A Comprehensive Study of Nanometer Resolution of the IPBPM at ATF2

High-resolution beam position monitors (IPBPMs) have been developed in order to measure the electron beam position at the focus point of ATF2 to a few nanometers in the vertical plane. To date, the IPBPM system has operated in test mode with a highest demonstrated resolution of 8.7 nm in the ATF extraction line during 2008. After expected noise source calculations there still remains 7.9 nm of noise of unexplained origin. We summarize the experimental work on the IPBPM system since this measurement and outline the possible origins of these sources. We then present a study plan to be performed at the ATF2 facility designed to identify and to improve the resolution performance and comment on the expected ultimate resolution of this system. The Accelerator Test Facility 2 (ATF2) is a test beamline for ILC final focus system in the framework of the ATF international collaboration which was constructed to extend the extraction line at ATF, located at KEK, Japan. There are two goals of the ATF2: firstly to demonstrate focusing to 37 nm vertical beam size, secondly to achieve a few nanometer level beam orbit stability at the focus point in the vertical plane. High-resolution beam position monitors (IPBPMs) for the interaction point (IP) have been developed in order to measure the electron beam position at the focus point of the ATF2 to a few nanometers in the vertical plane. The previous measured position resolution of IPBPMs was 8.7 nm for a 0.68 x 10{sup 10} e/bunch beam with a dynamic range of 5 {mu}m. The intrinsic noise of the system was estimated to be 2.6 nm at 10{sup 10} e/bunch. It is scaled to 3.8 nm at 0.68 x 10{sup 10} e/bunch which means that 7.9 nm of unknown noise remains. The origin of the unknown noise must be studied in order to improve the resolution. This paper describes the ongoing work to improve the resolution of IPBPMs.

43 PARTICLE ACCELERATORS↗

Steering an intense relativistic electron beam in a linear induction accelerator

The best electron beam transport through a linear induction accelerator (LIA) is achieved when the beam is well centered on the magnetic axis of the focusing solenoids. Since the beam may be injected offset from, or at an angle to, the centerline, dipole magnets are usually provided as a means to steer the beam and center it. Steering may be accomplished by trial and error, but this is very time consuming, especially for accelerators with a low repetition rate for beam position measurements and dipole adjustments. With this in mind, this article presents a steering method requiring a minimal number of measurements and adjustments to position the beam at any desired location, including positioning on the centerline.

47 OTHER INSTRUMENTATION↗

Beam Profile Measurement in MTA Beam Line for High Pressure RF Cavity Beam Test

Recent High Pressure RF (HPRF) cavity experiment at MuCool Test Area (MTA) has used 400 MeV Linac proton beam to study the beam loading effect. When the energetic proton beam passes through the cavity, it ionizes the inside gas and produces the electrons. These electrons consume RF power inside the cavity. Number of electrons produced per cm inside the cavity (at 950 psi Hydrogen gas) per incident proton is {approx} 1200. The measurement of beam position and profile are necessary. MTA is flammable gas (Hydrogen) hazard zone so we have developed a passive beam diagnostic instrument using Chromox-6 scintillation screen and CCD camera. This paper presents quantitative information about beam position and beam profile. Neutral density filter was used to avoid saturation of CCD camera. Image data is filtered and fitted with Gaussian function to compute the beam size. The beam profile obtained from scintillation screen shall be compared with multi-wire beam profile.

