Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SPLITTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

SU-E-T-361: Clinical Benefit of Automatic Beam Gating Mixed with Breath Hold in Radiation Therapy of Left Breast

Purpose: To investigate the clinical and dosimetric benefits of automatic gating of left breast mixed with breath-hold technique. Methods: Two Active Breathing Control systems, ABC2.0 and ABC3.0, were used during simulation and treatment delivery. The two systems are different such that ABC2.0 is a breath-hold system without beam control capability, while ABC3.0 has capability in both breath-hold and beam gating. At simulation, each patient was scanned twice: one with free breathing (FB) and one with breath hold through ABC. Treatment plan was generated on the CT with ABC. The same plan was also recalculated on the CT with FB. These two plans were compared to assess plan quality. For treatments with ABC2.0, beams with MU > 55 were manually split into multiple subfields. All subfields were identical and shared the total MU. For treatment with ABC3.0, beam splitting was unnecessary. Instead, treatment was delivered in gating mode mixed with breath-hold technique. Treatment delivery efficiency using the two systems was compared. Results: The prescribed dose was 50.4Gy at 1.8Gy/fraction. The maximum heart dose averaged over 10 patients was 46.0±2.5Gy and 24.5±12.2Gy for treatments with FB and with ABC respectively. The corresponding heart V10 was 13.2±3.6% and 1.0±1.6% respectively. The averaged MUs were 99.8±7.5 for LMT, 99.2±9.4 for LLT. For treatment with ABC2.0, normally the original beam was split into 2 subfields. The averaged total time to delivery all beams was 4.3±0.4min for treatments with ABC2.0 and 3.3±0.6min for treatments with ABC3.0 in gating mode. Conclusion: Treatment with ABC tremendously reduced heart dose. Compared to treatments with ABC2.0, gating with ABC3.0 reduced the total treatment time by 23%. Use of ABC3.0 improved the delivery efficiency, and eliminated the possibility of mistreatments. The latter may happen with ABC2.0 where beam is not terminated when breath signal falls outside of the treatment window.

60 APPLIED LIFE SCIENCES↗

Advanced-Ignition-Concept Exploration on OMEGA

Advanced ignition concepts, such as fast ignition and shock ignition, are being investigated at the Omega Laser Facility. Integrated fast-ignition experiments with room-temperature re-entrant cone targets have begun, using 18 kJ of 351 nm drive energy to implode empty 40μm thick CD shells, followed by 1.0 kJ of 1053 nm wavelength, short-pulse energy. Short pulses of 10 ps width have irradiated the inside of a hollow gold re-entrant cone at the time of peak compression. A threefold increase in the time-integrated, 2 to 7 keV x-ray emission was observed with x-ray pinhole cameras, indicating that energy is coupled from the short-pulse laser into the core by fast electrons. In shock-ignition experiments, spherical plastic-shell targets were compressed to high areal densities on a low adiabat, and a strong shock wave was sent into the converging, compressed capsule. In one experiment, 60 beams were used with an intensity spike at the end of the laser pulse, and the implosion performance was studied through neutron-yield and areal-density measurements. In a second experiment, the 60 OMEGA beams were split into a 40+20 configuration, with 40 low-intensity beams used for fuel assembly and 20 delayed beams with a short, high-intensity pulse shape (up to 1×1016 Wcm^-2) for shock generation.

Theobald, W↗

Advanced-Ignition-Concept Exploration on OMEGA

Advanced ignition concepts, such as fast ignition and shock ignition, are being investigated at the Omega Laser Facility. Integrated fast-ignition experiments with room-temperature re-entrant cone targets have begun, using 18 kJ of 351 nm drive energy to implode empty 40μm thick CD shells, followed by 1.0 kJ of 1053 nm wavelength, short-pulse energy. Short pulses of 10 ps width have irradiated the inside of a hollow gold re-entrant cone at the time of peak compression. A threefold increase in the time-integrated, 2 to 7 keV x-ray emission was observed with x-ray pinhole cameras, indicating that energy is coupled from the short-pulse laser into the core by fast electrons. In shock-ignition experiments, spherical plastic-shell targets were compressed to high areal densities on a low adiabat, and a strong shock wave was sent into the converging, compressed capsule. In one experiment, 60 beams were used with an intensity spike at the end of the laser pulse, and the implosion performance was studied through neutron-yield and areal-density measurements. In a second experiment, the 60 OMEGA beams were split into a 40+20 configuration, with 40 low-intensity beams used for fuel assembly and 20 delayed beams with a short, high-intensity pulse shape (up to 1×10 16 Wcm -2 ) for shock generation.

