Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

An experiment on the threshold effect in the coherent wave instability

Results are reported from an experimental study of the threshold effect in the coherent wave instability in which a combination of simulated VLF noise 200 Hz wide, superimposed on a variable amplitude constant frequency test signal (about 3 kHz) is transmitted from Siple Station, Antarctica, and received at Lake Mistissini, Quebec. As the test signal is slowly ramped up in power a 'threshold' level at which growth and triggering of emissions begin (coherent wave instability) is reached. It is shown that sufficiently strong simulated noise supresses the coherent wave instability, which corresponds to increasing the threshold level. This experiment is repeated at progressively lower levels of the simulated noise, until the threshold level for growth and triggering on the test signal no longer changes. At this point the simulated noise power is estimated to equal typical background noise levels due to magnetospheric hiss in the interaction region. It is suggested that unducted magnetospheric hiss is responsible for the threshold effect.

Mielke, T. A.↗

Noise Considerations in the Design and Operation of V/STOL Aircraft

Available propulsion-system noise data have been applied to the problems of design and operation of V/STOL aircraft. In particular, considerations have been given to minimizing adverse community reaction for operations between airports and to minimizing detection due to noise for special missions. For minimizing adverse community reaction, configurations incorporating low-blade-loading rotors, low-tip-speed propellers, or turbofan-type engines are judged to be most satisfactory. For minimizing detection, consideration must be given to minimizing the noise of the generating airplane, having maximum background noise in the vicinity of the observer, and operating the aircraft at minimum altitude.

Maglieri, Domenic J.↗

High-Energy Electromagnetic Offline Follow-Up of Ligo-Virgo Gravitational-Wave Binary Coalescence Candidate Events

We present two different search methods for electromagnetic counterparts to gravitational-wave (GW) events from ground-based detectors using archival NASA high-energy data from the Fermi Gamma-ray Burst Monitor (GBM) and RXTE All-sky Monitor (ASM) instruments. To demonstrate the methods, we use a limited number of representative GW background noise events produced by a search for binary neutron star coalescence over the last two months of the LIGO-Virgo S6/VSR3 joint science run. Time and sky location provided by the GW data trigger a targeted search in the high-energy photon data. We use two custom pipelines: one to search for prompt gamma-ray counterparts in GBM, and the other to search for a variety of X-ray afterglow model signals in ASM. We measure the efficiency of the joint pipelines to weak gamma-ray burst counterparts, and a family of model X-ray afterglows. By requiring a detectable signal in either electromagnetic instrument coincident with a GW event, we are able to reject a large majority of GW candidates. This reduces the signal-to-noise ratio of the loudest surviving GW background event by around 15-20 percent.

gamma-ray burst: general↗

SU-F-T-638: Is There A Need For Immobilization in SRS?

Purpose: Frameless Stereotactic radiosurgery (SRS) is increasingly used in the clinic. Cone-Beam CT (CBCT) to simulation-CT match has replaced the 3-dimensional coordinate based set up using a stereotactic localizing frame. The SRS frame however served as both a localizing and immobilizing device. We seek to measure the quality of frameless (mask based) and frame based immobilization and evaluate its impact on target dose. Methods: Each SRS patient was set up by kV on-board imaging (OBI) and then fine-tuned with CBCT. A second CBCT was done at treatment-end to ascertain intrafraction motion. We compared pre- vs post-treatment CBCT shifts for both frameless and frame based SRS patients. CBCT to sim-CT fusion was repeated for each patient off-line to assess systematic residual image registration error. Each patient was re-planned with measured shifts to assess effects on target dose. Results: We analyzed 11 patients (12 lesions) treated with frameless SRS and 6 patients (11 lesions) with a fixed frame system. Average intra-fraction iso-center positioning errors for frameless and frame-based treatments were 1.24 ± 0.57 mm and 0.28 ± 0.08 mm (mean ± s.d.) respectively. Residual error in CBCT registration was 0.24 mm. The frameless positioning uncertainties led to target dose errors in Dmin and D95 of 15.5 ± 18.4% and 6.6 ± 9.1% respectively. The corresponding errors in fixed frame SRS were much lower with Dmin and D95 reduced by 4.2 ± 6.5% and D95 2.5 ± 3.8% respectively. Conclusion: Frameless mask provides good immobilization with average patient motion of 1.2 mm during treatment. This exceeds MRI voxel dimensions (∼0.43mm) used for target delineation. Frame-based SRS provides superior patient immobilization with measureable movement no greater than the background noise of the CBCT registration. Small lesions requiring submm precision are better served with a frame based SRS.

