Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building envelope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Carbon-Sequestration Straw Cellulose-Aerogel Gradient Thermal Insulation Material

Green superinsulation materials are essential for net-zero sustainable building envelopes. Realizing such potential is indispensable for simultaneously achieving carbon-sequestration and superinsulation performance. Here, we report the synthesis of a water glass-based silica aerogel exhibiting a thermal conductivity of 17.2 mW/m·K and a high porosity of 92%. Here, we used carbon-sequestration wheat straw fiber to create a gradient cellulose-aerogel composite to improve mechanical stability. The as-prepared gradient composite exhibits a thermal conductivity of 27.1 mW/m·K and a flexural modulus of 824 MPa, while exhibiting superhydrophobicity (water contact angle of 135.4°) for the development of green building insulation materials.

36 MATERIALS SCIENCE↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

United States cool surfaces deployment plan

Solar-reflective building envelope surfaces, such as cool roofs and walls, can be especially helpful in disadvantaged communities that often have poorly insulated older homes, aging or absent air conditioning units, steep utility bills, polluted air, and high vulnerability and exposure to extreme heat. With support from the U.S. Department of Energy, our project seeks to dramatically increase the climate-appropriate deployment of cool surfaces across the United States with an emphasis on their application to disadvantaged communities. First, we sought to identify cool-surface deployment barriers, opportunities, and models by (a) reviewing the history of cool-surface deployment activities, (b) interviewing cool-surface stakeholders, (c) researching successful energy-efficiency/green building deployment models; and (d) interviewing the actors who have implemented these models. Second, we conducted a workshop to engage stakeholders in development of a deployment plan. Third, we asked several U.S. federal agencies (a) how cool surfaces and cool surface stakeholders could support their missions and (b) how agency activities could support cool-surface deployment. Fourth, we identified a set of transformative ideas that form the core of the deployment plan. Transformative ideas include but are not limited to initiatives to (a) launch an educational campaign to make the general public and building professionals aware of how cool roofs and walls exclude unwanted solar heat; (b) create a “Cool Roof Prize” stimulating the development of affordable, high-performance cool asphalt roofing shingles; (c) conduct high-profile, large-scale demonstration programs that bring cool surfaces to disadvantaged heat-vulnerable communities; and (d) support local, regional, and state climate action (heat mitigation) plans with cool surfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-Healing Films for Vacuum Insulation Panels (Final Report)

Vacuum insulation panels (VIPs) have an extremely high thermal resistance of around R35/inch, which makes them ideal for building envelope retrofits and prefabricated construction with space constraints. However, the barrier film that maintains the vacuum and thermal performance of the panel can be easily damaged during transportation, installation, and service life. Oak Ridge National Laboratory (ORNL) has developed a self-healable barrier film for VIPs that instantly self-heals damages caused by punctures. The multi-layer barrier film is manufactured using roll-to-roll (R2R) methods. The self-healing barrier film prevents loss of vacuum in VIPs and maintains the exceptional thermal insulation performance. Enhanced durability of VIP by self-healable barrier film and establishing the commercialization path will increase the use of VIPs, thus reducing overall energy usage of buildings. This project has fine-tuned the slurry chemistry of the self-healing components and transitioned the R2R manufacturing trials from mid-scale lab equipment to large-scale industrial equipment for de-risking the technology for commercialization with our TCF CRADA partner, FLEXcon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Dataset 2024.1 Documentation

Public ResStock datasets provide credible, relevant, and accessible information on energy use and related non-energy metrics to a variety of stakeholders in the residential buildings space. The current public datasets include baseline building characteristics, timeseries (15-minute) energy consumption, and timeseries carbon emissions for the baseline (existing) U.S. housing stock and the U.S. housing stock with 10 "what-if" energy measure packages applied. This report documents a new public ResStock dataset to complement and build upon the existing public datasets. This dataset is specifically intended to be a resource for state and local decision-makers considering options for energy retrofits for their housing stock to reduce carbon emissions, energy use, and/or utility bills. These data consist of housing stock characteristics and modeled full-year energy consumption, carbon emission, energy bill, and energy burden data for the baseline U.S. housing stock as well as the U.S. housing stock with 260 "what-if" energy measure packages applied. These measure packages include measures related to the building envelope, appliances, pools and spas, lighting, water heating, and HVAC (including efficiency improvements and fuel switching with equipment at a range of performance levels) in a variety of combinations. This report provides methodology information on the generation of this dataset and serves as a key part of the dataset's public documentation.

