients who are truly at high risk for stroke in whom to target CAS or CEA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Constant Momentum Acceleration Decouples Energy and Space Focusing in Distance-of-Flight and Time-of-Flight Mass Spectrometries

Time-of-flight (TOF) and distance-of-flight (DOF) mass spectrometers require means for focusing ions at the detector(s) because of initial dispersions of position and energy at the time of their acceleration. Time-of-flight mass spectrometers ordinarily employ constant energy acceleration (CEA), which creates a space-focus plane at which the initial spatial dispersion is corrected. In contrast, constant-momentum acceleration (CMA), in conjunction with an ion mirror, provides focus of the initial energy dispersion at the energy focus time for ions of all m/z at their respective positions along the flight path. With CEA, the initial energy dispersion is not simultaneously correctable as its effect on ion velocity is convoluted with that of the spatial dispersion. The initial spatial dispersion with CMA remains unchanged throughout the field-free region of the flight path, so spatial dispersion can be reduced before acceleration. Improved focus is possible when each dispersion can be addressed independently. With minor modification, a TOF mass spectrometer can be operated in CMA mode by treating the TOF detector as though it were a single element in the array of detectors that would be used in a DOF mass spectrometer. Significant improvement in mass resolution is thereby achieved, albeit over a narrow range of m/z values. In this paper, experimental and theoretical results are presented that illustrate the energy-focusing capabilities of both DOF and TOF mass spectrometry.

Dennis, Elise↗

The challenges and opportunities in cumulative effects assessment

The cumulative effects of increasing human use of the ocean and coastal zone have contributed to a rapid decline in ocean and coastal resources. As a result, scientists are investigating how multiple, overlapping stressors accumulate in the environment and impact ecosystems. These investigations are the foundation for the development of new tools that account for and predict cumulative effects in order to more adequately prevent or mitigate negative effects. Despite scientific advances, legal requirements, and management guidance, those who conduct assessments—including resource managers, agency staff, and consultants—continue to struggle to thoroughly evaluate cumulative effects, particularly as part of the environmental assessment process. Even though 45 years have passed since the United States National Environmental Policy Act was enacted, which set a precedent for environmental assessment around the world, defining impacts, baseline, scale, and significance are still major challenges associated with assessing cumulative effects. In addition, we know little about how practitioners tackle these challenges or how assessment aligns with current scientific recommendations. To shed more light on these challenges and gaps, we undertook a comparative study on how cumulative effects assessment (CEA) is conducted by practitioners operating under some of the most well-developed environmental laws around the globe: California, USA; British Columbia, Canada; Queensland, Australia; and New Zealand. We found that practitioners used a broad and varied definition of impact for CEA, which led to differences in how baseline, scale, and significance were determined. We also found that practice and science are not closely aligned and, as such, we highlight opportunities for managers, policy makers, practitioners, and scientists to improve environmental assessment.

54 ENVIRONMENTAL SCIENCES↗

A Phase 1/2 and Biomarker Study of Preoperative Short Course Chemoradiation With Proton Beam Therapy and Capecitabine Followed By Early Surgery for Resectable Pancreatic Ductal Adenocarcinoma

Purpose: To evaluate the safety, efficacy and biomarkers of short-course proton beam radiation and capecitabine, followed by pancreaticoduodenectomy in a phase 1/2 study in pancreatic ductal adenocarcinoma (PDAC) patients. Methods and Materials: Patients with radiographically resectable, biopsy-proven PDAC were treated with neoadjuvant short-course (2-week) proton-based radiation with capecitabine, followed by surgery and adjuvant gemcitabine. The primary objective was to demonstrate a rate of toxicity grade ≥3 of <20%. Exploratory biomarker studies were performed using surgical specimen tissues and peripheral blood. Results: The phase 2 dose was established at 5 daily doses of 5 GyE. Fifty patients were enrolled, of whom 35 patients were treated in the phase 2 portion. There were no grade 4 or 5 toxicities, and only 2 of 35 patients (4.1%) experienced a grade 3 toxicity event (chest wall pain grade 1, colitis grade 1). Of 48 patients eligible for analysis, 37 underwent pancreaticoduodenectomy. Thirty of 37 (81%) had positive nodes. Locoregional failure occurred in 6 of 37 resected patients (16.2%), and distant recurrence occurred in 35 of 48 patients (72.9%). With median follow-up of 38 months, the median progression-free survival for the entire group was 10 months, and overall survival was 17 months. Biomarker studies showed significant associations between worse survival outcomes and the KRAS point mutation change from glycine to aspartic acid at position 12, stromal CXCR7 expression, and circulating biomarkers CEA, CA19-9, and HGF (all, P<.05). Conclusions: This study met the primary endpoint by showing a rate of 4.1% grade 3 toxicity for neoadjuvant short-course proton-based chemoradiation. Treatment was associated with favorable local control. In exploratory analyses, KRAS{sup G12D} status and high CXCR7 expression and circulating CEA, CA19-9, and HGF levels were associated with poor survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Health Economics in Radiation Oncology: A Systematic Review

