A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intensified Tpx3Cam, a fast data-driven optical camera with nanosecond timing resolution for single photon detection in quantum applications

Here we describe a fast data-driven optical camera, Tpx3Cam, with nanosecond scale timing resolution and 80 Mpixel/sec throughput. After the addition of intensifier, the camera is single photon sensitive with quantum efficiency determined primarily by the intensifier photocathode. The single photon performance of the camera was characterized with results on the gain, timing resolution and afterpulsing reported here. The intensified camera was successfully used for measurements in a variety of applications including quantum applications. As an example of such application, which requires simultaneous detection of multiple photons, we describe registration of photon pairs from the spontaneous parametric down-conversion source in a spectrometer. We measured the photon wavelength and timing with respective precisions of 0.15 nm and 3 ns, and also demonstrated that the two photons are anti-correlated in energy.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Real-Time Multi-Vehicle Multi-Camera Tracking with Graph-Based Tracklet Features

An essential application in intelligent transportation systems is multi-target multi-camera tracking (MTMCT), where the target’s activity is tracked from different cameras. Although the tracking-by-detection scheme is the primary paradigm in MTMCT, the object association information from the video frames is lost. This is mainly because the multi-camera multi-object matching uses the information from the video frames separately. To solve this problem and leverage this association information, we propose an MTMCT framework, where features are built in the form of a graph and a graph similarity algorithm is used to match multi-camera objects. In this paper, we focus on the real-time scenario, where only the past images are used to match an object. Our method achieves an IDF1 score (the ratio of the number of correctly identified objects to the number of ground truth and average objects) of 0.75 with a rate of 14 frames per second (fps).

Engineering↗

Advancing 3D surface imaging: single-axis structured light illumination plenoptic camera with machine learning integration

Structured light illumination (SLI) is a configurable 3D surface imaging modality that can function largely independently of surface texture. At the same time, machine learning (ML) approaches are providing new ways to capture relevant information from SLI patterns, avoiding the need to develop advanced computer vision algorithms. By projecting an optical pattern onto a surface and measuring the apparent distortion of that pattern, one can determine surface topography from a single image. Common realizations of SLI 3D imaging use off-axis SLI to allow for parallax-based determination of depth; however, in constrained geometries, the ability to make single-axis measurements can be of major benefit. While plenoptic imaging (PI) cameras have long been developed for the purpose of single-axis 3D imaging, they are generally reliant on the surface texture of the measured object, thus making them unreliable in certain experimental conditions. Therefore, we present a single-axis 3D SLI plenoptic camera, which combines the single-axis benefits of PI technology while using coaxial SLI to maintain indifference to surface conditions. We also present a study of the camera capabilities paired with the development of several algorithms, including traditional feature tracking methods as well as ML methods, which are found to enhance resolution and range. We report depth sensitivity down to 0.2% $\frac{dz}{z_0}$. The single-axis SLI 3D plenoptic camera demonstrates potential applicability for in-situ topographical measurements under a wide range of conditions including, but not limited to, objects without trackable surface texture, high temperatures, and constrained geometry environments.

Imaging systems↗

In vitro and in vivo NIR fluorescence lifetime imaging with a time-gated SPAD camera

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo . Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

47 OTHER INSTRUMENTATION↗

Retrieving Point Cloud of Cloud Points (PCCP) Value-Added Product from Stereo Cameras

In this report, we refer to a pair of cameras that capture synchronized pictures with overlapping fields of view (FOV) as a stereo pair. Each stereo pair independently performs a stereo reconstruction of cloud points. Currently, there are three U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility stereo pairs (six cameras in total) positioned around the Southern Great Plains (SGP) observatory’s Central Facility (CF; Romps and Oktem 2017). Time-synchronized pictures from the two cameras in a stereo pair can be paired together to obtain a three-dimensional (3D) reconstruction of feature points by triangulation. This document explains how we use ARM stereo cameras and stereophotogrammetric principles to generate the Point Cloud of Cloud Points (PCCP) Value-Added Product (VAP). The PCCP VAP is essentially a set of 3D positions representing the locations of cloud features in the sky. Thousands of cloud features can be reconstructed instantly in each stereo pair's FOV, which covers an area of tens of square kilometers. Cloud base and cloud top heights can be extracted from the PCCP product.

42 ENGINEERING↗

Processing and Archiving Camera Data Effectively for Operando Neutron Measurement of Metal Additive Manufacturing

As the name suggests, The Operando Neutron Measurement of Metal Additive Manufacturing project conducted by ORNL’s Manufacturing Demonstration Facility (MDF) is experimenting with advanced additive metal manufacturing techniques while analyzing the process using the Spallation Neutron Source’s (SNS) beamline. As part of this experiment, the MDF is seeking to employ 2 XIMEA visible light cameras and a single infrared camera to analyze and correct manufacturing in real-time. The MDF requires a solution for capturing the high-resolution data feed from the cameras with compression while preserving enough detail for their software to detect and correct errors in real time. Our solution was to develop a Robot Operating System (ROS) driver to feed the camera data into ROS. From ROS, the feed is compressed and temporarily stored locally to a stripped 4 NVMe SSD RAID array. Post-experiment, the data is transitioned to long-term storage for archival purposes.

