Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Equitable Strategies for Residential Building Energy Efficiency and Electrification in San José, California [Slides]

Hotter summers, heat waves, wildfires, and droughts are already affecting San Jose residents, with historically marginalized communities impacted first and worst. The City of San Jose has ambitious goals to make the city climate-neutral by 2030 and serve as an example for cities to accelerate climate action around the world. Electrifying and decarbonizing residential buildings are important priorities to achieve San Jose's plans to reach carbon neutrality while enabling residents to live the "Good Life 2.0" - a vision that aligns with community-identified priorities of safety, health, freedom, community, and positive experiences. This technical assistance built upon the Electrify San Jose: Framework for Existing Building Electrification to identify actionable strategies to make single- and multi-family buildings both energy-efficient and all-electric. This report is intended to provide the San Jose Climate Smart team and their partners with relevant data, insights, and actionable analysis to aid in-depth and nuanced engagements with key stakeholders. In particular, the findings in this report highlight opportunities and challenges for San Jose City Council, residents, building owners, developers, financial institutions, and utility partners instrumental in building support and earning buy-in for energy efficiency and electrification upgrades in existing buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

North American Overview - Heat Pumps Role in Buildings Energy Efficiency Improvement

A brief overview of the situation in North America regarding buildings energy use and the current and projected heat pump market is presented. R&D and deployment strategies for heat pumps, and the impacts of the housing market and efficiency regulations on the heating and cooling equipment market are summarized as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy 101: Energy Efficient Commercial Buildings

Learn how commercial buildings can incorporate whole-building design to save energy and money while enhancing performance and comfort. This video highlights several energy-saving features of the Research Support Facility at the Energy Department's National Renewable Energy Laboratory-a model for high-performance office building design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selecting a Control Strategy for Plug and Process Loads

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand-side solutions in the US building sector could achieve deep emissions reductions and avoid over $100 billion in power sector costs

Buildings are energy-intensive and a primary source of US end-use sector carbon emissions. Although building emissions today are 25% below their 2005 peak, far deeper reductions are needed to reach the US 2050 net-zero emissions goal. However, plausible decarbonization pathways that consider both buildings and their interactions with the power grid remain poorly understood. Here, we couple detailed modeling of building energy use and the grid to quantify building decarbonization potential and associated grid impacts. We find up to a 91% reduction in building CO 2 emissions from 2005 levels by 2050 using a portfolio of building efficiency, demand flexibility, and electrification measures alongside rapid grid decarbonization. Building efficiency and flexibility could generate up to $107 billion in annual power system cost savings by 2050, offsetting over a third of the incremental cost of full grid decarbonization. Our results underscore multiple benefits of demand-side solutions for deep decarbonization of US buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing Building Energy Efficiency through Advanced Sizing and Dispatch Methods for Energy Storage

Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.

Yu, Mingyung↗

Opaque Envelopes: Pathway to Building Energy Efficiency and Demand Flexibility: Key to a Low-Carbon, Sustainable Future

The opaque envelope - the barrier that helps maintain comfortable indoor conditions regardless of prevailing outdoor conditions - is the single largest contributor to primary energy use in residential and commercial buildings. Residential and commercial buildings comprise 39% of total U.S. primary energy use [1]. The opaque envelope affects 25% of building energy use, or 10% of total U.S. primary energy use [2]. High-performance opaque envelope technologies, therefore, have substantial potential to reduce energy use in both new construction and existing buildings. Retrofits are particularly crucial to realizing the energy savings potential of the opaque envelope because nearly 85% of residential and 55% of commercial buildings that exist today will still exist in 2050 [1]. Building envelope performance is also important for occupant comfort, productivity, health, and well-being. Improving the energy performance of the opaque envelope in U.S. buildings is critical to achieving aggressive cli- mate goals that support a clean energy economy and an equitable energy future for all Americans. By reducing total building energy use and improving energy efficiency, envelope research and development (R&D) will have a significant impact on how low-carbon buildings can mitigate climate change.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.

decomposition↗

U.S. Department of Energy Solar Decathlon: Challenging Students to Build Energy Efficient, Cost-Effective, and Attractive Solar-Powered Houses

The U.S. Department of Energy Solar Decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The winner of the competition is the team that best blends affordability, consumer appeal, and design excellence with optimal energy production and maximum efficiency. The paper discusses the solutions developed forthe event. We believe that the solutions implemented for Solar Decathlon 2011 represent current trends and that by analyzing, critiquing, and exposing the solutions pursued, the industry can become better suited to address challenges of the future. Constructing a solar community using high-efficiency design and unique materials while remaining code compliant, safe, and effective results insolutions that are market relevant, important, and interesting to the industry as a whole.