Purpose: Despite the rising costs in radiation oncology, the impact of health economics research on radiation therapy practice analysis patterns is unclear. We performed a systematic review of cost-effectiveness analyses (CEAs) and cost-utility analyses (CUAs) to identify trends in reporting quality in the radiation oncology literature over time. Methods and Materials: A systematic review of radiation oncology economic evaluations up to 2014 was performed, using MEDLINE and EMBASE databases. The Consolidated Health Economic Evaluation Reporting Standards guideline informed data abstraction variables including study demographics, economic parameters, and methodological details. Tufts Medical Center CEA registry quality scores provided a basis for qualitative assessment of included studies. Studies were stratified by 3 time periods (1995-2004, 2005-2009, and 2010-2014). The Cochran-Armitage trend test and linear trend test were used to identify trends over time. Results: In total, 102 articles were selected for final review. Most studies were in the context of a model (61%) or clinical trial (28%). Many studies lacked a conflict of interest (COI) statement (67%), a sponsorship statement (48%), a reported study time horizon (35%), and the use of discounting (29%). There was a significant increase over time in the reporting of a COI statement (P<.001), health care payer perspective (P=.019), sensitivity analyses using multivariate (P=.043) or probabilistic methods (P=.011), incremental cost-effectiveness threshold (P<.001), secondary source utility weights (P=.010), and cost effectiveness acceptability curves (P=.049). There was a trend toward improvement in Tuft scores over time (P=.065). Conclusions: Recent reports demonstrate improved reporting rates in economic evaluations; however, there remains significant room for improvement as reporting rates are still suboptimal. As fiscal pressures rise, we will rely on economic assessments to guide our practice decisions and policies. We recommend improved adherence to published guidelines and further research to determine the clinical implications of our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uniformity measurements and new positioning algorithms for wavelength-shifting fiber neutron detectors

Wavelength-shifting (WLS) fiber scintillator detectors were successfully installed at two neutron powder diffractometers at the Spallation Neutron Source (SNS). But, they have the following second-order disadvantages: (i). they cannot have both high efficiency and images free of ghosting (position misassignment) concomitantly; (ii). the apparent detection efficiency and spatial resolution are not uniform. These issues are related to the diffusion of scintillation photons and the fluctuation in the number of photons (quantum noise) collected by photo-multiplier tubes (PMTs). Therefore, to mitigate these two issues, we developed two statistics-based positioning algorithms, i.e., a centroid algorithm (CEA) and a correlation algorithm (CA). Compared with the generally used maximum-photon algorithm (MPA), CEA eliminates the ghosting with only about a 10% loss in detection efficiency, and provides better uniformity in detection efficiency and intrinsic background. CA can effectively eliminate ghosting too, but the loss of efficiency at the group boundaries of PMTs is large. Our results indicate that both algorithms can reduce the influence of quantum noise on the neutron positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AGR-2: The first irradiation of French HTR fuel in Advanced Test Reactor

