Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗

Continuous-wave planar laser induced fluorescence with a fast camera

We present planar, laser induced fluorescence (PLIF) measurements of the velocity-resolved distribution function of ions in a plasma using a modulated, narrow linewidth, continuous-wave laser. Plasma emission is acquired with a high frame rate camera, and the laser light is spread into a thin sheet so that an entire plane of the plasma is imaged at each interrogation wavelength. Fourier analysis is conducted on each pixel of the images to separate the modulated fluorescent emission from the background light. Argon ion temperatures and bulk flow maps are reported in a helicon plasma source, and standard single-point LIF measurements provide validation of the PLIF measurement.

47 OTHER INSTRUMENTATION↗

Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST

A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.

Delgado-Aparicio, L. F. (ORCID:0000000167394380)↗

Beam-pointing verification using x-ray pinhole cameras on the 60-beam OMEGA laser

On the OMEGA laser system, the beam-pointing accuracy is verified by irradiating a 4 mm diameter Au-coated spherical target with ~23 kJ of laser energy. Up to ten x-ray pinhole cameras record the x-ray emission from all 60-beam spots. A new set of algorithms has been developed to improve the accuracy of the pointing evaluation. An updated edge-finding procedure allows one to infer the center of the sphere with subpixel accuracy. A new approach was introduced to back-propagate the pixel locations on the 2D image to the 3D surface of the sphere. Furthermore, a fast Fourier transform-based de-noising method significantly improves the signal-to-noise of the data. Based on the beam-pointing analysis, hard-sphere calculations of the laser-drive illumination uniformity on the target surface and the decomposition of the illumination distribution into lower order modes (1–10) are evaluated.

47 OTHER INSTRUMENTATION↗

Coherent mode and turbulence measurements with a fast camera

This study employs a fast camera with frame rates up to 900,000 fps to measure the transfer of energy across spatial scales in helicon source plasmas and during flux rope mergers and the measurement of azimuthal mode structures in helicon plasmas. By extracting pixel-scale dispersion relations and power spectral density (PSD) measurements, we measure the details of turbulent wave modes and energy distribution across a broad range of spatial scales within the plasma. We confirm the presence of drift waves in helicon plasmas, as well as the existence of strong dissipation regions in the PSD at electron skin depth scales for both helicon and flux rope merger experiments. This approach overcomes many limitations of conventional probes, providing high spatial and temporal resolution, without perturbing the plasma.

Instruments & Instrumentation↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗

Novel soft x-ray multi-energy camera to study thermal plasmas on WEST

A multi-energy soft x-ray (SXR) pinhole camera has been built, calibrated and deployed on the WEST tokamak to aid the study of thermal plasmas. This novel imaging diagnostic technique employs a 2D pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. This innovation allows the simultaneous measurement of x-rays with space, time and energy resolution. Measurements at lower energy (2–6 keV) dominated by tungsten line emission are used to estimate the tungsten concentration and the plasma ΔZ eff . Measurements at higher energy (11–18 keV), where only continuum emission is present, are employed to infer the plasma electron temperature. Other applications of this powerful diagnostic include the determination of the plasma SXR centroid vertical position, characterization of tungsten UFOs and various real-time measurements.

electron temperature↗

Mitigation of the Brighter-fatter Effect in the LSST Camera

Abstract Thick, fully depleted charge-coupled devices are known to exhibit nonlinear behavior at high signal levels due to the dynamic behavior of charges collecting in the potential wells of pixels, called the brighter-fatter effect (BFE). The effect results in distorted images of bright calibration stars, creating a flux-dependent point-spread function that if left unmitigated, could make up a large fraction of the error budget in Stage IV weak-lensing (WL) surveys such as the Legacy Survey of Space and Time (LSST). In this paper, we analyze image measurements of flat fields and artificial stars taken at different illumination levels with the LSST Camera (LSSTCam) at SLAC National Accelerator Laboratory in order to quantify this effect in the LSSTCam before and after a previously introduced correction technique. We observe that the BFE evolves anisotropically as a function of flux due to higher-order BFEs, which violates the fundamental assumption of this correction method. We then introduce a new method based on a physically motivated model to account for these higher-order terms in the correction, and then we test the modified correction on both data sets. We find that the new method corrects the effect in flat fields better than it corrects the effect in artificial stars, which we suggest is the result of sub-pixel physics not included in this correction model. We use these results to define a new metric for the full-well capacity of our sensors and advise image processing strategies to further limit the impact of the effect on LSST WL science pathways.

