Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Effect of Background Emissivity on Gas Detection in Thermal Hyperspectral Imagery

Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temper- ature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on net chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on the background emissivity. It then describes what conditions on the background emissivity have inhibiting effects on the net chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the Adaptive Matched Filter using four chemicals and three distinct background emissivities. Two chemicals (Carbontetrachloride and Tetraflourosilane) in the analysis had a very strong relationship with the background emissivities: they exhibited absorbance over a small range of wavenumbers and the background emissivities showed a consistent ordering at these wavenumbers. Analysis of simulated hyperspectral images containing these chemicals showed complete agreement with the analysis of the physics-based model that described when the background emissivities would have inhibiting effects on gas detection. The other chemicals considered (Ammonia and Tributylphosphate) exhibited very complex absorbance structure across the longwave infrared spectrum. Analysis of images containing these chemicals revealed that the the analysis of the physics-based model did not hold completely for these complex chemicals but did suggest that gas detection was dominated by their dominant absorbance features. These results provide some explanation of the effect of the background emissivity on gas detection and a more general exploration of gas absorbance/background emissivity variability and their effects on gas detection is warranted. i

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Current Background Noise Sources and Levels in the NASA Ames 40- by 80-Foot Wind Tunnel: A Status Report

Background noise measurements were made of the acoustic environment in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The measurements were acquired subsequent to the 40x80 Aeroacoustic Modernization Project, which was undertaken to improve the anechoic characteristics of the 40x80's closed test section as well as reduce the levels of background noise in the facility. The resulting 40x80 anechoic environment was described by Soderman et. al., and the current paper describes the resulting 40x80 background noise, discusses the sources of the noise, and draws comparisons to previous 40x80 background noise levels measurements. At low wind speeds or low frequencies, the 40x80 background noise is dominated by the fan drive system. To obtain the lowest fan drive noise for a given tunnel condition, it is possible in the 40x80 to reduce the fans' rotational speed and adjust the fans' blade pitch, as described by Schmidtz et. al. This idea is not new, but has now been operationally implemented with modifications for increased power at low rotational speeds. At low to mid-frequencies and at higher wind speeds, the dominant noise mechanism was thought to be caused by the surface interface of the previous test section floor acoustic lining. In order to reduce this noise mechanism, the new test section floor lining was designed to resist the pumping of flow in and out of the space between the grating slats required to support heavy equipment. In addition, the lining/flow interface over the entire test section was designed to be smoother and quieter than the previous design. At high wind speeds or high frequencies, the dominant source of background noise in the 40x80 is believed to be caused by the response of the in-flow microphone probes (required by the nature of the closed test section) to the fluctuations in the freestream flow. The resulting background noise levels are also different for probes of various diameters and types. The inflow microphone support strut is also a source of background noise but this source's impact may be minimized by careful design of the strut. In the present paper, the mechanisms mentioned above are discussed in detail. Their frequency and velocity ranges of dominance are defined and the differences between past and current facility background noise levels are presented. This paper gives valuable information for those wishing to make acoustic measurements in the 40x80. With this report and an estimate of the noise levels produced by the noise source of interest, it should be possible to determine the signal-to-noise ratios and measurement locations to successfully perform aeroacoustic testing in the NASA Ames Research Center's 40- by 80-Foot Wind Tunnel.

