Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BRASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-E-P-32: Adapting An MMLC to a Conventional Linac to Perform Stereotactic Applications

Purpose: Micro-MLCs minimizes beam scalloping effects caused by conventional-MLCs and facilitates conformal dynamic treatment delivery. But their effect on dosimetric parameters require careful investigations. Physical and dosimetric parameters and Linac mechanical stability with mMLC (net weight 30 Kg) attached to the gantry are to be investigated. Moreover, output study along with recommended jaws offsets are studied. Adaptation of an mMLC to our 16-years old conventional Linac is investigated in this work Methods: BrainLab mMLC (m3) mounted in a detachable chassis to the Philips SL-15 Linac (30kg). Gantry and collimator spoke shots measurements are made using a calibrated film in a solid phantom and compared with pin-point measurements. Leaf penumbra, transmission, leakage between the leaves, percentage depth dose (PDD) are measured using IBA pin-point ion chamber at 6 and 10 MV. For output measurements (using brass build-up cap), jaws are modified continuously regarding to m3-fields while output factor are compared with fixed jaws situation, while the mMLC leaf configuration is modified for different m3-fields Results: Mean transmission through leaves is 1.9±0.1% and mean leakage between leaves is 2.8±0.15%. Between opposing leaves abutting along the central beam-axis mean transmission is 15±3%, but it is reduced to 4.5±0.6% by moving the abutment position 4.5cm off-axis. The penumbra was sharper for m3 -fields than jaws-fields (maximum difference is 1.51±0.2%). m3-fields PDD show ∼3% variation from those of jaws-fields. m3-fields output factors show large variations (<4%) from Jaws defined fields. Output for m3-rectangular fields show slight variation in case of leaf-end&leaf-side as well as X-jaw&Y-jaw exchange. Circular m3-fields output factors shows close agreement with their corresponding square jaws-defined fields using 2mm Jaws offsets, If jaws are retracted to m3 limits, differences become <5%. Conclusion: BrainLab m3 is successfully adapted to our 16 old Philips-SL-15 Linac. Dosimetric properties should be taken into account for treatment planning considerations.

60 APPLIED LIFE SCIENCES↗

SU-E-T-415: Experimental Determination of the Relative Stopping Power of TRUFILL N-BCA Liquid Embolic System in a Clinical Proton Beam

Purpose: Patients who undergo n-BCA glue embolization as part of treatment for AVMs are later referred for proton therapy. Knowing the relative stopping power of the glue accurately allows us to perform accurate dose calculations. In this study we experimentally determine the relative stopping power of an n-BCA mixture in a 126 MeV and 149.6 MeV proton beams. Methods: One unit of the TRUFILL™ n-BCA liquid embolic system consists of 1g unit of n-BCA, 1g unit of Tantalum powder and one 10mL vial of Ethiodized oil. The physician mixed 3:1 Ethiodized oil to n-BCA. Five units (20cc) of the n-BCA liquid embolic glue were prepared and placed in a 6cm x 3cm x3cm Lucite container. The container was placed in front of a water tank in the proton beam path. A diamond detector (active volume 0.004mm3) was used to measure distal edge of depth dose of a modulated 126 MeV proton beam collimated using a 3cm brass aperture. The procedure was repeated with a container carrying the same amount of water placed in front of the water tank. The difference in the depth dose measured with glue and with water was used to determine the relative stopping power of the glue. The same determination was done earlier at 149.6 MeV using a different smaller sample (4cc) of n-BCA. Results: The relative stopping power of this particular n-BCA mixture was determined to be 1.06 at both 126 MeV and 149.6 MeV. We are working on obtaining the composition data of the n-BCA glue so we can perform Monte Carlo calculations. Conclusion: Accurate value of the stopping power of the n-BCA glue in the proton beam was determined to be 1.06. It will improve the accuracy of dose calculations in proton radiosurgery procedures on AVM patients with n-BCA embolization.