buildings↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

Building America↗

Smart Ventilation Controls Boost Energy Efficiency and Indoor Air Quality

The average American household spends more than $2,200 a year on energy, and heating, ventilating, and air conditioning (HVAC) costs comprise nearly half of the bill. This is one reason why home builders focus on tightening building envelopes to save energy. Yet, limiting the potential for air exchange can negatively impact indoor air quality (IAQ). When outdoor conditions are most extreme during occupied periods, there may be comfort implications from continuing high levels of ventilation during associated weather events. This is true even with heat recovery. To mitigate risks, the Florida Solar Energy Center developed and tested approaches for “smart” ventilation system controls that enable more reliable design, installation, and operation to achieve desired IAQ while also minimizing energy and comfort impacts.

30 DIRECT ENERGY CONVERSION↗

Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Cross-laminated timber buildings are becoming more common in North America, with many numerical studies showing potential energy savings. However, no studies have validated any EnergyPlus heat transfer algorithms or quantified their accuracy in simulating CLT in building envelopes. This study empirically validates the heat flux predictions for each of EnergyPlus's heat transfer algorithms (Conduction Transfer Functions (CTF), Effective Moisture Penetration Depth (EMPD), Conduction Finite Difference (CondFD), and Heat and Moisture Transfer (HAMT)) for two different CLT ply thicknesses with both summer and winter boundary conditions measured in controlled lab experiments. It also evaluates the model sensitivity of heat flux and heating and cooling loads to moisture content. The 1D validation shows that the HAMT model is the most accurate among all algorithms. All EnergyPlus's heat flux predictions are accurate independent of CLT plate thickness for summer conditions. However, the three constant property algorithms (CTF, EMPD, and CondFD) underpredict heat flux throughout the whole day during winter conditions. The 1D sensitivity analysis indicates that elevated moisture content can increase peak heat fluxes through the material by up to 20 %. Finally, the whole building model sensitivity analysis shows increased heating load and slight cooling load variation due to increased moisture content when using constant property models. The analysis shows significantly lower peak thermal demand (7 % lower heating and 6 % lower cooling) and monthly thermal load (8 % less cooling and 6 % less heating) predictions when using HAMT vs a constant property model.

42 ENGINEERING↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Home Energy Upgrades as a Pathway to Home Decarbonization in the US: A Literature Review

This work aims to characterize how home energy upgrade projects and programs in the US have evolved over the past decade. It also identifies what changes are needed to drive expansion of the US energy retrofit market in such a way that addresses carbon emissions from buildings, improves resilience and upgrades the housing stock. This review focuses on whole-home energy upgrades, targeting deep energy retrofit savings of >30%. The topics we cover include trends in home electrification, US and European home energy upgrade programs, energy upgrade measure costs, business economics, and health effects. Key changes in project design noted in this review include: (1) the electrification of dwellings with rapidly improving heat pump systems and low-cost solar photovoltaic technology; and (2) a shift away from high-cost building envelope strategies and towards more traditional home performance/weatherization envelope upgrades. Promising program design strategies covered include: (1) end-use electrification programs; (2) novel financing approaches; (3) the use of carbon-based program and project metrics; and (4) “one-stop shop” programs. Based on the existing market barriers, we suggest that the industry should adopt new project performance metrics. Additionally, market drivers are needed to spur widespread energy upgrades in the US housing stock. Costs must be reduced, and projects designed to appeal to homeowners and contractors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Emulation and detection of physical faults and cyber-attacks on building energy systems through real-time hardware-in-the-loop experiments