Allen, Christopher S.↗

Background Maritime Aerosol: Their Optical Thickness and Scattering Properties

The effect of human induced change in the aerosol concentration and properties, or the aerosol response to climate change (e.g. droughts producing fires or dust) should be measured relative to a "background aerosol". How to define this background aerosol, so that it is both measurable and useful? Here we use 10 stations located in the Pacific, Atlantic and Indian Oceans to answer this question. Using a data set of the spectral optical thickness measured by the Aerosol Robotic network (AERONET), extending 1-3 years, we find the background conditions for these stations. The oceanic background aerosol is the result of ocean emission and spray, and some residual long lived continental aerosol. Its source is very broadly spread and is expected to vary little in time. Pollution or dust sources are from specific locations, emitted and transported to the measuring site in specific combination of meteorological conditions. Therefore they are expected to vary with time. It follows that the background aerosol can be identified as the median for conditions with small variations. To define the background we compute the median of N consequent measurements. We use N=50 that in average cloudy conditions corresponds to 2-3 days of measurements and N=100 (4-5 days). Most high polluted or dusty conditions correspond to data sequences with high standard deviation (greater than 0.02 in optical thickness) and are excluded. From the remaining N point running medians with low standard deviations we derive again the median. This excludes those rare cases of pollution or dust that is stable during the N measurements. The results show that the background aerosol over the Pacific Ocean is characterize by optical thickness of 0.055 at 500 nm and Angstrom exponent of 0.74. Over the Atlantic Ocean the values are 0.070 and 1.1 respectively, with little influence of the assumed value of N (50 or 100). The derivation of the background uses 20,000 and 5000 medians respectively that passed the criteria. The contribution of coarse and fine aerosol to the background aerosol is also calculated.

Kaufman, Yoram J.↗

Subspace-based Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing

A subspace-based form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique is based on an eigenvalue decomposition of the background noise cross-spectral matrix. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels, and when background data do not match between measurements. Experimental results show limited success in recovering signal behavior for data in which conventional background subtraction fails. The results also demonstrate the subspace subtraction technique's ability to maintain a physical coherence relationship in the modified cross-spectral matrix. Deconvolution results from microphone phased array data indicate that array integration methods are largely insensitive to subtraction type, and that background subtraction with appropriate background data is an effective alternative to diagonal removal.

deconvolution↗

Review of Monte Carlo simulations for backgrounds from radioactivity

For all experiments dealing with the rare event searches (neutrino, dark matter, neutrino-less double-beta decay), the reduction of the radioactive background is one of the most important and difficult tasks. There are basically two types of background, electron recoils and nuclear recoils. The electron recoil background is mostly from the gamma rays through the radioactive decay. The nuclear recoil background is from neutrons from spontaneous fission, (α, n) reactions and muoninduced interactions (spallations, photo-nuclear and hadronic interaction). The external gammas and neutrons from the muons and laboratory environment, can be reduced by operating the detector at deep underground laboratories and by placing active or passive shield materials around the detector. The radioactivity of the detector materials also contributes to the background; in order to reduce it a careful screening campaign is mandatory to select highly radio-pure materials. In this review I present the status of current Monte Carlo simulations aimed to estimate and reproduce the background induced by gamma and neutron radioactivity of the materials and the shield of rare event search experiment. For the electromagnetic background a good level of agreement between the data and the MC simulation has been reached by the XENON100 and EDELWEISS experiments, using the GEANT4 toolkit. For the neutron background, a comparison between the yield of neutrons from spontaneous fission and (α, n) obtained with two dedicated softwares, SOURCES-4A and the one developed by Mei-Zhang-Hime, show a good overall agreement, with total yields within a factor 2 difference. The energy spectra from SOURCES-4A are in general smoother, while those from MZH presents sharp peaks. The neutron propagation through various materials has been studied with two MC codes, GEANT4 and MCNPX, showing a reasonably good agreement, inside 50% discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating radiological background using imaging spectroscopy

Optical imaging spectroscopy is investigated as a method to estimate radiological background by spectral identification of soils, sediments, rocks, minerals and building materials derived from natural materials and assigning tabulated radiological emission values to these materials. Radiological airborne surveys are undertaken by local, state and federal agencies to identify the presence of radiological materials out of regulatory compliance. Detection performance in such surveys is determined by (among other factors) the uncertainty in the radiation background; increased knowledge of the expected radiation background will improve the ability to detect low-activity radiological materials. Radiological background due to naturally occurring radiological materials (NORM) can be estimated by reference to previous survey results, use of global 40K, 238U, and 232Th (KUT) values, reference to existing USGS radiation background maps, or by a moving average of the data as it is acquired. Each of these methods has its drawbacks: previous survey results may not include recent changes, the global average provides only a zero-order estimate, the USGS background radiation map resolutions are coarse and are accurate only to 1 km – 25 km sampling intervals depending on locale, and a moving average may essentially low pass filter the data to obscure small changes in radiation counts. Imaging spectroscopy from airborne or spaceborne platforms can offer higher resolution identification of materials and background, as well as provide imaging context information. AVIRIS hyperspectral image data is analyzed using commercial exploitation software to determine the usefulness of imaging spectroscopy to identify qualitative radiological background emissions when compared to airborne radiological survey data.