42 ENGINEERING↗

Achromatic registration of quadrature components of the optical spectrum in spectral domain optical coherence tomography

We have thoroughly investigated the method of simultaneous reception of spectral components with the achromatised quadrature phase shift between two portions of a reference wave, designed for the effective suppression of the 'mirror' artefact in the resulting image obtained by means of spectral domain optical coherence tomography (SD OCT). We have developed and experimentally tested a phase-shifting element consisting of a beam divider, which splits the reference optical beam into the two beams, and of delay lines being individual for each beam, which create a mutual phase difference of π/2 in the double pass of the reference beam. The phase shift achromatism over a wide spectral range is achieved by using in the delay lines the individual elements with different dispersion characteristics. The ranges of admissible adjustment parameters of the achromatised delay line are estimated for exact and inexact conformity of the geometric characteristics of its components to those calculated. A possibility of simultaneous recording of the close-to-quadrature spectral components with a single linear photodetector element is experimentally confirmed. The suppression of the artefact mirror peak in the OCT-signal by an additional 9 dB relative to the level of its suppression is experimentally achieved when the air delay line is used. Two-dimensional images of the surface positioned at an angle to the axis of the probe beam are obtained with the correction of the 'mirror' artefact while maintaining the dynamic range of the image. (laser biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation on the properties of a laminar grating as a soft x-ray beam splitter

Laminar-type gratings as soft x-ray beam splitters for interferometry are presented. Gold-coated grating beam splitters with 1000 lines/mm are designed for grazing incidence operation at 13.9nm. They are routinely fabricated using electron beam lithography and ion etching techniques. The laminar grating is measured to have almost equal absolute efficiencies of about 20% in the zeroth and -1st orders, which enables a fringe visibility up to 0.99 in the interferometer. The discrepancy of the grating profiles between the optimized theoretical and the experimental results is analyzed according to the comparison of the optimized simulation results and the measurement realization of the grating efficiencies. By a precise control of the grating profile, the grating efficiency in the -1st order and the fringe visibility could be improved to 25% and 1, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three dimensional imaging utilizing structured light

This paper describes a method of remote sensing 3-dimensional structure of the proximity utilizing a laser, a holographic grating, and a single regular CCD camera. Basically, the laser beam is split by a holographic grating to form a regular spaced grid of laser beams that are projected into the field of view of a CCD camera.

Chang, Johnny↗

WE-DE-207B-01: Optimization for Contrast-Enhanced Spectral Mammography Based On Photon-Counting Detectors

Purpose: To investigate the feasibility of optimizing the imaging parameters for contrast-enhanced spectral mammography based on Si strip photon-counting detectors. Methods: A computer simulation model using polyenergetic spectra from a tungsten anode x-ray tube and a Si-based photon-counting detector was evaluated for contrast-enhanced spectral mammography. The simulation traces the emission of photons from the x-ray source, attenuation through the breast and subsequent absorption in the detector. The breast was modeled as a mixture of adipose and mammary gland tissues with a breast density of 30%. A 4 mm iodine signal with a concentration of 4 mg/ml was used to simulate the enhancement of a lesion. Quantum efficiency of the detector was calculated based on the effective attenuation length in the Si strips. The figure-of-merit (FOM), which was defined as the decomposed iodine signal-to-noise ratio (SNR) with respect to the square root of the mean glandular dose (MGD), was chosen to optimize the imaging parameters, in terms of beam energy, splitting energy, and pre-filtrations for breast of various thicknesses and densities. Results: The optimal imaging parameters, which lead to the highest FOM, were found at a beam energy of 45 kVp with a splitting energy at 34 keV for an averaged breast thickness of 4 cm with a standard 0.75 mm Al pre-filtration. The optimal tube voltage varied slightly from 46 to 44 kVp as the breast thickness increases from 2 to 8 cm. The optimal tube voltage decreased to 42 kVp when the Al pre-filtration was increased to 3 mm. Conclusion: This simulation study predicted the optimal imaging parameters for application of photon-counting spectral mammography to contrast-enhanced imaging. The simulation results laid the ground work for future phantom and clinical studies. Grant funding from Philips Medical Systems.