The increasing use of remote or mobile access, integrated wearable technologies, data exchange, and cloud-based data analytics in modern smart buildings is steering the building industry towards open communication technologies. The increased connectivity and accessibility could lead to more cyber-attacks in smart buildings. On the other hand, physical faults (e.g., HVAC -heating, ventilation, and air-conditioning faults) may have similar adverse impacts as those from the cyber-attacks on building energy systems, such as occupant discomfort, energy wastage, and equipment downtime. However, current physical behavior-based anomaly detection methods fail to differentiate between cyber-attacks and physical faults in building energy systems. Moreover, the challenge in collecting real-world threat data with ground truth has led researchers to rely on numerical models with user-defined assumptions, which may not accurately reflect real-world conditions due to the lack of in-situ experimental datasets. To address these challenges and gaps, this paper presents a flexible hardware-in-the-loop (HIL) testbed for generating cyber-attack and physical fault datasets and demonstrating threat detection algorithms in a real building automation system (BAS) environment. This testbed combines hardware (i.e., real BAS with local HVAC controllers and a physical network) with software (i.e., high-fidelity models to represent behaviors of building envelope and HVAC energy systems), enabling emulations of realistic threats. Five HIL experiments, including one baseline without any threats, two with physical faults, and two with cyber-attacks, were conducted to generate datasets containing detailed network traffic and system states. A joint classification framework, incorporating a network analyzer and a physical HVAC fault detector, was proposed to automatically detect cyber-physical abnormalities on BAS at both the network and the physical HVAC levels. The network analyzer comprises a conditional random fields (CRF) based command validator and a statistics-based detection strategy. The fault detector employs a weather and schedule-based pattern matching and feature-based principal component analysis (WPM-FPCA) method. Evaluation of the classification using four metrics from the multi-class confusion matrix revealed an average accuracy of 90.2%, recall of 89.7%, precision of 88.5% and F1-score of 89.2%. Finally, these results demonstrate that the proposed joint classification framework can effectively differentiate between specific types of cyber-attacks (e.g., device reinitialization attack, network Denial-of-Service attack) and physical faults (e.g., air handling unit operational fault, cooling coil valve stuck) in real time for improved building energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating indoor thermal resilience of passive and low-power cooling shelters for outdoor workers in India

India’s 231 million outdoor workers are exposed to deadly heat during heat waves. We report results from a simulation-based study that focuses on passive design of cooling shelters for the hot and dry climate zone of India. The goal is to design a cooler-than-outdoor shelter for outdoor workers’ intermittent rest and recovery from heat stress during their arduous outdoor work, to avoid heat-related morbidities and mortality. Expected indoor thermal conditions in low-cost cooling shelters deploying a range of passive designs and low-power active measures are investigated, consistent with the current Indian standards and practices, located in the city of Jodhpur in western India. Heat resilience of the shelter was measured with the predicted reduction of hazardous hours inside the shelter based on the wet-bulb globe temperature (WBGT) and extended heat index. These measures include improving the building envelope, installing cool roofs, using internal thermal mass, and natural ventilation. Additionally, a low-power active measure of using ventilation fans and ceiling fans is explored. EnergyPlus-based simulation results show that simple, commonly available measures, particularly natural ventilation and ceiling fans, achieve the most significant reductions in overheating danger hours, by 22% and 21%, respectively, while more complex or costly passive strategies yield only marginal additional benefits. Moreover, combined measure packages are identified that can reduce the indoor WBGT by 8 to 10 °C, eliminating overheating danger hours. These findings highlight the critical importance of scalable, low-cost, and easily deployable cooling solutions for developing resilient cooling shelters for vulnerable outdoor workers during heat waves in India.

building performance↗

Impact of Space Heating Options on Electricity Rates and Affordability

Electricity prices have increased in many regions of the U.S., with a national average of 18 cents/kWh projected for 2026, up from 16 cents/kWh in 2020. While the increases can be attributed to a number of factors, increasing electricity use in an efficient and strategic manner - with energy efficient building envelope upgrades and high performance HVAC systems - has the potential to increase revenue for utilities without significantly increasing electricity demand, and therefore could help moderate rate increases. This effect has been studied for electric vehicle charging[1] and dual-fuel heat pumps in Minnesota[2]. Leveraging a recently developed system cost methodology and FERC data on utility revenue, spending, and profits, this poster will present the direction and relative magnitude of rate impacts for efficient space heating upgrades in utility balancing areas across the contiguous U.S., using current prices and showing how the rate impacts would evolve under future grid scenarios.