AGR-2, the second irradiation of the US program for qualification of the NGNP fuel, is open to international participation within the scope of the Generation IV International Forum. In this frame, it includes in its multi-capsule irradiation rig an irradiation of French HTR fuel manufactured in the CAPRI line (GAIA facility at CEA/Cadarache and AREVA/CERCA compacting line at Romans). The AGR-2 irradiation is designed to place our first fabrications of HTR particles under operating conditions that are representative of ANTARES project while keeping close to the test range of the German fuel as much as possible, which is the reference in terms of irradiation behavior. A few batches of particles and 12 fuel compacts were produced and characterized in 2009 by CEA and CERCA. The fuel main characteristics are in conformity with our specifications and in compliance with INL requirements. The AGR-2 experiment is based on the design and devices used in the first experiment of the AGR program. The design makes it possible to monitor the irradiation conditions and in particular, the temperature, the power and the fission products released from fuel particles. The in pile equipment consists of a multi-capsule device designed to simultaneously irradiate six independent capsules with temperature control. The out-of-core part consists of the equipment for actively controlling temperature and measuring the fission products release on-line. The target conditions for the irradiation experiment were defined with the aim of comparing the results obtained under irradiation with German particles along with the objectives of reaching burn-up and fluence targets to validate the behavior of our fuel in a significant range (15% FIMA – 5 × 1025 n/m2 at 600 EFPD with centerline fuel temperature about 1100 degrees C). These conditions have to be representative of ANTARES project characteristics. These target conditions were compared with final results from neutron and thermal design studies performed by INL team, and preliminary thermal mechanical ATLAS calculations were carried out by CEA from this pre-design. Despite the mean burn-up achieved in approximately 600 EFPD being a little high (16.3% FIMA max. associated with a low fluence up to 2.85 × 1025 n/m2), this irradiation will nevertheless encompass the range of irradiation effects covered in our experimental objectives (maximum stress peak at start of irradiation then sign inversion of the stress in the SiC layer). In addition, the fluence and burn-up acceleration factors are very similar to those of the German reference experiments. This experimental irradiation began in July 2010 in the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) and first results have been acquired.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technology pathways for energy- and water-efficient controlled environment agriculture: A review of technologies, implementation pathways, and regional use cases

Controlled Environment Agriculture (CEA) offers high-yield, climate-resilient food production, but high energy and resource demands challenge its sustainability. This paper synthesizes technologies that can improve outcomes across six categories—energy, CO 2 utilization, building envelope, hardware, water, and process—plus colocation strategies. We evaluate 80 technologies and define ten implementation pathways bundling complementary technologies to reduce energy use, optimize water consumption, and minimize emissions. Regional application is demonstrated through five U.S. case studies spanning different climates. A logic framework guides pathway selection for case studies based on climate, infrastructure, and regulatory context, informing context-sensitive technology deployment. Results show energy intensity reductions of 3–55 %, ranging from energy management programs to comprehensive lighting retrofits; water savings of 20–40 % through closed-loop recirculation; and emissions reductions of 3–100 %, with strategic energy management achieving 3–5 % and renewable electricity paired with electrified heating achieving up to 100 %. Text mining revealed that energy, hardware, and process technologies account for 91 % of literature coverage. Water, building envelope, and CO 2 utilization remain underexplored, indicating priorities for future research. This integrative approach to technology assessment supports growers, developers, and policymakers in aligning CEA system design with local conditions, improving resource efficiency and addressing gaps in cross-domain technology coverage.

Controlled environment agriculture↗

Interinstitutional Study of the New EURO-GANEX Process Resistance by Gamma Irradiation Test Loops

As part of the homogeneous actinides recycling strategy, the EURO-GANEX process is one of the most promising options to achieve the goal of minor actinides recovery. However, EURO-GANEX also has various drawbacks that are being addressed. Improvements made to EURO-GANEX system have resulted in the emergence of the so-called New EURO-GANEX process, where the composition of the solvent has been modified by replacing TODGA and DMDOHEMA with cis-mTDDGA in the organic phase and SO3-Ph-BTP with PyTri-Diol in the aqueous phase in order to resolve important issues. The objective of this work is twofold: evaluate the gamma radiolysis resistance of the new EURO-GANEX process by dynamic irradiation conditions simulating the three main steps of the process and validate the design of CIEMAT Náyade, CEA Marcel and INL irradiation loop devices since each of them mimics different aspects of the real process. Náyade and the INL loops could irradiate together the organic and aqueous phases, whereas in the CEA loop, the irradiated solvent is recycled continuously inside a platform with several stages of mixer-settlers containing aqueous flows simulating the three main steps of the process. The extraction performances and changes in the composition of the solvent have been analysed during the irradiation experiment by different techniques: gamma spectrometry and ICP-MS/OES for cations or tracers extraction, and HPLC-MS to quantify the degradation and evaluate the degradation compounds. Additionally, in spite of some differences between the three-irradiation facilities, this inter-institutional study shows that they are three comparative tools, which provide results on the stability towards radiolysis of a liquid-liquid extraction system. Favourable extraction results for the different steps are obtained according to the static irradiation studies found in literature. However, the degradation of cis-mTDDGA is appreciable leading to degradation compounds, some of which form precipitates and produce important changes in viscosity, important aspects that must be addressed prior to the successful industrial application of the new EURO-GANEX process.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pressure-induced magnetovolume effect in CoCrFeAl high-entropy alloy