60 APPLIED LIFE SCIENCES↗

Effect of atmosphere on collinear double-pulse laser-induced breakdown spectroscopy

Double pulse laser induced breakdown spectroscopy (DP-LIBS) has been shown to enhance LIBS spectra. Several researches have reported significant increases in signal-to-noise and or spectral intensity [1-4]. In addition to DP-LIBS, atmospheric conditions can also increase spectra intensity. For example, Iida [5] found that He and Ar both increase LIBS intensity compared to air at one 1 atm. It was also found that as the pressure was decreased to 100 Torr, LIBS intensity increased in Ar and air for single pulse (SP) LIBS. In this study, a collinear DP-LIBS scheme is used along with manipulation of the atmospheric conditions. The DP-LIBS scheme consists of a 355 nm ablative pulse fired into a sample contained in a vacuum chamber. A second analytical 1064 nm pulse is then fired 100 ns to 10 µs after and along the same path of the first pulse. Ar, He and air at pressures ranging from atmospheric pressure (630 Torr at elevation) to 10-5 Torr are introduced during DP-LIBS and SP-LIBS experiments. For a brass sample, a significant increase in spectral intensity of Cu and Zn lines were observed in DP-LIBS under Ar compared to DP-LIBS in air (Figure 1). It was also found that Cu and Zn lines acquired with SP-LIBS in Ar are nearly as intense as DP-LIBS in air. Signal-to-noise for lines from various samples will be reported for both DP-LIBS and SP-LIBS in Ar, He, and air at pressures ranging from 630 Torr to 10-5 Torr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Construction and Design of a full size sTGC prototype for the ATLAS New Small Wheel upgrade

For the forthcoming Phase-I upgrade to the LHC (2018/19), the first station of the ATLAS muon end-cap system, Small Wheel, will need to be replaced. The New Small Wheel (NSW) will have to operate in a high background radiation region while reconstructing muon tracks with high precision as well as furnishing information for the Level-1 trigger. In particular, the precision reconstruction of tracks requires a spatial resolution of about 100 μm, and the Level-1 trigger track segments have to be reconstructed with an angular resolution of approximately 1 mrad. The NSW will have two chamber technologies, one primarily devoted to the Level-1 trigger function the small-strip Thin Gap Chambers (sTGC) and one dedicated to precision tracking, Micromegas detectors, (MM). The single sTGC planes of a quadruplet consists of an anode layer of 50 μm gold plated tungsten wire sandwiched between two resistive cathode layers. Behind one of the resistive cathode layers, a PCB with precise machined strips (thus the name sTGC's) spaced every 3.2 mm allows to achieve the position resolution that ranges from 70 to 150 μm, depending on the incident particle angle. Behind the second cathode, a PCB that contains an arrangement of pads, allows for a fast coincidence between successive sTGC layers to tag the passage of a track and reads only the corresponding strips for triggering. To be able to profit from the high accuracy of each of the sTGC planes for trigger purposes, their relative geometrical position between planes has to be controlled to within a precision of about 40 μm in their parallelism, as well (due to the various incident angles), to within a precision of 80 μm in the relative distance between the planes to achieve the overall angular resolution of 1 mrad. The needed accuracy in the position and parallelism of the strips is achieved by machining brass inserts together when machining the strip patterns into the cathode boards in a single step. The inserts can then be used as external references on a granite table. Precision methods are used to maintain high accuracy when combining four single detector gaps first into two doublets and then into a quadruplet. We will present results on the ongoing construction of full size (∼1 x 1 m) sTGC quadruplet prototypes before full construction starts in 2015. (authors)

43 PARTICLE ACCELERATORS↗

Treatment of contaminated non-iron metals for clearance - 15361

Iron based metals and concrete make up most of the structures in a nuclear power plants and most other nuclear installations. During the last few decades, a lot of effort has been put into the treatment of steel in order to allow recycling of the metal and to reduce the volume for final disposal. In addition to the iron based metals, there are also other metals in significant amounts that can be treated for recycling and waste minimisation. Aluminium, lead, titanium, brass and copper have all been treated by Studsvik in the metals treatment facility in Sweden over the years. Some of these metals like lead and aluminium causes certain concerns (for reasons not related to their radioactivity) if they were to be disposed as radioactive waste. Other as copper and titanium has a high economic value if recycled outside the nuclear industry. Studsvik experience from treatment of non-iron metals is reported in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decontamination of uranium contaminated metals - 15 years of experience - 15528