08 HYDROGEN↗

Optical diffraction radiation from a beam off a circular target

The use of optical diffraction radiation (ODR) as a diagnostic tool has increased in recent years. The potential of this technique has been demonstrated in several experiments at KEK [1], APS [2], FLASH [3] and possibly other facilities. These experiments were performed in extraction beam lines of lepton machines. However this technique can also be applied to high energy hadron beams. In this report we consider the ODR produced by such beams with the target as a round hole and apply the results to the Tevatron. This radiation is produced when a beam passes in the vicinity of a conducting target. The electro-magnetic fields due to the beam induce currents on the target and as the beam propagates, the currents change in time producing radiation both in the direction of beam propagation and along the direction of specular reflection from the target. This latter radiation, also termed backward diffraction radiation (BDR), is more useful for diagnostics since it can be directed out at the same longitudinal location as the target. This radiation is different from optical transition radiation (OTR) in which the beam passes through a metal target. Transition radiation is not suitable for continuous monitoring of a beam in a collider due to the beam energy loss and emittance growth and the fact that the target may be damaged. However the techniques for analyzing ODR are similar in many respects to those for OTR. Measurements of the radiation intensity either in the near field or far-field have been used to determine beam positions and sizes. For example, the beam size and beam position of a 1.28 GeV electron beam were measured in an extraction beam line at KEK [1] using the far-field angular distribution of the radiation. The near-field image was used to monitor the relative beam size of a 7 GeV electron beam in the extraction line at APS [2]. In principle, measurements of the beam divergence are also possible using the interference of ODR between two targets, as has been done with OTR. This paper is motivated by the desire to use this technique in colliders, especially for the LHC and possibly for future colliders envisaged such as the muon collider. A brief report on these prospects was presented earlier [4]. If the technique yields beam measurements with sufficient accuracy and reliability then the non-invasive nature would allow continuous monitoring during the length of a luminosity run. This would be valuable if the beam can be imaged close to the interaction points. Synchrotron radiation is already used as a non-invasive diagnostic tool in the Tevatron and will also be used in the LHC. The principal advantage of ODR is that it can be generated in a straight section and therefore used for imaging in an experimental insertion. The disadvantage is that the ODR flux is less copious than synchrotron radiation (OSR) and imaging will take longer than with OSR. In Section 2 we briefly discuss the parameters of different hadron colliders. In Section 3 we derive the basic results for the angular differential spectrum of ODR from a round hole due to a bunch. We apply these results in Section 4 to find the sensitivity of the spectrum to beam size and offset changes. In Section 5, we calculate the expected photon yield from a bunch per turn as a function of frequency and we use this to find the frequency range where a sufficiently strong ODR signal can be obtained. In Section 6 we do a brief comparison of the ODR spectrum with the OTR spectrum. We briefly list in Section 7 the experimental issues associated with measuring ODR when two beams are present. We end with our conclusions in Section 8. We will use CGS units throughout.

43 PARTICLE ACCELERATORS↗

Re-Evaluation of Active Interlock Envelopes Considering Insertion Device Correction Coils

The Active Interlock (AI) is a system that ensures that the beam position and angle through the NSLS-II storage ring is located so that the machine apertures that may be struck by synchrotron radiation are not exposed to high power beam which may compromise them. Of particular importance in the NSLS-II is to maintain the beam position and angle within the insertion device (ID) straights where insertions devices make high power x-ray beams for users which may compromise the storage ring vacuum chamber. The beam position and angle in the center of the insertion device is calculated using a pair of beam position monitors (BPMs) on either side of the device. The safe area of positions and angles within the insertion device is called the AI envelope. If there is a magnetic element between the BPMs, it needs to be accounted for in the calculation of the beam position and angle. In addition to the permanent magnet arrays that comprise the insertion device itself, there are correction coils that are used to correct any orbit distortions that are generated by imperfections in the device. It has recently come to our attention that these coils are not considered in the AI calculations, nor are the currents in these coils read by the AI. As it may be possible in theory for these coils to produce angles large enough that the synchrotron radiation beam may damage components, we analyzed the possibility for all ID types and configurations. In this report we show what changes are necessary for the AI envelope, and limits placed upon the correction coils to maintain operation of the storage ring without compromising protection.

36 MATERIALS SCIENCE↗

Measurement and Control of Beam Energy at the Fermilab 400 MeV Transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped of the extra electrons to become protons. Tuning Linac is performed using diagnostics to ensure stable intensity and energy while minimizing uncontrolled particle loss. I have been revisiting diagnostics in the Linac in order to understand their signals and to ensure their data is reliable. I revisited Beam Loss Monitors (BLMs) for the loss data confidence. For the confidence of energy data there were two approaches. The first approach was time-of-flight measurements using Beam Position Monitors (BPMs) and beam velocity stripline pick-up that provides beam phase data. The second approach used the relation between beam position data from BPMs and dispersion values from MAD-X simulation to calculate energy. Our goal after understanding the data from the Linac diagnostics and finding the data reliable is to control the L inac parameters using Machine Learning techniques to increase the reliability and quality of beam delivered from Linac.