47 OTHER INSTRUMENTATION↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm &#x00d7; 5mm &#x00d7; 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 &#x00d7; 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

NEXT-CRAB-0: a high pressure gaseous xenon time projection chamber with a direct VUV camera based readout

The search for neutrinoless double beta decay(0νββ) remains one of the most compelling experimentalavenues for the discovery in the neutrino sector.Electroluminescent gas-phase time projection chambers are wellsuited to 0νββ searches due to their intrinsicallyprecise energy resolution and topological event identificationcapabilities. Scalability to ton- and multi-ton masses requiresreadout of large-area electroluminescent regions with fine spatialresolution, low radiogenic backgrounds, and a scalable dataacquisition system. This paper presents a detector prototype thatrecords event topology in an electroluminescent xenon gas TPC viaVUV image-intensified cameras. This enables an extendable readoutof large tracking planes with commercial devices that reside almostentirely outside of the active medium. Following furtherdevelopment in intermediate scale demonstrators, this technique mayrepresent a novel and enlargeable method for topological eventimaging in 0νββ.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The 4D Camera: An 87 kHz Direct Electron Detector for Scanning/Transmission Electron Microscopy

We describe the development, operation, and application of the 4D Camera—a 576 by 576 pixel active pixel sensor for scanning/transmission electron microscopy which operates at 87,000 Hz. The detector generates data at ~480 Gbit/s which is captured by dedicated receiver computers with a parallelized software infrastructure that has been implemented to process the resulting 10–700 Gigabyte-sized raw datasets. The back illuminated detector provides the ability to detect single electron events at accelerating voltages from 30 to 300 kV. Through electron counting, the resulting sparse data sets are reduced in size by 10--300× compared to the raw data, and open-source sparsity-based processing algorithms offer rapid data analysis. The high frame rate allows for large and complex scanning diffraction experiments to be accomplished with typical scanning transmission electron microscopy scanning parameters.

47 OTHER INSTRUMENTATION↗

Dark Energy Camera photometry reveals extra-tidal stars around the Milky Way globular cluster NGC 6864 (M75)

ABSTRACT Globular clusters are prone to lose stars while moving around the Milky Way. These stars escape the clusters and are distributed throughout extended envelopes or tidal tails. However, such extra-tidal structures are not observed in all globular clusters, and yet there are no structural or dynamical parameters that can predict their presence or absence. NGC 6864 is an outer halo globular cluster with reported no observed tidal tails. We used Dark Energy Camera photometry reaching ∼4 mag underneath its main-sequence turnoff to confidently detect an extra-tidal envelope, and stellar debris spread across the cluster outskirts. These features emerged once robust field star filtering techniques were applied to the fainter end of the observed cluster main sequence. NGC 6864 is associated to the Gaia-Enceladus dwarf galaxy, among others 28 globular clusters. Up-to-date, nearly 64${{\ \rm per\,cent}}$ of them have been targeted looking for tidal tails and most of them have been confirmed to exhibit tidal tails. Thus, the present outcomes allow us to speculate on the possibility that Gaia-Enceladus globular clusters share a common pattern of mass loss by tidal disruption.

Piatti, Andrés E. (ORCID:0000000286790589)↗

The Dark Energy Camera All Data Everywhere cosmic shear project V: Constraints on cosmology and astrophysics from 270 million galaxies across 13,000 deg$^2$ of the sky