Uranium contaminated waste is somewhat of a special case among radioactive waste as the uranium, if enriched, also is a valuable asset. Incineration and pyrolysis of uranium contaminated dry active waste (DAW) was covered during WM'14. Uranium contaminated metals is however somewhat different when it comes treatment and recovery of uranium. Since the late 1990's the Metals Treatment and Recycling Facility in Studsvik Sweden has treated approximately 1500 tonnes of metals contaminated by uranium. Depending on the metal, melt-decontamination may or may not be a way of salvaging metals if the pre-treatment was not enough. The only metals that currently are subject to melt decontamination are iron based materials as well as lead. Other metals such as aluminium, brass and copper must all be cleaned prior to melting. Recovery of uranium from the secondary waste is most likely economically feasible only from the first step, the pre-melting decontamination, as the slag is just that, a slag, which is molten at a high temperature, and thereafter cooled under non-controlled conditions so uranium is trapped inside in an unspecified chemical form. This paper will describes experiences and lessons learned from 15 years of treatment, including melt-decontamination, of uranium contaminated metals. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Time-resolved studies of particle effects in laser ablation inductively coupled plasma-mass spectrometry

Time resolved signals in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are studied to determine the influence of experimental parameters on ICP-induced fractionation effects. Differences in sample composition and morphology, i.e., ablating brass, glass, or dust pellets, have a profound effect on the time resolved signal. Helium transport gas significantly decreases large positive signal spikes arising from large particles in the ICP. A binder for pellets also reduces the abundance and amplitude of spikes in the signal. MO{sup +} ions also yield signal spikes, but these MO{sup +} spikes generally occur at different times from their atomic ion counterparts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effects of Material-Filled Voids on Detonation Wave Shape in Rubberized RDX Explosives

The sensitivity of explosives is affected by inhomogeneities within the material. This is evident in the increased shock sensitivity of explosives with slightly lower densities resulting from an increased number of hotspots. The influence of hotspots on explosive initiation has been well studied; however, few studies have been conducted on the effect of intermediate-sized voids (0.1–10 mm) on a propagating detonation wave. Cylindrical voids filled with air have been studied for diameters ranging from 0.3 mm to 0.8 mm for both 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX) and 1,3,5-trinitro-1,3,5-triazinane (RDX)-based rubberized explosives. Continuing the investigation into single cylindrical voids, this study examined the effects of 0.5 mm diameter voids filled with different inert cylindrical metals on the detonation wave shape for an RDX-based rubberized explosive. The metals selected for experiments were 1066 aluminum, brass, copper, and tungsten. The propagation of the detonation wave was captured using a digital streak camera. Experimental results showed that the extent of detonation wave shaping was closely tied to the density differential between the bulk explosive and metal insert. Forty-four different filler materials, including non-metals, were simulated using a hydrodynamic code to further analyze material inclusion effects. The main factors hypothesized to be of interest were bulk sound speed, shock impedance, and filler material density. We found that the local detonation delay could be correlated fairly well to a ratio of bulk sound speed and density. Understanding the influence of material inclusions on detonation performance and wave shape allows for tailoring of detonations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Effects of Changing Hot Rolling Direction on Microstructure, Texture and Mechanical Properties of Cu-2.7Be Sheets

A hot rolling scheme (cross-rolling and unidirectional rolling) was adopted to process Cu-2.7Be sheets used as multiplier dynodes in photomultiplier. The effects of changing rolling direction on microstructure, texture and mechanical properties were studied by a combination of XRD, EBSD and TEM. It was found that higher copper-type texture and lower brass texture intensity were obtained in the ultimately cross-rolling (CR) sheet compared with the unidirectional rolling (UR) sheet.The EBSD results indicated that the grain orientation from mainly 〈101〉 for UR sample turns to random for CR sample. Great enhancements in YS and UTS after unidirectional rolling were attributed to the massive and polygonal γ precipitates. The CR sample exhibited lower anisotropy, because of the increase of S and γ precipitates with spherical and tiny shape.

36 MATERIALS SCIENCE↗

Acoustic Emission Responses of Three Typical Metals During Plastic and Creep Deformations

In this paper, the acoustic emission (AE) responses of three typical engineering metals (namely, Q235 carbon steel, H62 brass and 304 stainless steel) during plastic and high-temperature creep deformations were experimentally investigated. To gain insight into the AE response mechanisms, the micro scale mechanical behaviors of these metals were studied with a micro-tensile tester with observation by scanning electron microscopy (SEM). The following observations were found: (1) although the intensities and activities of the AE signals greatly differed under the same configurations, the AE peak values appeared at the transition from elasticity to plasticity for all three metals; (2) compared to the AE signal intensity during plastic deformation, the signal intensity during high-temperature creep was much weaker; (3) slip lines appeared within the crystal grains at the stress level corresponding to the peak AE signal intensity, but the densities of the slip lines and their crossover were not proportional to the AE signals of the metals. From these findings, the following conclusions were drawn about the application of AE: (1) AE is more scientific method to determine the yielding point of a metal without plastic flow than the nominal yield stress; (2) AE can be used to determine the deformation mechanism at high temperature, particularly, to distinguish creep from plastic deformation; (3) the AE response is the result of a sudden energy release by dislocation motion; however, the AE signal intensity is not necessarily proportional to the dislocation activity.