High-entropy alloys (HEAs) composed of multiple-principal elements with (nearly) equimolar ratio establish a new conceptual framework for alloy design and hold a promise for extensive applications in industry, akin to the controlled expansion alloys (CEAs), such as Invar alloys. Spontaneously, one question emerges - would it be possible to synthesize a novel class of alloys combining the virtues of both CEAs and HEAs? Here, we report the pressure-induced magnetovolume effect in the body-centered-cubic CoCrFeAl HEA coupled with magnetic phase transitions from ferromagnetic to paramagnetic, and to non-magnetic states, originating from the successive collapses of local magnetic moments of Co and Fe. The observed magnetovolume anomalies, occurring in a progressive way, tailor appreciably the coefficient of thermal expansion of CoCrFeAl. These results further strengthen HEAs’ anticipated potential for designing multifunctional materials in virtue of their multiple outstanding properties, and reveal possible routes for their future synthesis.

36 MATERIALS SCIENCE↗

New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 x 10{sup 20} n/cm{sup 2}. A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detection of special nuclear materials with the associate particle technique

In the frame of the French trans-governmental R and D program against chemical, biological, radiological, nuclear and explosives (CBRN-E) threats, CEA is studying the detection of Special Nuclear Materials (SNM) by neutron interrogation with fast neutrons produced by an associated particle sealed tube neutron generator. The deuterium-tritium fusion reaction produces an alpha particle and a 14 MeV neutron almost back to back, allowing tagging neutron emission both in time and direction with an alpha particle position-sensitive sensor embedded in the generator. Fission prompt neutrons and gamma rays induced by tagged neutrons which are tagged by an alpha particle are detected in coincidence with plastic scintillators. This paper presents numerical simulations performed with the MCNP-PoliMi Monte Carlo computer code and with post processing software developed with the ROOT data analysis package. False coincidences due to neutron and photon scattering between adjacent detectors (cross talk) are filtered out to increase the selectivity between nuclear and benign materials. Accidental coincidences, which are not correlated to an alpha particle, are also taken into account in the numerical model, as well as counting statistics, and the time-energy resolution of the data acquisition system. Such realistic calculations show that relevant quantities of SNM (few kg) can be distinguished from cargo and shielding materials in 10 min acquisitions. First laboratory tests of the system under development in CEA laboratories are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical feedback cavity-enhanced absorption spectroscopy with a 3.24 μm interband cascade laser

The development of interband cascade lasers (ICLs) has made the strong C-H transitions in the 3 μm spectral region increasingly accessible. We present the demonstration of a single mode distributed feedback ICL coupled to a V-shaped optical cavity in an optical feedback cavity-enhanced absorption spectroscopy (OF-CEAS) experiment. We achieved a minimum detectable absorption coefficient, α{sub min}, of (7.1±0.2)×10{sup −8} cm{sup −1} for a spectrum of CH{sub 4} at 3.24 μm with a two second acquisition time (100 scans averaged). This corresponds to a detection limit of 3 ppb CH{sub 4} at atmospheric pressure, which is comparable to previously reported OF-CEAS instruments with diode lasers or quantum cascade lasers. The ability to frequency lock an ICL source in the important 3 μm region to an optical cavity holds great promise for future spectroscopic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate measurements and temperature dependence of the water vapor self-continuum absorption in the 2.1 μm atmospheric window

In spite of its importance for the evaluation of the Earth radiative budget, thus for climate change, very few measurements of the water vapor continuum are available in the near infrared atmospheric windows especially at temperature conditions relevant for our atmosphere. In addition, as a result of the difficulty to measure weak broadband absorption signals, the few available measurements show large disagreements. We report here accurate measurements of the water vapor self-continuum absorption in the 2.1 μm window by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) for two spectral points located at the low energy edge and at the center of the 2.1 μm transparency window, at 4302 and 4723 cm{sup −1}, respectively. Self-continuum cross sections, C{sub S}, were retrieved with a few % relative uncertainty, from the quadratic dependence of the spectrum base line level measured as a function of water vapor pressure, between 0 and 16 Torr. At 296 K, the C{sub S} value at 4302 cm{sup −1} is found 40% higher than predicted by the MT-CKD V2.5 model, while at 4723 cm{sup −1}, our value is 5 times larger than the MT-CKD value. On the other hand, these OF-CEAS C{sub S} values are significantly smaller than recent measurements by Fourier transform spectroscopy at room temperature. The temperature dependence of the self-continuum cross sections was also investigated for temperatures between 296 K and 323 K (23-50 °C). The derived temperature variation is found to be similar to that derived from previous Fourier transform spectrometer (FTS) measurements performed at higher temperatures, between 350 K and 472 K. The whole set of measurements spanning the 296-472 K temperature range follows a simple exponential law in 1/T with a slope close to the dissociation energy of the water dimer, D{sub 0} ≈ 1100 cm{sup −1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review of laser produced multi-keV X-ray sources from metallic foils, cylinders with liner, and low density aerogels

