Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Average Accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The effects of quantization on signal processing

Typically an analog signal from a space system is sampled, quantized by Analog-to-Digital (A/D) conversion, merged into a bit stream, communicated to a ground station, received by the ground station, and processed by the ground station to extract useful information for dissemination to the users. The cost of each of these steps is reduced as the number of quantization steps is reduced in the A/D converter. The number of quantization steps should be as small as possible without losing the required information content. This report deals specifically with the accuracy of averages as a function of the number of quantized samples used to compute the averages with the noise on the analog signal as a parameter. For example, the success of the Visible Infrared Spin Scan Radiometer (VISSR) Atmospheric Sounder (VAS) Demonstration depends upon temporally averaging multiple samples in an effort to reduce noise to a sufficiently low level such that temperature profile sounding is made possible. A tutorial description of this process is presented.

Montgomery, H. E.↗

Electrochemical concentration cell ozonesonde performance evaluation

A large number of electrochemical concentration cell (EDD) ozonesondes were calibrated relative to ultraviolet photometric absorption (254 nm) to determine their precision and accuracy. The average agreement with UV photometry was found to be good, but with considerable variation from one ECC ozonesonde to another. Applying individual calibrations to vertical ozone profiles reduced the systematic differences between ECC ozonesonde total ozone values and Dobson spectrophotometric determinations of the same quantity, but did not improve random differences.

Torres, A. L.↗

LANDSAT applications to wetlands classification in the upper Mississippi River Valley

A 25% improvement in average classification accuracy was realized by processing double-date vs. single-date data. Under the spectrally and spatially complex site conditions characterizing the geographical area used, further improvement in wetland classification accuracy is apparently precluded by the spectral and spatial resolution restrictions of the LANDSAT MSS. Full scene analysis of scanning densitometer data extracted from scale infrared photography failed to permit discrimination of many wetland and nonwetland cover types. When classification of photographic data was limited to wetland areas only, much more detailed and accurate classification could be made. The integration of conventional image interpretation (to simply delineate wetland boundaries) and machine assisted classification (to discriminate among cover types present within the wetland areas) appears to warrant further research to study the feasibility and cost of extending this methodology over a large area using LANDSAT and/or small scale photography.

Lillesand, T. M.↗

A comparison of Landsat point and rectangular field training sets for land-use classification

Rectangular training fields of homogeneous spectroreflectance are commonly used in supervised pattern recognition efforts. Trial image classification with manually selected training sets gives irregular and misleading results due to statistical bias. A self-verifying, grid-sampled training point approach is proposed as a more statistically valid feature extraction technique. A systematic pixel sampling network of every ninth row and ninth column efficiently replaced the full image scene with smaller statistical vectors which preserved the necessary characteristics for classification. The composite second- and third-order average classification accuracy of 50.1 percent for 331,776 pixels in the full image substantially agreed with the 51 percent value predicted by the grid-sampled, 4,100-point training set.

Tom, C. H.↗

Thermal sensing of cryogenic wind tunnel model surfaces Evaluation of silicon diodes

Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

Daryabeigi, K.↗

Continental land cover assessment using Landsat MSS data

A statistical procedure to assess level-II continental resources using Landsat MSS digital data is presented. The statistical procedure involves a two-stage cluster sample within a stratified random sample. The utility of this procedure is assessed by using it to estimate the areal extent of the conifer and hardwood resources of the continental U.S. National estimates of conifer and hardwood derived using this sampling procedure were within 3 percent of U.S. Forest Service (USFS) figures. According to the Landsat-based study, 11 percent of the country is conifer forest and 12 percent is hardwood. The corresponding USFS figures are 13 and 15 percent, respectively. Comparison of the MSS classification products and airphotos showed that the conifer cover class was correctly identified 74 percent of the time and hardwood 80 percent of the time. The average classification accuracy countrywide for the four cover types considered (conifer, hardwood, water, and 'other') is 74 percent, and the overall accuracy is 85 percent. The statistical procedure provides a method of incorporating Landsat MSS digital data as a second state for level-II continental resource assessment. Alternate data sources, e.g., satellite and aircraft photographic imagery, may also be used in conjunction with this statistical model.