43 PARTICLE ACCELERATORS↗

More than 10 years experience of beam monitoring with the Gantry 1 spot scanning proton therapy facility at PSI

Purpose: The beam monitoring equipments developed for the first PSI spot scanning proton therapy facility, Gantry 1, have been successfully used for more than 10 years. The purpose of this article is to summarize the author's experience in the beam monitoring technique for dynamic proton scanning. Methods: The spot dose delivery and verification use two independent beam monitoring and computer systems. In this article, the detector construction, electronic system, dosimetry, and quality assurance results are described in detail. The beam flux monitor is calibrated with a Faraday cup. The beam position monitoring is realized by measuring the magnetic fields of deflection magnets with Hall probes before applying the spot and by checking the beam position and width with an ionization strip chamber after the spot delivery. Results: The results of thimble ionization chamber dosimetry measurements are reproducible (with a mean deviation of less than 1% and a standard deviation of 1%). The resolution in the beam position measurement is of the order of a tenth of a millimeter. The tolerance of the beam position delivery and monitoring during scanning is less than 1.5 mm. Conclusions: The experiences gained with the successful operation of Gantry 1 represent a unique and solid background for the development of a new system, Gantry 2, in order to perform new advanced scanning techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Independent component analysis for beam measurements

Independent component analysis (ICA) has been used for data mining in many branches of science. In beam physics, ICA can be applied to analyze turn-by-turn beam position monitor data of beam motion. The narrow-band filtering of ICA provides us methods to identify and extract information on the linear betatron and synchrotron motion, effects of wake fields, etc. We show that the ICA is also a powerful tool to measure nonlinear magnetic field in accelerators. Numerical simulations are used to demonstrate the ability to obtain sextupole strengths at high precision. The methods can be extended to other higher order multipoles.

43 PARTICLE ACCELERATORS↗

Operational Performance of LCLS Beam Instrumentation

The Linac Coherent Light Source (LCLS) X-ray FEL utilizing the last km of the SLAC linac has been operational since April 2009 and finished its first successful user run last December. The various diagnostics for electron beam properties including beam position monitors, wire scanners, beam profile monitors, and bunch length diagnostics are presented as well as diagnostics for the X-ray beam. The low emittance and ultra-short electron beam required for X-ray FEL operation has implications on the transverse and longitudinal diagnostics. The coherence effects of the beam profile monitors and the challenges of measuring fs long bunches are discussed.

43 PARTICLE ACCELERATORS↗

Small Aperture BPM to Quadrupole Assembly Tolerance Study

The LCLS injector and linac systems utilize a series of quadrupole magnets with a beam position monitor (BPM) captured in the magnet pole tips. The BPM measures the electron beam position by comparing the electrical signal from 4 electrodes and interpolating beam position from these signals. The manufacturing tolerances of the magnet and BPM are critical in determining the mechanical precision of the electrodes relative to the nominal electron beam Z-axis. This study evaluates the statistical uncertainty of the electrodes center axis relative to the nominal electron beam axis.

43 PARTICLE ACCELERATORS↗

Quantitative Electron Beam‐Single Atom Interactions Enabled by Sub‐20‐pm Precision Targeting

The ability to probe and control matter at the picometer scale is essential for advancing quantum and energy technologies. Scanning transmission electron microscopy offers powerful capabilities for materials analysis and modification, but sample damage, drift, and scan distortions hinder single atom analysis and deterministic manipulation. Materials analysis and modification via electron–solid interactions can be transformed by precise delivery of electrons to a specified atomic location, maintaining the beam position despite drift, and minimizing collateral dose. Here a fast, low-dose, sub-20-pm precision electron beam positioning technique is developed, “atomic lock-on,” (ALO), which offers the ability to position the beam on a specific atomic column without previously irradiating that column. This technique is used to lock onto a single selected atomic location to repeatedly measure its weak electron energy loss signal despite sample drift. Moreover, electron beam-matter interactions in single atomic events are measured with μ s time resolution. This enables observation of single-atom dynamics, such as atomic bistability, revealing partially bonded atomic configurations and recapture phenomena. This opens prospects for using electron microscopy for high-precision measurements and deterministic control of matter for quantum technologies.

2D materials↗

SU-G-TeP4-12: Individual Beam QA for a Robotic Radiosurgery System Using a Scintillator Cone

Purpose: The targeting accuracy of the Cyberknife system is measured by end-to-end tests delivering multiple isocentric beams to a point in space. While the targeting accuracy of two representative beams can be determined by a Winston-Lutz-type test, no test is available today to determine the targeting accuracy of each clinical beam. We used a scintillator cone to measure the accuracy of each individual beam. Methods: The XRV-124 from Logos Systems Int’l is a scintillator cone with an imaging system that is able to measure individual beam vectors and a resulting error between planned and measured beam coordinates. We measured the targeting accuracy of isocentric and non-isocentric beams for a number of test cases using the Iris and the fixed collimator. The average difference between plan and measured beam position was 0.8–1.2mm across the collimator sizes and plans considered here. The max error for a single beam was 2.5mm for the isocentric plans, and 1.67mm for the non-isocentric plans. The standard deviation of the differences was 0.5mm or less. Conclusion: The CyberKnife System is specified to have an overall targeting accuracy for static targets of less than 0.95mm. In E2E tests using the XRV124 system we measure average beam accuracy between 0.8 to 1.23mm, with maximum of 2.5mm. We plan to investigate correlations between beam position error and robot position, and to quantify the effect of beam position errors on patient specific plans. Martina Descovich has received research support and speaker honoraria from Accuray.