background radiation estimation↗

Computational Assessment of Naturally Occurring Neutron and Photon Background Radiation Produced by Extraterrestrial Sources

In this study, a computational assessment of the variation in terrestrial neutron and photon background from extraterrestrial sources is presented. The motivation of this assessment is to evaluate the practicality of developing a tool or database to estimate background in real time (or near–real time) during an experimental measurement or to even predict the background for future measurements. The extraterrestrial source focused on during this assessment is naturally occurring galactic cosmic rays (GCRs). The MCNP6 transport code was used to perform the computational assessment. However, the GCR source available in MCNP6 was not used. Rather, models developed and maintained by NASA were used to generate the GCR sources. The largest variation in both neutron and photon background spectra was found to be caused by changes in elevation on Earth's surface, which can be as large as an order of magnitude. All other perturbations produced background variations on the order of a factor of 3 or less. The most interesting finding was that ~80% and 50% of terrestrial background neutrons and photons, respectively, are generated by interactions in Earth's surface and other naturally occurring and man-made objects near a detector of particles from extraterrestrial sources and their progeny created in Earth's atmosphere. In conclusion, this assessment shows that it will be difficult to estimate the terrestrial background from extraterrestrial sources without a good understanding of a detector's surroundings. Therefore, estimating or predicting background during a measurement environment like a mobile random search will be difficult.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of residue background events in direct dark matter detection experiments on the determination of the WIMP mass

In the earlier work on the development of a model-independent data analysis method for determining the mass of Weakly Interacting Massive Particles (WIMPs) by using measured recoil energies from direct Dark Matter detection experiments directly, it was assumed that the analyzed data sets are background-free, i.e., all events are WIMP signals. In this article, as a more realistic study, we take into account a fraction of possible residue background events, which pass all discrimination criteria and then mix with other real WIMP-induced events in our data sets. Our simulations show that, for the determination of the WIMP mass, the maximal acceptable fraction of residue background events in the analyzed data sets of O(50) total events is ∼ 20%, for background windows of the entire experimental possible energy ranges, or in low energy ranges; while, for background windows in relatively higher energy ranges, this maximal acceptable fraction of residue background events can not be larger than ∼ 10%. For a WIMP mass of 100 GeV with 20% background events in the windows of the entire experimental possible energy ranges, the reconstructed WIMP mass and the 1σ statistical uncertainty are ∼ 97GeV{sup +61%}{sub −35%} ( ∼ 94GeV{sup +55%}{sub −33%} for background-free data sets)

79 ASTRONOMY AND ASTROPHYSICS↗

Gravitational wave background from binary systems

Basic aspects of the background of gravitational waves and its mathematical characterization are reviewed. The spectral energy density parameter {Omega}(f), commonly used as a quantifier of the background, is derived for an ensemble of many identical sources emitting at different times and locations. For such an ensemble, {Omega}(f) is generalized to account for the duration of the signals and of the observation, so that one can distinguish the resolvable and unresolvable parts of the background. The unresolvable part, often called confusion noise or stochastic background, is made by signals that cannot be either individually identified or subtracted out of the data. To account for the resolvability of the background, the overlap function is introduced. This function is a generalization of the duty cycle, which has been commonly used in the literature, in some cases leading to incorrect results. The spectra produced by binary systems (stellar binaries and massive black hole binaries) are presented over the frequencies of all existing and planned detectors. A semi-analytical formula for {Omega}(f) is derived in the case of stellar binaries (containing white dwarfs, neutron stars or stellar-mass black holes). Besides a realistic expectation of the level of background, upper and lower limits are given, to account for the uncertainties in some astrophysical parameters such as binary coalescence rates. One interesting result concerns all current and planned ground-based detectors (including the Einstein Telescope). In their frequency range, the background of binaries is resolvable and only sporadically present. In other words, there is no stochastic background of binaries for ground-based detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Visual-Attention-Based Background Modeling for Detecting Infrequently Moving Objects