Nelson, Ross↗

Thermal sensing of cryogenic wind tunnel model surfaces - Evaluation of silicon diodes

Different sensors and installation techniques for surface temperature measurement of cryogenic wind tunnel models were investigated. Silicon diodes were selected for further consideration because of their good inherent accuracy. Their average absolute temperature deviation in comparison tests with standard platinum resistance thermometers was found to be 0.2 K in the range from 125 to 273 K. Subsurface temperature measurement was selected as the installation technique in order to minimize aerodynamic interference. Temperature distortion caused by an embedded silicon diode was studied numerically.

Daryabeigi, Kamran↗

Neural controller for adaptive movements with unforeseen payloads

A theory and computer simulation of a neural controller that learns to move and position a link carrying an unforeseen payload accurately are presented. The neural controller learns adaptive dynamic control from its own experience. It does not use information about link mass, link length, or direction of gravity, and it uses only indirect uncalibrated information about payload and actuator limits. Its average positioning accuracy across a large range of payloads after learning is 3 percent of the positioning range. This neural controller can be used as a basis for coordinating any number of sensory inputs with limbs of any number of joints. The feedforward nature of control allows parallel implementation in real time across multiple joints.

Kuperstein, Michael↗

The Mars Orbiter Altimeter (MOLA) Investigation of the Shape and Topography of Mars

The Mars Orbiter Laser Altimeter (MOLA) is an instrument on the Mars Global Surveyor (MGS) spacecraft that has been orbiting Mars since September 1997. After some preliminary observations in Sept/Oct, 1997 and in the spring and summer of 1998, the MGS spacecraft entered its mapping orbit of 400 km above the surface of Mars in February 1999. MGS began a 2 year program of systematically mapping the planet with a camera (MOC), thermal emission spectrometer (TES), magnetometer (MAG), laser altimeter (MOLA), and a radio science investigation for gravity and radio occultations. MOLA has a 48mJ, 1064 nrn ND:YAG, diode pumped laser with a 8 nanosecond pulse width, a pulse rate of 10 Hz, and a range precision of less than 40 cm. MOLA has been operating almost continuously for over two years and obtained over 600 million measurements of the radius of Mars. Using very precise orbits for the MGS spacecraft derived from the Doppler and range tracking of MGS by the Deep Space Network a topographical map of Mars has been developed with an average radial accuracy of a meter and a horizontal accuracy of 100 meters. This topographical map has revealed a new Mars, a planet with some of the flattest areas in the solar system and one of the largest impact basins. MOLA has revealed clear evidence of the effect of past fluid action on the surface and found icecaps that contain as much water ice today as the icecap of Greenland.

Smith, David E.↗

Toward Malaria Risk Prediction in Afghanistan Using Remote Sensing

Malaria causes more than one million deaths every year worldwide, with most of the mortality in Sub-Saharan Africa. It is also a significant public health concern in Afghanistan, with approximately 60% of the population, or nearly 14 million people, living in a malaria-endemic area. Malaria transmission has been shown to be dependent on a number of environmental and meteorological variables. For countries in the tropics and the subtropics, rainfall is normally the most important variable, except for regions with high altitude where temperature may also be important. Afghanistan s diverse landscape contributes to the heterogeneous malaria distribution. Understanding the environmental effects on malaria transmission is essential to the effective control of malaria in Afghanistan. Provincial malaria data gathered by Health Posts in 23 provinces during 2004-2007 are used in this study. Remotely sensed geophysical parameters, including precipitation from TRMM, and surface temperature and vegetation index from MODIS are used to derive the empirical relationship between malaria cases and these geophysical parameters. Both neural network methods and regression analyses are used to examine the environmental dependency of malaria transmission. And the trained models are used for predicting future transmission. While neural network methods are intrinsically more adaptive for nonlinear relationship, the regression approach lends itself in providing statistical significance measures. Our results indicate that NDVI is the strongest predictor. This reflects the role of irrigation, instead of precipitation, in Afghanistan for agricultural production. The second strongest prediction is surface temperature. Precipitation is not shown as a significant predictor, contrary to other malarious countries in the tropics or subtropics. With the regression approach, the malaria time series are modelled well, with average R2 of 0.845. For cumulative 6-month prediction of malaria cases, the average provincial accuracy reaches 91%. The developed predictive and early warning capabilities support the Third Strategic Approach of the WHO EMRO Malaria Control and Elimination Plan.