60 APPLIED LIFE SCIENCES↗

Single-Ion Two-Photon Source

A single trapped ion is converted into a pseudo-two-photon source by splitting its resonance fluorescence, delaying part of it and by recombining both parts on a beam splitter. A destructive two-photon interference is observed with a contrast reaching 83(5)%. The spectral brightness of our two-photon source is quantified and shown to be comparable to parametric down-conversion devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparison of the analytical and simulation results of the equilibrium beam profile

The evolution of high current electron beams in dense plasmas has been investigated by using two-dimensional particle-in-cell (PIC) simulations with immobile ions. It is shown that electron beams are split into many filaments at the beginning due to the Weibel instability, and then different filamentation beams attract each other and coalesce. The profile of the filaments can be described by formulas. Hammer et al. [Phys. Fluids 13, 1831 (1970)] developed a self-consistent relativistic electron beam model that allows the propagation of relativistic electron fluxes in excess of the Alfven-Lawson critical-current limit for a fully neutralized beam. The equilibrium solution has been observed in the simulation results, but the electron distribution function assumed by Hammer et al. is different from the simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffraction-based optical correlator

Method and system for wavelength-based processing of a light beam. A light beam, produced at a chemical or physical reaction site and having at least first and second wavelengths, ?1 and ?2, is received and diffracted at a first diffraction grating to provide first and second diffracted beams, which are received and analyzed in terms of wavelength and/or time at two spaced apart light detectors. In a second embodiment, light from first and second sources is diffracted and compared in terms of wavelength and/or time to determine if the two beams arise from the same source. In a third embodiment, a light beam is split and diffracted and passed through first and second environments to study differential effects. In a fourth embodiment, diffracted light beam components, having first and second wavelengths, are received sequentially at a reaction site to determine whether a specified reaction is promoted, based on order of receipt of the beams. In a fifth embodiment, a cylindrically shaped diffraction grating (uniform or chirped) is rotated and translated to provide a sequence of diffracted beams with different wavelengths. In a sixth embodiment, incident light, representing one or more symbols, is successively diffracted from first and second diffraction gratings and is received at different light detectors, depending upon the wavelengths present in the incident light.

Spremo, Stevan M.↗

Multispectral scanner optical system

An optical system for use in a multispectral scanner of the type used in video imaging devices is disclosed. Electromagnetic radiation reflected by a rotating scan mirror is focused by a concave primary telescope mirror and collimated by a second concave mirror. The collimated beam is split by a dichroic filter which transmits radiant energy in the infrared spectrum and reflects visible and near infrared energy. The long wavelength beam is filtered and focused on an infrared detector positioned in a cryogenic environment. The short wavelength beam is dispersed by a pair of prisms, then projected on an array of detectors also mounted in a cryogenic environment and oriented at an angle relative to the optical path of the dispersed short wavelength beam.

Stokes, R. C.↗

Multiphoton- and simultaneous conjugate Ramsey-Borde atom interferometers

We report on our experiment to measure h/M, the ratio of the Planck constant to the mass of Cs atoms, and thereby the fine-structure constant. The target accuracy is 1 part per billion or better. We focus on two recent milestones: (i) The first realization of atom interferometers based on light-pulse beam splitters that transfer the momentum of up to 12 photon pairs, which increases the useful signal (matter wave phase shift) by a factor of 144 compared to the beam splitters used in the best present atom interferometers. Moreover, they lead to a cancellation of important systematic effects. (ii) The first realization of a simultaneous pair of conjugate Ramsey-Borde interferometers. In these, the relative sign of the inertial term is reversed so that it can be cancelled. Simultaneous operation means that this holds for a time-dependent inertial term (vibrations) too, which promises a substantial improvement in the signal to noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarimetry diagnostic on OMEGA EP using a 10-ps, 263-nm probe beam

A polarimetry diagnostic was built and characterized for magnetic-field measurements in laser-plasma experiments on the OMEGA EP laser. This diagnostic was built into the existing 4ω (263-nm) probe system that employs a 10-ps laser pulse collected with an f/4 imaging system. The diagnostic measures the rotation of the probe beam's polarization. The polarimeter uses a Wollaston prism to split the probe beam into orthogonal polarization components. Spatially localized intensity variations between images indicate polarization rotation. Magnetic fields can be calculated by combining the polarimetry data with the measured plasma density profile obtained from angular filter refractometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-domain squeezing and quantum distributions in the pulsed regime