36 MATERIALS SCIENCE↗

Vegetation Warming Experiment: Landscape-scale digital camera imagery for vegetation phenology, Utqiagvik (Barrow), Alaska, 2019

Images captured using a StarDot NetCam SC phenocamera looking east from the top of the Barrow Environmental Observatory (BEO) Sled Shed, Utqiagvik, Alaska. The camera was installed to remotely monitor plant phenology and operation of the Brookhaven National Laboratory (BNL) TEST group's ZPW (Zero Power Warming) chambers during the growing season of 2019. Images were captured from early spring (4 April) through to mid fall (30 October). Snowmelt, vegetation growth and senescence, and snow accumulation were captured. Images were uploaded to the BNL FTP server every hour, then from 2019-06-27 to 2019-10-02 images were recorded every 10 minutes, then at hourly intervals until the end of data collection on 2019-10-30. Files were renamed with the date and time of the image. jpg images have been compressed in *.tar.gz format (5.6 GB). Closer fields of view (northeasterly) were also captured using 4 Wingscapes TimelapseCam cameras mounted on a mast on the sled shed. These cameras were operated from 2019-06-23 to 2019-09-25, with images recorded every 30 minutes from 9:00 to 16:30 Alaska daylight time (AKDT, UTC-8). Individual jpg images have been compressed in zip format for each camera and also presented as mp4 timelapse movies.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Digital camera imagery for vegetation phenology, Seward Peninsula, Alaska, 2019-2021

Time lapse camera images from Kougarok mile marker (MM) 64 and Teller MM 27 NGEE-Arctic field sites on the Seward Peninsula, Alaska, captured from July 2019 to August 2021. Thirty three Wingscape Timelapse Pro cameras were deployed targeting patches of low and tall shrubs (including Alnus sp. and Salix sp.) and general vegetation and landscape views. Images from were recorded at hourly intervals from 11 AM to 2 PM, continuously for 25 months and capture vegetation phenology, snow accumulation and snow melt events. This data package includes images (*.jpg), organized by site and camera ID, and metadata with details of the cameras used, number of images recorded, start and end dates, GPS locations and example fields of view. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Convective heating measurement by means of an infrared camera

The development of rapid and accurate wind tunnel techniques to measure convective heating distributions in complex reentry configurations is discussed. Major emphasis was put on the infrared camera technique. Its essence is the measurement of infrared emission from the surface of a wind tunnel model as a function of time. Prior calibration of the infrared camera relates the emission to the surface temperature of the model. The time history of the surface temperature can then be related to the heating rate by standard techniques. The output of the camera is an electrical signal that is tape-recorded in analog form, then digitized and processed by computer, so that automated and relatively rapid data reduction can be accomplished. In addition, the camera produces real-time visual displays of the infrared emission as pictures on an oscilloscope screen. These pictures give immediate indications of hot and cool spots on the model.

Compton, D. L.↗

Surveyor 3: Bacterium isolated from lunar retrieved television camera

Microbial analysis was the first of several studies of the retrieved camera and was performed immediately after the camera was opened. The emphasis of the analysis was placed upon isolating microorganisms that could be potentially pathogenic for man. Every step in the retrieval of the Surveyor 3 television camera was analyzed for possible contamination sources, including camera contact by the astronauts, ingassing in the lunar and command module during the mission or at splashdown, and handling during quarantine, disassembly, and analysis at the Lunar Receiving Laboratory

Mitchell, F. J.↗

Return-beam vidicon multispectral camera system for ERTS A and B.

This paper describes the return-beam vidicon camera system that RCA is developing for use in the ERTS A and B missions. The major parameters of the two-inch return-beam vidicon camera subsystem are explained, and its performance characteristics are given. The relationship of the three-camera subsystem and the associated ground stations is illustrated. A multispectral aerial photograph is shown which is a simulation of a scene taken on the Apollo 9 mission. The simulated scene was made by the return-beam vidicon camera and a laser-beam image reproducer, and is representative of a typical scene as it would be viewed from space during an ERTS mission.

Miller, B. P.↗

The Nimbus image dissector camera system - An evaluation of its meteorological applications.

Brief description of the electronics and operation of the Nimbus image dissector camera system (IDCS). The geometry and distortions of the IDCS are compared to the conventional AVCS camera on board the operational ITOS and ESSA satellites. The unique scanning of the IDCS provides for little distortion of the image, making it feasible to use a strip grid for the IDCS received in real time by local APT stations. The dynamic range of the camera favors the white end (high reflectance) of the gray scale. Thus, the camera is good for detecting cloud structure and ice features through brightness changes. Examples of cloud features, ice, and snow-covered land are presented. Land features, on the other hand, show little contrast. The 2600 x 2600 km coverage by the IDCS is adequate for the early detection of weather systems which may affect the local area. An example of IDCS coverage obtained by an APT station in midlatitudes is presented.

Sabatini, R. R.↗

On-film optical recording of camera lens settings

An apparatus is described for recording a representation of the camera lens aperture and focus setting on the film of a camera, while the photographic image is being recorded. A data lens is provided between the camera lens and film, by means of which the aperture and focus setting may be determined. The determination is made by measuring both the location and the size of a data image provided by the data lens. The data lens apparatus requires no electrical power, is low in weight, and does not result in an increase in the external dimensions of the camera.

Thompson, R. E.↗

Two-inch Return Beam Vidicon (RBV) multispectral three camera subsystem

A return beam vidicon multispectral three camera subsystem was developed and built as one of the two principal sensor payloads for the ERTS-A and -B missions. The performance of the cameras on ERTS-1 has been excellent, meeting or exceeding all expectations, especially in the area of geometric fidelity and stability. The three cameras are coaligned in the spacecraft to view the same square ground scene but in different spectral bands. When the separate images are processed and superimposed in their respective colors, they provide a single false color image containing the radiometric and cartographic information required for the ERTS system. The three spectral regions covered by the RBV subsystem are the blue-green red, and the near infrared. The three cameras are exposed simultaneously to facilitate registration of the three separate images into the final color composite.