Safi, N.↗

Comparative Analysis of NOAA REFM and SNB3GEO Tools for the Forecast of the Fluxes of High-Energy Electrons at GEO

Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB3GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB3GEO forecasts use solar wind density and interplanetary magnetic field B(sub z) observations at L1. The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB3GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB3GEO forecast.

Balikhin, M. A.↗

Development Towards Stable Chlorine Isotope Measurements of Astromaterials Using the Modified Middleton Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm3 of a typical lunar rock sample–the average cathode accuracy is ∼1‰. Cathode reproducibility is typically ∼1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ∼3–6‰ for aliquots with ∼1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

Tyler S. Anderson↗

A Privacy First Path Analysis using Clickstream Data

In the modern digital economy, data-driven decision making is crucial for effectively meeting the ever-evolving demands of consumer engagement and satisfaction. Clickstream data has become invaluable for understanding customer behavior, yet concerns over privacy and security persist, especially with some internet service providers profiting from its sale. This article introduces an innovative methodology that blends experiential learning with advanced cryptographic techniques, including differential privacy and graph analytics. The core objective of this methodology is to estimate Customer Lifetime Value (CLV) by analyzing clickstream data, achieving an average prediction accuracy of 92.4% in user engagement levels while ensuring user anonymity through Recency, Frequency, and Monetary (RFM) analysis. Our study introduces the concept of a “data depositor” and a privacy manager, employing the composition theorem to merge non-adaptive queries effectively. Privacy budgets (? = 1.0, d = 10-5), sensitivity-specific techniques, and data partitioning were applied. Randomization and noise addition protect data integrity, with special handling for categorical values. This approach, differing from prior studies, offers a 12.6% improvement in privacy-preserving targeting accuracy while maintaining strict confidentiality, presenting a novel path forward in data-driven decision-making.

Frequency and Monetary (RFM) analysis↗

Experimental validation of the TOPAS Monte Carlo system for passive scattering proton therapy

Purpose: TOPAS (TOol for PArticle Simulation) is a particle simulation code recently developed with the specific aim of making Monte Carlo simulations user-friendly for research and clinical physicists in the particle therapy community. The authors present a thorough and extensive experimental validation of Monte Carlo simulations performed with TOPAS in a variety of setups relevant for proton therapy applications. The set of validation measurements performed in this work represents an overall end-to-end testing strategy recommended for all clinical centers planning to rely on TOPAS for quality assurance or patient dose calculation and, more generally, for all the institutions using passive-scattering proton therapy systems. Methods: The authors systematically compared TOPAS simulations with measurements that are performed routinely within the quality assurance (QA) program in our institution as well as experiments specifically designed for this validation study. First, the authors compared TOPAS simulations with measurements of depth-dose curves for spread-out Bragg peak (SOBP) fields. Second, absolute dosimetry simulations were benchmarked against measured machine output factors (OFs). Third, the authors simulated and measured 2D dose profiles and analyzed the differences in terms of field flatness and symmetry and usable field size. Fourth, the authors designed a simple experiment using a half-beam shifter to assess the effects of multiple Coulomb scattering, beam divergence, and inverse square attenuation on lateral and longitudinal dose profiles measured and simulated in a water phantom. Fifth, TOPAS’ capabilities to simulate time dependent beam delivery was benchmarked against dose rate functions (i.e., dose per unit time vs time) measured at different depths inside an SOBP field. Sixth, simulations of the charge deposited by protons fully stopping in two different types of multilayer Faraday cups (MLFCs) were compared with measurements to benchmark the nuclear interaction models used in the simulations. Results: SOBPs’ range and modulation width were reproduced, on average, with an accuracy of +1, −2 and ±3 mm, respectively. OF simulations reproduced measured data within ±3%. Simulated 2D dose-profiles show field flatness and average field radius within ±3% of measured profiles. The field symmetry resulted, on average in ±3% agreement with commissioned profiles. TOPAS accuracy in reproducing measured dose profiles downstream the half beam shifter is better than 2%. Dose rate function simulation reproduced the measurements within ∼2% showing that the four-dimensional modeling of the passively modulation system was implement correctly and millimeter accuracy can be achieved in reproducing measured data. For MLFCs simulations, 2% agreement was found between TOPAS and both sets of experimental measurements. The overall results show that TOPAS simulations are within the clinical accepted tolerances for all QA measurements performed at our institution. Conclusions: Our Monte Carlo simulations reproduced accurately the experimental data acquired through all the measurements performed in this study. Thus, TOPAS can reliably be applied to quality assurance for proton therapy and also as an input for commissioning of commercial treatment planning systems. This work also provides the basis for routine clinical dose calculations in patients for all passive scattering proton therapy centers using TOPAS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stochastic analog neutron transport with TRIPOLI-4 and FREYA: Bayesian uncertainty quantification for neutron multiplicity counting