We investigate time-dependent properties of Einstein-Podolsky-Rosen (EPR) light beams generated in a nondegenerate optical parametric oscillator (NOPO) driven by a sequence of laser pulses with Gaussian time-dependent envelopes. This investigation continues our previous analysis [H. H. Adamyan and G. Yu. Kryuchkyan, Phys. Rev. A 74, 023810 (2006)] and involves problems of two-mode quadrature squeezing as well as intensity-difference squeezing in the time domain. The peculiarities of EPR beams are also discussed in the framework of phase-space quantum distributions. Two kinds of non-Gaussian Wigner functions, for the reduced one-mode state of periodically pulsed NOPO and for EPR beams which are combined on a one-half beam splitter are calculated numerically. We also investigate the Wigner functions of intensity-correlated twin beams following the conditional photon state-preparation scheme. It is demonstrated that the Wigner functions involve negative values in parts of the phase space for the schemes with one, two, and three photons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mass Gauging Demonstrator for Any Gravitational Conditions

The present invention is a mass gauging interferometry system used to determine the volume contained within a tank. By using an optical interferometric technique to determine gas density and/or pressure a much smaller compression volume or higher fidelity measurement is possible. The mass gauging interferometer system is comprised of an optical source, a component that splits the optical source into a plurality of beams, a component that recombines the split beams, an optical cell operatively coupled to a tank, a detector for detecting fringes, and a means for compression. A portion of the beam travels through the optical cell operatively coupled to the tank, while the other beam(s) is a reference.

Korman, Valentin↗

Recent Beam Stability Analysis for the EIC

This document summarizes work done in WBS 6.02.02 during FY23. Additional details can be found in the EIC overview paper presented at IPAC’23 [1], and the references therein. Progress has been made in the ESR and HSR lattice design, dynamic aperture optimization, and the RCS lattice design. The impedance and Collective effects are progressing and include the impedance optimization process of the vacuum systems for RCS, HSR, and ESR; collective effects studies; collective effects and beam-beam interaction; coupled bunch instabilities and the crab cavities; low-level RF feedback system design and beam-ion instability. The reversed phasing RF system has been numerically studied for the ESR to mitigate Robinson instability and demonstrate reliable stable beam operation. Various codes, including C++, SPACE [2], ELEGANT [3], and Mbtrack2 [4] have been employed to benchmark the results. The simulation of HSR bunch splitting with beam loading has been performed at 275 GeV energy. The evaluation of Beam Position Monitors aimed to validate their expected performance, with the primary objective being to verify their accuracy. Calculations of Electron Polarization in the ESR, RCS, and HSR are showing good progress. In the RCS, preliminary studies indicate excellent polarization transmission over intrinsic spin resonances, achieving over 90% transmission with improved performance compared to the previous lattice. Preliminary simulations in the ESR indicate encouraging results in minimizing depolarization and improving equilibrium polarization.

43 PARTICLE ACCELERATORS↗

Local measurements of the pedestal magnetic field profile throughout the ELM cycle on DIII-D

We report new high speed localized measurements of the pedestal magnetic field during the edge localized mode (ELM) cycle of a DIII-D High confinement mode (H-mode) discharge indicate a temporally and spatial complex redistribution of the edge current density profile, $j_{edge}$. The measurement technique extracts the magnetic field magnitude, $\textit{B}$, via the spectral separation of Stark-split neutral beam radiation in the pedestal. Single spatial channel measurements from a novel spatial heterodyne spectrometer are validated in discharges with core current profile changes. The technique measures Stark-splitting changes that imply $\textit{B}$ changes as small as 1 mT with high time resolution (50 μs). At normalized poloidal flux $ψ_n$ = 1.0, $\textit{B}$ appears saturated in the inter-ELM period and then rapidly decreases in <200 μs by ~1%, before edge recycling emission begins to increase. Radially inboard of $j_{edge}$, $\textit{B}$ increases at the ELM crash. The behavior is consistent with a rapid collapse of $j_{edge}$ at the ELM crash and subsequent pedestal recovery. In some discharges, at $ψ_n$ < 0.96, changes in $\textit{B}$ are observed throughout the ELM cycle. In others, $\textit{B}$ recovers and is relatively stable until a few ms leading up to the next crash. Measurements of $\textit{B}$ during the H-mode transition show a large increase at $ψ_n$ = 1 with little change at $ψ_n$ = 0.9, consistent with the formation of the edge bootstrap current density peak. The $ψ_n$ = 0.9 spectrum is complicated by predicted changes to the Stark component intensities with density at the L–H transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