Motion is one of the most important cues to separate foreground objects from the background in a video. Using a stationary camera, it is usually assumed that the background is static, while the foreground objects are moving most of the time. However, in practice, the foreground objects may show infrequent motions, such as abandoned objects and sleeping persons. Meanwhile, the background may contain frequent local motions, such as waving trees and/or grass. Such complexities may prevent the existing background subtraction algorithms from correctly identifying the foreground objects. We propose a new approach that can detect the foreground objects with frequent and/or infrequent motions. Specifically, we use a visual-attention mechanism to infer a complete background from a subset of frames and then propagate it to the other frames for accurate background subtraction. Furthermore, we develop a feature-matching-based local motion stabilization algorithm to identify frequent local motions in the background for reducing false positives in the detected foreground. The proposed approach is fully unsupervised, without using any supervised learning for object detection and tracking. Extensive experiments on a large number of videos have demonstrated that the proposed approach outperforms the state-of-the-art motion detection and background subtraction methods in comparison.

42 ENGINEERING↗

Techniques to improve the accuracy of noise power spectrum measurements in digital x-ray imaging based on background trends removal

Purpose: Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. Extensive works have been conducted to achieve accurate and precise measurement of NPS. One approach to improve the accuracy of the NPS measurement is to reduce the statistical variance of the NPS results by involving more data samples. However, this method is based on the assumption that the noise in a radiographic image is arising from stochastic processes. In the practical data, the artifactuals always superimpose on the stochastic noise as low-frequency background trends and prevent us from achieving accurate NPS. The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems. Methods: In order to achieve the optimal background detrending technique for NPS estimate, four methods for artifactuals removal were quantitatively studied and compared: (1) Subtraction of a low-pass-filtered version of the image, (2) subtraction of a 2-D first-order fit to the image, (3) subtraction of a 2-D second-order polynomial fit to the image, and (4) subtracting two uniform exposure images. In addition, background trend removal was separately applied within original region of interest or its partitioned sub-blocks for all four methods. The performance of background detrending techniques was compared according to the statistical variance of the NPS results and low-frequency systematic rise suppression. Results: Among four methods, subtraction of a 2-D second-order polynomial fit to the image was most effective in low-frequency systematic rise suppression and variances reduction for NPS estimate according to the authors' digital x-ray system. Subtraction of a low-pass-filtered version of the image led to NPS variance increment above low-frequency components because of the side lobe effects of frequency response of the boxcar filtering function. Subtracting two uniform exposure images obtained the worst result on the smoothness of NPS curve, although it was effective in low-frequency systematic rise suppression. Subtraction of a 2-D first-order fit to the image was also identified effective for background detrending, but it was worse than subtraction of a 2-D second-order polynomial fit to the image according to the authors' digital x-ray system. Conclusions: As a result of this study, the authors verified that it is necessary and feasible to get better NPS estimate by appropriate background trend removal. Subtraction of a 2-D second-order polynomial fit to the image was the most appropriate technique for background detrending without consideration of processing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background based Gaussian mixture model lesion segmentation in PET