14 SOLAR ENERGY↗

Building Science Education for Solar Decathlon: Emissions and the Built Environment [Slides]

The Solar Decathlon Building Science Education series is designed to educate students and working professionals on building science principles that are paramount to the successful design of high-performance, energy-efficient buildings. Instructional content is presented in modules, covering specific topics. Altogether, this series aims to educate viewers on: 1) where/how energy is used in buildings; 2) how to define zero energy buildings; 3) how to apply the fundamentals of thermodynamics to building envelope design; 4) how to explain the science of how/why buildings use energy; 5) how to apply this knowledge to design comfortable energy efficient buildings. Students and working professionals can use this educational information at no cost to complement academic curriculum and continuing education activities. This is Module 7 which focuses on embodied environmental carbon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart technologies enable homes to be efficient and interactive with the grid

Oak Ridge National Laboratory researchers compare two different approaches to test how advanced, energy-efficient building technologies such as smart thermostats, heat pump water heaters, and advanced heat pump HVAC (heating, ventilation and air conditioning) can be optimized within a home and connected at a neighborhood-scale load to a community microgrid in the Alabama Power Smart Neighborhood located in Hoover. Working with Southern Company and Alabama Power, ORNL researchers are pioneering that future where smart homes and smart neighborhoods can benefit both homeowners and utilities, by reducing energy consumption by 44% and peak demand by 34%.This project is one of two neighborhoods in the U.S Department of Energy’s (DOE’s) Connected Neighborhood project, supported by Building Technologies Office , where ORNL researchers leverages DOE investment in micro-grids and responsive, flexible building loads research to improve grid reliability – a goal of DOE’s Grid-interactive Efficient Buildings (GEB) Initiative. Researchers control the neighborhood and microgrid to enable utilities achieve their desired load and cost profiles while ensuring the comfort of homeowners in the Smart Neighborhood. This transactive control approach maximizes the utilization of technical resources of the microgrid and controllable loads, while reducing costs for both the homeowners and Alabama Power. These tests partially seek to determine a more precise range of tolerance with respect to occupant comfort as researchers work to facilitate customer acceptance and perception of new building technologies that enable energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Compressor Selection and Equipment Sizing for Cold Climate Heat Pumps

In order to limit heating capacity degradation at -25 C (-13 F) ambient to 25%, compared to the nominal rating point capacity at 8.3 C (47 F), an extensive array of design and sizing options were investigated, based on fundamental equipment system modeling and building energy simulation. Sixteen equipment design options were evaluated in one commercial building and one residential building, respectively in seven cities. The energy simulation results were compared to three baseline cases: 100% electric resistance heating, a 9.6 HSPF single-speed heat pump unit, and 90% AFUE gas heating system. The general recommendation is that variable-speed compressors and tandem compressors, sized such that their rated heating capacity at a low speed matching the building design cooling load, are able to achieve the capacity goal at low ambient temperatures by over-speeding, for example, a home with a 3.0 ton design cooling load, a tandem heat pump could meet this cooling load running a single compressor, while running both compressors to meet heating load at low ambient temperatures in a cold climate. Energy savings and electric resistance heat reductions vary with building types, energy codes and climate zones. Oversizing a heat pump can result in larger energy saving in a less energy efficient building and colder regions due to reducing electric resistance heating. However, in a more energy-efficient building or for buildings in warmer climates, one has to consider balance between reduction of resistance heat and addition of cyclic loss.

Building Energy Simulation↗

Walmart - Saving Energy, Saving Money Through Comprehensive Retrofits, Commercial Building Energy Efficiency (Fact Sheet); Energy Efficiency & Renewable Energy (EERE)

Walmart partnered with the U.S. Department of Energy (DOE) in 2009 to develop and demonstrate energy retrofits for existing buildings. The goal was to reduce energy consumption by at least 30% versus ASHRAE Standard 90.1-2007, as part of DOE's Commercial Building Partnerships (CBP) Program. The project presented here, the retrofit of a 213,000 square foot store in Centennial, Colorado, withefficiency measures across multiple building systems, is part of Walmart's ongoing environmental sustainability program, which originated in 2005.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