Experimental results obtained within the last fifteen years on multi-keV X-ray sources irradiated with nanosecond scale pulse duration 3ω laser light at TW power levels by CEA and collaborators are discussed in this review paper. Experiments were carried out on OMEGA and GEKKO XII laser facilities where emitting materials in the 5–10 keV multi-keV energy range are intermediate Z value metals from titanium to germanium. Results focused on conversion efficiency improvement by a factor of 2 when an underdense plasma is created using a laser pre-pulse on a metallic foil, which is then heated by a second laser pulse delayed in time. Metal coated inner surface walls of plastic cylindrical tube ablated by laser beam impacts showed that plasma confinement doubles X-ray emission duration as it gives adequate plasma conditions (electron temperature and density) over a long period of time. Low-density aerogels (doped with metal atoms uniformly distributed throughout their volume or metal oxides) contained in a plastic cylinder have been developed and their results are comparable to gas targets. A hybrid target concept consisting of a thin metal foil placed at the end of a cylinder filled with low density aerogel has emerged as it could collect benefits from pre-exploded thin foils, efficient laser absorption in aerogel, and confinement by cylinder walls. All target geometry performances are relatively close together at a given photon energy and mainly depend on laser irradiation condition optimizations. Results are compared with gas target performances from recent NIF experiments allowing high electron temperatures over large dimension low density plasmas, which are the principal parameters for efficient multi-keV X-ray production.

Girard, Frédéric↗

Neutronics qualification of the Jules Horowitz reactor fuel by interpretation of the VALMONT experimental program - Transposition of the uncertainties on the reactivity of JHR with JEF2.2 and JEFF3.1.1

The new European material testing Jules Horowitz Reactor (JHR), currently under construction in Cadarache center (CEA France), will use LEU (20% enrichment in {sup 235}U) fuels (U{sub 3}Si{sub 2} for the start up and UMoAl in the future) which are quite different from the industrial oxide fuel, for which an extensive neutronics qualification database has been established. The HORUS3D/N neutronics calculation scheme, used for the design and safety studies of the JHR, is being developed within the framework of a rigorous verification-validation-qualification methodology. In this framework, the experimental VALMONT (Validation of Aluminium Molybdenum uranium fuel for Neutronics) program has been performed in the MINERVE facility of CEA Cadarache (France), in order to qualify the capability of HORUS3D/N to accurately calculate the reactivity of the JHR reactor. The MINERVE facility using the oscillation technique provides accurate measurements of reactivity effect of samples. The VALMONT program includes oscillations of samples of UAl{sub x}/Al and UMo/Al with enrichments ranging from 0.2% to 20% and Uranium densities from 2.2 to 8 g/cm{sup 3}. The geometry of the samples and the pitch of the experimental lattice ensure maximum representativeness with the neutron spectrum expected for JHR. By comparing the effect of the sample with the one of a known fuel specimen, the reactivity effect can be measured in absolute terms and be compared to computational results. Special attention was paid to the rigorous determination and reduction of the experimental uncertainties. The calculational analysis of the VALMONT results was performed with the French deterministic code APOLLO2. A comparison of the impact of the different calculation methods, data libraries and energy meshes that were tested is presented. The interpretation of the VALMONT experimental program allowed the qualification of JHR fuel UMoAl8 (with an enrichment of 19.75% {sup 235}U) by the Minerve-dedicated interpretation tool: PIMS. The effect of energy meshes and evaluations put forward the JEFF3.1.1/SHEM scheme that leads to a better calculation of the reactivity effect of VALMONT samples. Then, in order to quantify the impact of the uncertainties linked to the basic nuclear data, their propagation from the cross section measurement to the final computational result was analysed in a rigorous way by using a nuclear data re-estimation method based on Gauss-Newton iterations. This study concludes that the prior uncertainties due to nuclear data (uranium, aluminium, beryllium and water) on the reactivity of the Begin Of Cycle (BOC) for the JHR core reach 1217 pcm at 2{sigma}. Now, the uppermost uncertainty on the JHR reactivity is due to aluminium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