Purpose: Quantitative {sup 18}F-fluorodeoxyglucose positron emission tomography is limited by the uncertainty in lesion delineation due to poor SNR, low resolution, and partial volume effects, subsequently impacting oncological assessment, treatment planning, and follow-up. The present work develops and validates a segmentation algorithm based on statistical clustering. The introduction of constraints based on background features and contiguity priors is expected to improve robustness vs clinical image characteristics such as lesion dimension, noise, and contrast level. Methods: An eight-class Gaussian mixture model (GMM) clustering algorithm was modified by constraining the mean and variance parameters of four background classes according to the previous analysis of a lesion-free background volume of interest (background modeling). Hence, expectation maximization operated only on the four classes dedicated to lesion detection. To favor the segmentation of connected objects, a further variant was introduced by inserting priors relevant to the classification of neighbors. The algorithm was applied to simulated datasets and acquired phantom data. Feasibility and robustness toward initialization were assessed on a clinical dataset manually contoured by two expert clinicians. Comparisons were performed with respect to a standard eight-class GMM algorithm and to four different state-of-the-art methods in terms of volume error (VE), Dice index, classification error (CE), and Hausdorff distance (HD). Results: The proposed GMM segmentation with background modeling outperformed standard GMM and all the other tested methods. Medians of accuracy indexes were VE <3%, Dice >0.88, CE <0.25, and HD <1.2 in simulations; VE <23%, Dice >0.74, CE <0.43, and HD <1.77 in phantom data. Robustness toward image statistic changes (±15%) was shown by the low index changes: <26% for VE, <17% for Dice, and <15% for CE. Finally, robustness toward the user-dependent volume initialization was demonstrated. The inclusion of the spatial prior improved segmentation accuracy only for lesions surrounded by heterogeneous background: in the relevant simulation subset, the median VE significantly decreased from 13% to 7%. Results on clinical data were found in accordance with simulations, with absolute VE <7%, Dice >0.85, CE <0.30, and HD <0.81. Conclusions: The sole introduction of constraints based on background modeling outperformed standard GMM and the other tested algorithms. Insertion of a spatial prior improved the accuracy for realistic cases of objects in heterogeneous backgrounds. Moreover, robustness against initialization supports the applicability in a clinical setting. In conclusion, application-driven constraints can generally improve the capabilities of GMM and statistical clustering algorithms.

60 APPLIED LIFE SCIENCES↗

Determining Cs-137 Background Body Burdens for Wild Pigs at Savannah River Site

In Gaines and Novak, an effective method for determining the background 137 Cs body burden for the white-tailed deer population on the SRS was developed, using data collected during public hunts combined with gamma overflight data to determine the areas contaminated by site activities. However, a background 137 Cs body burden for the wild pigs present on the SRS has not been developed to date. In this work, we applied the Gaines and Novak methods to determine the 137 Cs background concentration in wild pigs. The determination of a site-specific home range for wild pigs on SRS with establishing background hunt compartments for calculating the background body burdens of 137 Cs resulted in an upper bound concentration in wild pigs on SRS of 1.97 pCi/g. This value bounds 95% of the possible 137 Cs contamination value for wild pigs from the background compartments with 95% confidence. Therefore, it is recommended that 1.97 pCi/g be used in the SRS Hunter Dose Tracking System as the background 137 Cs concentration for wild pigs on SRS. This concentration should be decay corrected from the year 2014. It is also recommended that this assessment of background concentrations in SRS wild pigs (and whitetailed deer) be performed at least every five years.

59 BASIC BIOLOGICAL SCIENCES↗

Cosmic Supernova Neutrino and Gamma-Ray Backgrounds in the MeV Regime

Cosmic multimessenger backgrounds include relic diffuse components created in the early universe and contributions from individual sources. Here, we study both type Ia supernovae (SNe Ia) and core-collapse supernovae (CCSNe) contributions to the diffuse neutrino and gamma-ray backgrounds in the MeV regime referred to as DSNB and DSGB respectively. We show that the diffuse SN Ia background is 10 6 times lower (for $\overline{v}_e$) than the CCSN background making it negligible. Our predicted DSNB $\overline{v}_e$ flux at earth in the 19.3–32 MeV regime is 0.36 ν cm -2 s -1 . We also find that the DSNB flux in the energy range from 11.3 to 32 MeV varies by +29% with a change in the SFRD model from Madau & Fragos which yielded a minimum predicted flux, to the extragalactic background light reconstruction model (maximum predicted flux). The diffuse SN Ia gamma-ray background and its dependence on the progenitor supernova delay time distribution are also evaluated. Furthermore, we address the origin of the CGB (Cosmic Gamma-ray Background) in the 0.1–7 MeV regime by adding contributions from sources such as SNe Ia, CCSNe, radio-quiet Active Galactic Nuclei, Flat spectrum radio quasars (FSRQs) and Neutron star—neutron star mergers. We find that our modeled background (including uncertainties) matches the observed CGB above 1.0 MeV, but is a factor ≈2 lower than the observed flux in the 0.1–1.0 MeV range, highlighting the need for future MeV missions to establish the CGB spectrum more reliably, and to possibly identify additional sources or even source classes in the underexplored MeV band.