15 GEOTHERMAL ENERGY↗

Effect of Urban Heat Island and Global Warming Countermeasures on Heat Release and Carbon Dioxide Emissions from a Detached House

Urban air temperature rises induced by the urban heat island (UHIE) effect or by global warming (GW) can be beneficial in winter but detrimental in summer. The SCIENCE-Outdoor model was used to simulate changes to sensible heat release and CO 2 emissions from buildings yielded by four UHIE countermeasures and five GW countermeasures. This model can evaluate the thermal condition of building envelope surfaces, both inside and outside. The results showed that water-consuming UHIE countermeasures such as evaporative space cooling and roof water showering provided positive effects (decreasing sensible heat release and CO 2 emissions related to space conditioning) in summer. Additionally, they had no negative (unwanted cooling) effects in winter since they can be turned off in the heating season. Roof greening can provide the greatest space- conditioning CO 2 emissions reductions among four UHIE countermeasures, and it reduces the amount of heat release slightly in the heating season. Since the effect on reducing carbon dioxide (CO 2 ) emissions by UHIE countermeasures is not very significant, it is desirable to introduce GW countermeasures in order to reduce CO 2 emissions. The significance of this study is that it constructed the new simulation model SCIENCE-Outdoor and applied it to show the influence of countermeasures upon both heat release and CO 2 emissions.

54 ENVIRONMENTAL SCIENCES↗

Force-Triggered, Biobased Sealants for Prefabricated Building Components: Toward Improved Efficiency and Performance

The prefabricated building construction industry has made extensive progress in expediting the manufacture of prefabricated components at off-site plants. However, the sealing of joints between these components, which is crucial to ensuring the weatherproofing of the assembly, still represents a labor-intensive, on-site effort that relies on the manual installation of tapes and caulks. Here, to reduce work at the jobsite and improve the airtightness and waterproofness of building envelopes, we developed a sealant that can be installed at the plant on prefab components and have the curing reaction triggered at the jobsite by using microencapsulation technology to separate the reactive agents. A series of force-triggered, high-strength, and fast-curing sealants derived from biobased feedstocks were developed, which consist of a biobased epoxy agent encapsulated in a polymer shell, embedded in a biobased amine curing agent. The shell of the microcapsules allows an effective separation of the reactive species in the one-part sealant, allowing shelf stability to an otherwise fast-curing system as well as improving the hydrophobicity of the whole system. When force activates and breaks the microcapsules, the highly reactive epoxy and amine mix and cure, exhibiting peel strength values of up to 143 ppi (pounds per inch). The hydrophobicity of the sealants allows them to retain up to 94% of the original peel strength after complete submersion in water for 24 h, showcasing the water resistivity of the sealant system. The open-air shelf stability of the sealant complex is demonstrated by the obtention of peel strength values of ∼16 ppi when triggering the curing reaction even after being exposed 8 months to open air and humidity. The successful on-demand triggering of curing reactions and the shelf stability provide efficacy of these force-triggered sealants for installation on prefabricated components, storage for months prior to delivery, and assembly at a jobsite. These force-triggered biobased sealants for prefabricated buildings can result in lower installation time and cost and better performance than tapes and caulks at the jobsite.

biobased↗

Modeling and Validation of a Residential Multi-Functional Variable Refrigerant Flow Heat Pump System with Heat Recovery

To bridge the existing gap in modeling the variable refrigerant flow heat pump systems with heat recovery (VRFHR), we developed a suite of dynamic VRFHR system models in Modelica. These models are specifically tailored for residential multi-functional VRFHR (MF-VRFHR) applications, including space conditioning and domestic hot water (DHW) heating, utilizing both the TIL library for HVAC equipment and the Buildings library for thermal load calculations. The development comprises essential component models, including the newly developed heat recovery unit (HRU), along with system models that integrate the heat pump system and building envelope. These system models accommodate various operational modes such as heating-only, cooling-only, and heating-recovery (including heating-dominant and cooling-dominant) modes. Furthermore, we propose an efficient optimization-based model calibration method that identifies critical model parameters while utilizing a small amount of data obtained from either real systems or manufacturer's specifications. We demonstrate the effectiveness of these models and the proposed calibration method for a MF-VRFHR system installed in Richland, WA. The developed models are calibrated and validated using data collected under different operational modes during both heating and cooling seasons. The results show that the models capture the system dynamics and achieve high accuracy, with the coefficient of the variation of the root-mean-square-error less than 15% for variables such as outdoor unit power consumption, compressor speed, space temperature and DHW temperature. The validated models serve as a reliable representation of the MF-VRFHR system, facilitating the development and validation of optimized controls needed to realize the full benefits of integrated heat pump systems. Future research will utilize these models to develop advanced controls and optimize system performance for improved energy efficiency and demand flexibility.

Modeling, Variable refrigerant flow (VRF) systems,↗