60 APPLIED LIFE SCIENCES↗

Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head

Purpose: The Vero4DRT system has the capability for dynamic tumor-tracking (DTT) stereotactic irradiation using a unique gimbaled x-ray head. The purposes of this study were to develop DTT conformal arc irradiation and to estimate its geometric and dosimetric accuracy. Methods: The gimbaled x-ray head, supported on an O-ring gantry, was moved in the pan and tilt directions during O-ring gantry rotation. To evaluate the mechanical accuracy, the gimbaled x-ray head was moved during the gantry rotating according to input command signals without a target tracking, and a machine log analysis was performed. The difference between a command and a measured position was calculated as mechanical error. To evaluate beam-positioning accuracy, a moving phantom, which had a steel ball fixed at the center, was driven based on a sinusoidal wave (amplitude [A]: 20 mm, time period [T]: 4 s), a patient breathing motion with a regular pattern (A: 16 mm, average T: 4.5 s), and an irregular pattern (A: 7.2–23.0 mm, T: 2.3–10.0 s), and irradiated with DTT during gantry rotation. The beam-positioning error was evaluated as the difference between the centroid position of the irradiated field and the steel ball on images from an electronic portal imaging device. For dosimetric accuracy, dose distributions in static and moving targets were evaluated with DTT conformal arc irradiation. Results: The root mean squares (RMSs) of the mechanical error were up to 0.11 mm for pan motion and up to 0.14 mm for tilt motion. The RMSs of the beam-positioning error were within 0.23 mm for each pattern. The dose distribution in a moving phantom with tracking arc irradiation was in good agreement with that in static conditions. Conclusions: The gimbal positional accuracy was not degraded by gantry motion. As in the case of a fixed port, the Vero4DRT system showed adequate accuracy of DTT conformal arc irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of RF BPM Receivers for NSLS-II Project

The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.

43 PARTICLE ACCELERATORS↗

A Polarized High-Energy Photon Beam for Production of Exotic Mesons

This work describes design, prototyping and testing of various components of the Jefferson Lab Hall D photon beamline. These include coherent bremsstrahlung radiators to be used in this facility for generating the photon beam, a fine resolution hodoscope for the facility's tagging spectrometer, and a photon beam position sensor for stabilizing the beam on a collimator. The principal instrumentation project was the hodoscope: its design, implementation and beam testing will be thoroughly described. Studies of the coherent bremsstrahlung radiators involved X-ray characterization of diamond crystals to identify the appropriate line of manufactured radiators and the proper techniques for thinning them to the desired specification of the beamline. The photon beam position sensor project involved completion of a designed detector and its beam test. The results of these shorter studies will also be presented. The second part of this work discusses a Monte Carlo study of a possible photo-production and decay channel in the GlueX experiment that will be housed in the Hall D facility. Specifically, the γ p → Xp → b 1 π → ω π +1 π -1 channel was studied including its Amplitude Analysis. This exercise attempted to generate a possible physics signal, complete with internal angular momentum states, and be able to reconstruct the signal in the detector and find the proper set of JPC quantum numbers through an amplitude fit. Derivation of the proper set of amplitudes in the helicity basis is described, followed by a discussion of the implementation, generation of the data sets, reconstruction techniques, the amplitude fit and results of this study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pixelated transmission-mode diamond X-ray detector

Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60–100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ~1 kHz, which leads to an image sampling rate of ~30 Hz. This novel signal readout scheme was tested at beamline X28C at the National Synchrotron Light Source (white beam, 5–15 keV) and at beamline G3 at the Cornell High Energy Synchrotron Source (monochromatic beam, 11.3 keV) with incident beam flux ranges from 1.8 × 10 -2 to 90 W mm -2 . Test results show that the novel detector provides precise beam position (positional noise within 1%) and morphology information (error within 2%), with an additional software-controlled single channel mode providing accurate flux measurement (fluctuation within 1%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