79 ASTRONOMY AND ASTROPHYSICS↗

Background Noise Reduction Using Adaptive Noise Cancellation Determined by the Cross-Correlation

Background noise due to flow in wind tunnels contaminates desired data by decreasing the Signal-to-Noise Ratio. The use of Adaptive Noise Cancellation to remove background noise at measurement microphones is compromised when the reference sensor measures both background and desired noise. The technique proposed modifies the classical processing configuration based on the cross-correlation between the reference and primary microphone. Background noise attenuation is achieved using a cross-correlation sample width that encompasses only the background noise and a matched delay for the adaptive processing. A present limitation of the method is that a minimum time delay between the background noise and desired signal must exist in order for the correlated parts of the desired signal to be separated from the background noise in the crosscorrelation. A simulation yields primary signal recovery which can be predicted from the coherence of the background noise between the channels. Results are compared with two existing methods.

Spalt, Taylor B.↗

Advanced Background Subtraction Applied to Aeroacoustic Wind Tunnel Testing

An advanced form of background subtraction is presented and applied to aeroacoustic wind tunnel data. A variant of this method has seen use in other fields such as climatology and medical imaging. The technique, based on an eigenvalue decomposition of the background noise cross-spectral matrix, is robust against situations where isolated background auto-spectral levels are measured to be higher than levels of combined source and background signals. It also provides an alternate estimate of the cross-spectrum, which previously might have poor definition for low signal-to-noise ratio measurements. Simulated results indicate similar performance to conventional background subtraction when the subtracted spectra are weaker than the true contaminating background levels. Superior performance is observed when the subtracted spectra are stronger than the true contaminating background levels. Experimental results show limited success in recovering signal behavior for data where conventional background subtraction fails. They also demonstrate the new subtraction technique's ability to maintain a proper coherence relationship in the modified cross-spectral matrix. Beam-forming and de-convolution results indicate the method can successfully separate sources. Results also show a reduced need for the use of diagonal removal in phased array processing, at least for the limited data sets considered.

Bahr, Christopher J.↗

SIMULATION OF RADIATION BACKGROUNDS ASSOCIATED WITH NUCLEAR DIAGNOSTICS IN THE NATIONAL IGNITION FACILITY

Experiments resulting in a significant neutron yield are scheduled to start in 2010 at the National Ignition Facility (NIF). Several experiments utilizing Tritium-Hydrogen-Deuterium (THD) and Deuterium-Tritium (DT) targets are scheduled as part of the National Ignition Campaign (NIC). A wide range of diagnostics will be used to measure several parameters of implosion such as the core and fuel shape, temperatures and densities, and neutron yield. Accurate evaluations of the neutron and gamma backgrounds are important for several diagnostics, such as the High Energy X-ray Imager (HEXRI) and Neutron-Time-Of-Flight (nTOF). Several sources of neutron and gamma backgrounds will impact the accuracy of the diagnostics measurements. Fusion neutrons generated by fuel burn and secondary neutrons resulting from the fusion neutrons interaction with structures present inside and outside the Target Chamber (TC) contribute to the neutron background. In the meantime, X-rays emitted from the implosion, X-rays resulting from Laser Plasma Interaction (LPI) of NIF beams with the hohlraum, and gamma-rays induced by neutron interactions with different structures inside and outside the TC contribute to the gamma background. A detailed model has been developed of the NIF facility and all structures inside the TC. Several Monte-Carlo simulations were performed to identify the expected signal-to- background ratios at several potential locations for the HEXRI and nTOF diagnostics. Gamma backgrounds associated with HEXRI were significantly reduced by using a tungsten collimator. The collimator resulted in the reduction of the gamma background at the HEXRI scintillator by more than an order of magnitude during the first 40 ns following a THD shot. The nTOF20 detectors inside the Neutron Spectrometry room are exposed to low levels of neutron and gamma background during yield shots.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiogenic and muon-induced backgrounds in the LUX dark matter detector

The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is (2.6±0.2 stat ±0.4 sys ) ×10 -3 events keV$ ee\atop{-1}$ kg -1 day -1 in a 118 kg fiducial volume. The observed background rate is (3.6±0.4 stat )×10 -3 events keV$ ee\atop{-1}$ kg -1 day -1 , consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