60 APPLIED LIFE SCIENCES↗

Effects of signal analysis parameters and noise removal on measured aircraft spectra

Special techniques must be applied when analyzing acoustic noise data from nonstationary sources such as aircraft flyover measurements. Since the Fourier transform is time dependent, the noise signal is divided into short time segments by introducing a window function so that the spectral characteristics remain reasonably stationary. Reducing the window width reduces the frequency resolution while increasing the window duration can lead to spectral smearing. A trade-off must be made between time resolution and frequency resolution. The effects of varying the window duration on narrow-band acoustic spectra and thus the frequency bin width are addressed in this study. The influence of window functions (rectangular, Hamming, etc.) are also investigated. Both a tonal noise source, XV-15 aircraft in the airplane mode, and a broadband noise source, a F-18 aircraft, are considered. When dealing with flight test data, not only is the signal nonstationary, often it is contaminated by both ambient background noise and internal noise generated by the data acquisition system and power generators. Since generator noise is highly tonal, this can be particularly troublesome when computing tone-corrected perceived noise level (PNLT). A scheme is presented in this paper to eliminate unwanted background and internal noise.

Kelly, Jeffrey J.↗

Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging

Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI{sub vol} = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in {sup 99m}Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI{sub vol} = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ{sub 140} {sub keV} on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed {sup 99m}Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect SPECT quantification is low (CTDI{sub vol} ∼ 4 μGy), the low dose limit for the CT exam as part of SPECT/CT will be guided by CT image quality requirements for anatomical localization and artifact reduction. A CT technique with higher kVp in combination with lower mAs is recommended when low-dose CT images are used for AC to minimize beam-hardening artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized principal component analysis on coronagraphic images of the fomalhaut system

We present the results of a study to optimize the principal component analysis (PCA) algorithm for planet detection, a new algorithm complementing angular differential imaging and locally optimized combination of images (LOCI) for increasing the contrast achievable next to a bright star. The stellar point spread function (PSF) is constructed by removing linear combinations of principal components, allowing the flux from an extrasolar planet to shine through. The number of principal components used determines how well the stellar PSF is globally modeled. Using more principal components may decrease the number of speckles in the final image, but also increases the background noise. We apply PCA to Fomalhaut Very Large Telescope NaCo images acquired at 4.05 μm with an apodized phase plate. We do not detect any companions, with a model dependent upper mass limit of 13-18 M {sub Jup} from 4-10 AU. PCA achieves greater sensitivity than the LOCI algorithm for the Fomalhaut coronagraphic data by up to 1 mag. We make several adaptations to the PCA code and determine which of these prove the most effective at maximizing the signal-to-noise from a planet very close to its parent star. We demonstrate that optimizing the number of principal components used in PCA proves most effective for pulling out a planet signal.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray microtomographic scanners

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wire Scanner Beam Profile Measurements: LANSCE Facility Beam Development

The Los Alamos Neutron Science Center (LANSCE) is replacing Wire Scanner (WS) beam profile measurement systems. Three beam development tests have taken place to test the new wire scanners under beam conditions. These beam development tests have integrated the WS actuator, cable plant, electronics processors and associated software and have used H{sup -} beams of different beam energy and current conditions. In addition, the WS measurement-system beam tests verified actuator control systems for minimum profile bin repeatability and speed, checked for actuator backlash and positional stability, tested the replacement of simple broadband potentiometers with narrow band resolvers, and tested resolver use with National Instruments Compact Reconfigurable Input and Output (cRIO) Virtual Instrumentation. These beam tests also have verified how trans-impedance amplifiers react with various types of beam line background noise and how noise currents were not generated. This paper will describe these beam development tests and show some resulting data.

43 PARTICLE ACCELERATORS↗

Terahertz quantum-well photodetectors: Design, performance, and improvements

Theoretical studies and numerical simulations on design, performance, and improvements of terahertz quantum-well photodetector (THz QWP) are presented. In the first part of this paper, we discuss the device band structure resulting from a self-consistent solution and simulation results. First, the temperature dependence of device characteristics is analyzed. Next, we deduce the condition of optimal doping concentration for maximizing dark current limited detectivity D{sub det}* when QWP is lightly doped. Accordingly, unlike in previously published reports, doping concentration is not fixed and is selected by the above condition. In the second part of this paper, we propose two schemes for improving operation temperature. The first is to incorporate an optical antenna which focuses incident THz wave. Numerical results show that the QWP with peak frequency higher than 5.5 THz is expected to achieve background-noise-limited performance at 77 K or above when employing a 10{sup 6} times enhancement antenna. The second scheme is to use a laser as the signal source to achieve photon-noise-limited performance (PLIP) at high temperatures. Simulations show that when operating below critical temperature QWPs in the range of 1 ∼ 7 THz can reach PLIP under practical illumination intensities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of smart 3D-digital X-ray microtomographic scanners for non-destructive testing of materials and components of electronic devices with a multilayered structure

The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. Chapter 4 covers general procedures of defect search, which is based on vector analysis principles. In conclusion, the main applications of X-ray tomography are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radio counterparts of compact binary mergers detectable in gravitational waves: a simulation for an optimized survey