36 MATERIALS SCIENCE↗

A thermal active restrained shrinkage ring test to study the early age concrete behaviour of massive structures

In massive concrete structures, cracking may occur during hardening, especially if autogenous and thermal strains are restrained. The concrete permeability due to this cracking may rise significantly and thus increase leakage (in tank, nuclear containment...) and reduce the durability. The restrained shrinkage ring test is used to study the early age concrete behaviour (delayed strains evolution and cracking). This test shows, at 20 {sup o}C and without drying, for a concrete mix which is representative of a French nuclear power plant containment vessel (w/c ratio equal to 0.57), that the amplitude of autogenous shrinkage (about 40 {mu}m/m for the studied concrete mix) is not high enough to cause cracking. Indeed, in this configuration, thermal shrinkage is not significant, whereas this is a major concern for massive structures. Therefore, an active test has been developed to study cracking due to restrained thermal shrinkage. This test is an evolution of the classical restrained shrinkage ring test. It allows to take into account both autogenous and thermal shrinkages. Its principle is to create the thermal strain effects by increasing the temperature of the brass ring (by a fluid circulation) in order to expand it. With this test, the early age cracking due to restrained shrinkage, the influence of reinforcement and construction joints have been experimentally studied. It shows that, as expected, reinforcement leads to an increase of the number of cracks but a decrease of crack widths. Moreover, cracking occurs preferentially at the construction joint.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling and experimental study of nucleate boiling on a vertical array of horizontal plain tubes

An investigation of nucleate boiling on a vertical array of horizontal plain tubes is presented in this paper. Experiments were performed with refrigerant R123 at reduced pressures varying from 0.022 to 0.64, tube pitch to diameter ratios of 1.32, 1.53 and 2.00, and heat fluxes from 0.5 to 40 kW/m{sup 2}. Brass tubes with external diameters of 19.05 mm and average roughness of 0.12 {mu}m were used in the experiments. The effect of the tube spacing on the local heat transfer coefficient along the tube array was negligible within the present range of experimental conditions. For partial nucleate boiling, characterized by low heat fluxes, and low reduced pressures, the tube positioning shows a remarkable effect on the heat transfer coefficient. Based on these data, a general correlation for the prediction of the nucleate boiling heat transfer coefficient on a vertical array of horizontal tubes under flooded conditions was proposed. According to this correlation, the ratio between the heat transfer coefficients of a given tube and the lowest tube in the array depends only on the tube row number, the reduced pressure and the heat flux. By using the proposed correlation, most of the experimental heat transfer coefficients obtained in the present study were predicted within {+-}15%. The new correlation compares reasonably well with independent data from the literature. (author)

42 ENGINEERING↗

Secondary Neutron Doses for Several Beam Configurations for Proton Therapy

Purpose: To compare possible neutron doses produced in scanning and scattering modes, with the latter assessed using a newly built passive-scattering proton beam line. Methods and Materials: A 40 x 30.5 x 30-cm water phantom was irradiated with 230-MeV proton beams using a gantry angle of 270{sup o}, a 10-cm-diameter snout, and a brass aperture with a diameter of 7 cm and a thickness of 6.5 cm. The secondary neutron doses during irradiation were measured at various points using CR-39 detectors, and these measurements were cross-checked using a neutron survey meter with a 22-cm range and a 5-cm spread-out Bragg peak. Results: The maximum doses due to secondary neutrons produced by a scattering beam-delivery system were on the order of 0.152 mSv/Gy and 1.17 mSv/Gy at 50 cm from the beam isocenter in the longitudinal (0{sup o}) and perpendicular (90{sup o}) directions, respectively. The neutron dose equivalent to the proton absorbed dose, measured from 10 cm to 100 cm from the isocenter, ranged from 0.071 mSv/Gy to 1.96 mSv/Gy in the direction of the beam line (i.e., {phi} = 0 deg.). The largest neutron dose, of 3.88 mSv/Gy, was observed at 135{sup o} and 25 cm from the isocenter. Conclusions: Although the secondary neutron doses in proton therapy were higher when a scattering mode rather than a scanning mode was used, they did not exceed the scattered photon dose in typical photon treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrodeposition of preferentially oriented zinc for flow-assisted alkaline batteries