We present constraints on models of cosmology and astrophysics using cosmic shear data vectors from three datasets: the northern and southern Galactic cap of the Dark Energy Camera All Data Everywhere (DECADE) project, and the Dark Energy Survey (DES) Year 3. These data vectors combined consist of 270 million galaxies spread across 13,000 ${\rm deg}^2$ of the sky. We first extract constraints for $Λ$CDM cosmology and find $S_8= 0.805^{+0.019}_{-0.019}$ and $Ω_{\rm m} = 0.262^{+0.023}_{-0.036}$, which is consistent within $1.9 σ$ of constraints from the Planck satellite. Extending our analysis to dynamical dark energy models shows that lensing provides some (but still minor) improvements to existing constraints from supernovae and baryon acoustic oscillations. Finally, we study six different models for the impact of baryons on the matter power spectrum. We show the different models provide consistent constraints on baryon suppression, and associated cosmology, once the astrophysical priors are sufficiently wide. Current scale-cut approaches for mitigating baryon contamination result in a residual bias of $\approx 0.3σ$ in the $S_8, Ω_{\rm m}$ posterior. Using all scales with dedicated baryon modeling leads to negligible improvement as the new information is used solely to self-calibrate the baryon model on small scales. Additional non-lensing datasets, and/or calibrations of the baryon model, will be required to access the full statistical power of the lensing measurements. The combined dataset in this work represents the largest lensing dataset to date (most galaxies, largest area) and provides an apt testing ground for analyses of upcoming datasets from Stage IV surveys. The DECADE shear catalogs, data vectors, and likelihoods are made publicly available.

Anbajagane, D. [Chicago U., Astron. Astrophys. Ctr↗

Design and Characterization of an Optically Segmented Single Volume Scatter Camera Module

Here, the optically segmented single volume scatter camera (OS-SVSC) aims to image neutron sources for nuclear nonproliferation applications using the kinematic reconstruction of elastic double-scatter events. We report on the design, construction, and calibration of one module of a new prototype. The module includes 16 EJ-204 organic plastic scintillating bars individually wrapped in Teflon tape, each measuring 0.5cx0.5cmx20cm . The scintillator array is coupled to two custom silicon photomultiplier (SiPM) boards consisting of a 2x8 array of SensL J-Series-60035 SiPMs, which are read out by a custom 16 channel DRS4 based digitizer board. The electrical crosstalk between SiPMs within the electronics chain is measured as 0.76%±0.11% among all 16 channels. We report the detector response of one module including interaction position, time, and energy, using two different optical coupling materials: EJ-560 silicone rubber optical coupling pads and EJ-550 optical coupling grease. We present results in terms of the overall mean and standard deviation of the z -position reconstruction and interaction time resolutions for all 16 bars in the module. We observed the 1σz -position resolution for gamma interactions in the 0.3–0.4 MeVee range to be 2.24 cm ± 1.10 cm and 1.45 cm ± 0.19 cm for silicone optical coupling pad and optical grease, respectively. The observed 1σ interaction time resolution is 265 ps ± 29 ps and 235 ps ± 10 ps for silicone optical coupling pad and optical grease, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

Content-aware foveated camera for multi-target tracking

Modern image sensors deliver substantial space-time bandwidth, yet indiscriminate acquisition often overwhelms memory, computation, and downstream perception. We present a content-aware, multi-foveated camera that dynamically reallocates sensing and magnification to multiple regions of interest (ROIs). A phase-only spatial light modulator (SLM) serves as a solid-state, inertia-free beam-steering and lens element, enabling per-frame field-of-view (FOV) reconfiguration and content-aware target tracking. By interleaving frames across foveae, our system preserves a wide-FOV situational context while refreshing each ROI at high rates, thereby reducing data volume without degrading task performance. We constructed a prototype employing a single-SLM, single-sensor architecture and demonstrated its application in real-time multi-object tracking with dynamic ROI maintenance across multiple viewpoints. The approach offers a general pathway to integrate detection, tracking, and segmentation algorithms in the acquisition loop, shifting workload from post hoc processing to intelligent capture.

Zang, Zihan [Univ. of California, Los Angeles, CA ↗

Quantifying high-dimensional spatial entanglement with a single-photon-sensitive time-stamping camera

High-dimensional entanglement is a promising resource for quantum technologies. Being able to certify it for any quantum state is essential. However, to date, experimental entanglement certification methods are imperfect and leave some loopholes open. Using a single-photon-sensitive time-stamping camera, we quantify high-dimensional spatial entanglement by collecting all output modes and without background subtraction, two critical steps on the route toward assumptions-free entanglement certification. We show position-momentum Einstein–Podolsky–Rosen (EPR) correlations and quantify the entanglement of formation of our source to be larger than 2.8 along both transverse spatial axes, indicating a dimension higher than 14. Our work overcomes important challenges in photonic entanglement quantification and paves the way toward the development of practical quantum information processing protocols based on high-dimensional entanglement.

79 ASTRONOMY AND ASTROPHYSICS↗