Mergers of binary neutron stars and black hole–neutron star binaries produce gravitational-wave (GW) emission and outflows with significant kinetic energies. These outflows result in radio emissions through synchrotron radiation. We explore the detectability of these synchrotron-generated radio signals by follow-up observations of GW merger events lacking a detection of electromagnetic counterparts in other wavelengths. We model radio light curves arising from (i) sub-relativistic merger ejecta and (ii) ultra-relativistic jets. The former produce radio remnants on timescales of a few years and the latter produce γ-ray bursts in the direction of the jet and orphan-radio afterglows extending over wider angles on timescales of weeks. Based on the derived light curves, we suggest an optimized survey at 1.4 GHz with five epochs separated by a logarithmic time interval. We estimate the detectability of the radio counterparts of simulated GW-merger events to be detected by advanced LIGO and Virgo by current and future radio facilities. The detectable distances for these GW merger events could be as high as 1 Gpc. Around 20%–60% of the long-lasting radio remnants will be detectable in the case of the moderate kinetic energy of 3⋅10{sup 50} erg and a circum-merger density of 0.1 cm{sup −3} or larger, while 5%–20% of the orphan-radio afterglows with kinetic energy of 10{sup 48} erg will be detectable. The detection likelihood increases if one focuses on the well-localizable GW events. We discuss the background noise due to radio fluxes of host galaxies and false positives arising from extragalactic radio transients and variable active galactic nuclei, and we show that the quiet radio transient sky is of great advantage when searching for the radio counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonclassical correlation of cascaded photon pairs emitted from quantum dots

We studied the quantum correlation of the photon pairs generated by biexciton cascade decays of self-assembled quantum dots, and determined the correlation sudden-change temperature, which is shown to be independent of the background noise, far lower than the entanglement sudden-death temperature, and therefore, easier to be observed in experiments. The relationship between the fine-structure splitting and the sudden-change temperature is also provided.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of collective Thomson scattering system using 77 GHz gyrotron for bulk and tail ion diagnostics in the large helical device

Collective Thomson scattering (CTS) system is expected to be a strong diagnostic tool for measuring thermal and fast ion distribution function at a local point inside plasmas. The electron cyclotron resonance heating system using a gyrotron at the frequency range of 77 GHz has been installed at the large helical device (LHD). The feasibility of CTS system using the 77 GHz gyrotron is assessed in terms of scattering spectrum and a background noise of the electron cyclotron emission, which affect the signal to noise ratio, with the realistic plasma parameters and incident port locations of LHD. Based on the calculated scattering spectra for bulk and tail fast ion diagnostics, the scattering radiation receiver system with gyrotron frequency feedback circuit is proposed to avoid the frequency chirping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed. This work was supported in part by NIH R01 CA0096679.

60 APPLIED LIFE SCIENCES↗

A Segmentation Algorithm for X-ray 3D Angiography and Vessel Catheterization

Vessel Catheterization is a clinical procedure usually performed by a specialist by means of X-ray fluoroscopic guide with contrast-media. In the present paper, we present a simple and efficient algorithm for vessel segmentation which allows vessel separation and extraction from the background (noise and signal coming from other organs). This would reduce the number of projections (X-ray scans) to reconstruct a complete and accurate 3D vascular model and the radiological risk, in particular for the patient. In what follows, the algorithm is described and some preliminary experimental results are reported illustrating the behaviour of the proposed method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frequency-selective plasmonic wave propagation through the overmoded waveguide with photonic-band-gap slab arrays

Confined propagation of guided waves through the periodically corrugated channel sandwiched between two staggered dielectric photonic-band-gap slab arrays is investigated with the band-response analysis. Numerical simulations show that longitudinally polarized evanescent waves within the band gap propagate with insertion loss of {approx}-0.2 to 1 dB (-0.05 to 0.4 dB/mm at G-band) in the hybrid band filter. This structure significantly suppresses low energy modes and higher-order-modes beyond the band-gap, including background noises, down to {approx}-45 dB. This would enable the single-mode propagation in the heavily over-moded waveguide (TEM-type), minimizing abnormal excitation probability of trapped modes. This band filter could be integrated with active and passive RF components for electron beam and optoelectronic devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental setup for laser spectroscopy of molecules in a high magnetic field

An experimental setup to measure the effects of a high magnetic field on the structure and decay dynamics of molecules is designed and constructed. A vacuum chamber is mounted in the bore of a superconducting magnet. A molecular beam passes in the chamber. Pulsed laser light excites the molecules in the field. The parent or fragment ions are extracted by an electric field parallel to the magnetic field. They are detected by a microchannel plate. Their mass and charge are determined by the time-of-flight method. The performance of the setup was examined using resonance-enhanced two-photon ionization through the X{sup 2} {Pi}-A{sup 2}{Sigma}{sup +} transition of nitric oxide (NO) molecules. The ions were detected with sufficient mass resolution to discriminate the species in a field of up to 10 T. This is the first experiment to succeed in the mass-selective detection of ions by the time-of-flight method in a high magnetic field. By measuring NO{sup +} ion current as a function of the laser frequency, the X{sup 2}{Pi}-A{sup 2} {Sigma}{sup +} rotational transition lines, separated clearly from the background noise, were observed in fields of up to 10 T. From the relative strengths of the transition lines, the ion detection efficiency was determined as a function of the magnetic field strength. This setup was shown to be applicable in a field higher than 10 T. The Landau levels of molecules were successfully observed to demonstrate the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