Preferred orientation of zinc deposits during charging is shown to significantly improve performance and cycle life in flow-assisted alkaline zinc batteries, which has not been demonstrated earlier. The preferred orientation of zinc deposits was investigated using X-ray diffraction (XRD). Compact zinc is found to have (11 (2) over bar2) preferred orientation on brass, which contributes to similar to 60% of the texture. The effect of charging current and zincate concentration on morphology was investigated in a rotating hull cell and correlated with anodic efficiency. Compact zinc deposits are found to have a fine-grained, bright finish and the highest anodic efficiency. Electrochemical impedance spectroscopy (EIS) proves that compact zinc corresponds to the minimum in the half-cell resistance. Morphological control using compact zinc could be accomplished using innovations such as pulse charging or enhanced mass-transfer to improve anode performance without affecting the cathode. (C) 2014 Elsevier B.V. All rights reserved.

Desai, D↗

Self-equilibrated backstresses induce compensation between hardening and softening: Micromechanical and microstructural features

For crystal plasticity formulation neglecting the strain gradients at the dislocation scale, backstresses are necessary to satisfy the mesoscopic stress equilibrium and strain compatibility requirements. Backstresses in a material point and those between neighboring points are treated separately. Physically backstresses can dynamically induce either hardening or softening effects to adjust the dislocation hardening of slip systems, whereas the sum of the stresses resulting in backstresses in the representative volume element (RVE) is zero. Backstress hardening suppresses certain slip activities, while backstress softening triggers excess dislocations. A two-phase brass is studied. Backstresses make the hard phase deform smaller and the soft phase deform more than those without employing backstresses in a model. In the former, more homogeneous lattice strain and higher yield stress are obtained. Backstress has limited effects on the evolution of the critical resolved shear stress and crystallographic texture. Furthermore, it is a major cause of the banded structures featuring sharp crystallographic contrasts which are not parallel to the slip planes. Tests indicate that backstress induces a serrated behavior at the early stages of deformation and induces the geometrically necessary bands (GNBs), which are parallel to the macroscopic axes.

36 MATERIALS SCIENCE↗

Determination of energy-dependent neutron backgrounds using shadow bars

Understanding the neutron background is essential for determining the neutron yield from nuclear reactions. Here, the neutron backgrounds were determined for heavy-ion collision experiment using the shadow-bar method, where beams of 40,48 Ca at 56, 140 MeV/u impinged on targets of 58,64 Ni and 112,124 Sn. In the analysis presented here, brass shadow bars are placed in front of organic liquid scintillator neutron detectors to determine the energy-dependent neutron background fractions. The measurement of neutron spectra with and without shadow bars is important to determine the neutron background more accurately. The neutron background, along with its sources and systematic uncertainties, are explored with a focus on the impact of background models and their dependence on neutron energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct measurement and calculation of rubber bulk modulus by piston-cylinder method using conventional mechanical testing equipment

This article describes a method to directly measure the bulk modulus of rubber using a piston-cylinder type apparatus. The function of the testing apparatus is to reliably transfer load to the water inside the vessel and allow for the accurate and continuous measurement of volumetric displacement as the contents are compressed. During the test, load is applied to a piston-cylinder containing the rubber test sample and water using a conventional mechanical testing load frame. Load and the travel of the piston are recorded by a load cell and extensometer, respectfully. A brass or stainless steel plug of the same dimensions as the test sample is tested as a control sample to isolate the compliance of the system, including the compressibility of water and compliance of the piston-cylinder. The results from this control test are used to disincorporate the compliance of the system from the sample test results. Load-linear displacement data are mathematically converted to pressure-volumetric displacement data, from which bulk modulus is calculated. The test apparatus and method are validated using the known bulk modulus of water. Finally, the bulk modulus for two similar rubbers is evaluated. The validity of the results and limitations of the device are discussed.

36 MATERIALS SCIENCE↗