From nuclear safeguards to homeland security applications, the need for the better modeling of nuclear interactions has grown over the past decades. Current Monte Carlo radiation transport codes compute average quantities with great accuracy and performance; however, performance and averaging come at the price of limited interaction-by-interaction modeling. These codes often lack the capability of modeling interactions exactly: for a given collision, energy is not conserved, energies of emitted particles are uncorrelated, and multiplicities of prompt fission neutrons and photons are uncorrelated. Many modern applications require more exclusive quantities than averages, such as the fluctuations in certain observables (e.g., the neutron multiplicity) and correlations between neutrons and photons. In an effort to meet this need, the radiation transport Monte Carlo code TRIPOLI-4® was modified to provide a specific mode that models nuclear interactions in a full analog way, replicating as much as possible the underlying physical process. Furthermore, the computational model FREYA (Fission Reaction Event Yield Algorithm) was coupled with TRIPOLI-4 to model complete fission events. As a result, FREYA automatically includes fluctuations as well as correlations resulting from conservation of energy and momentum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

Non-NASA Center↗

Physics-Informed Deep Learning for Reconstruction of Spatial Missing Climate Information in the Antarctic

Understanding the influence of the Antarctic on the global climate is crucial for the prediction of global warming. However, due to very few observation sites, it is difficult to reconstruct the rational spatial pattern by filling in the missing values from the limited site observations. To tackle this challenge, regional spatial gap-filling methods, such as Kriging and inverse distance weighted (IDW), are regularly used in geoscience. Nevertheless, the reconstructing credibility of these methods is undesirable when the spatial structure has massive missing pieces. Inspired by image inpainting, we propose a novel deep learning method that demonstrates a good effect by embedding the physics-aware initialization of deep learning methods for rapid learning and capturing the spatial dependence for the high-fidelity imputation of missing areas. We create the benchmark dataset that artificially masks the Antarctic region with ratios of 30%, 50% and 70%. The reconstructing monthly mean surface temperature using the deep learning image inpainting method RFR (Recurrent Feature Reasoning) exhibits an average of 63% and 71% improvement of accuracy over Kriging and IDW under different missing rates. With regard to wind speed, there are still 36% and 50% improvements. In particular, the achieved improvement is even better for the larger missing ratio, such as under the 70% missing rate, where the accuracy of RFR is 68% and 74% higher than Kriging and IDW for temperature and also 38% and 46% higher for wind speed. In addition, the PI-RFR (Physics-Informed Recurrent Feature Reasoning) method we proposed is initialized using the spatial pattern data simulated by the numerical climate model instead of the unified average. Compared with RFR, PI-RFR has an average accuracy improvement of 10% for temperature and 9% for wind speed. When applied to reconstruct the spatial pattern based on the Antarctic site observations, where the missing rate is over 90%, the proposed method exhibits more spatial characteristics than Kriging and IDW.

54 ENVIRONMENTAL SCIENCES↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