Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Attack localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Flight test results from a supercritical mission adaptive wing with smooth variable camber

The mission adaptive wing (MAW) consisted of leading- and trailing-edge variable-camber surfaces that could be deflected in flight to provide a near-ideal wing camber shape for any flight condition. These surfaces featured smooth, flexible upper surfaces and fully enclosed lower surfaces, distinguishing them from conventional flaps that have discontinuous surfaces and exposed or semiexposed mechanisms. Camber shape was controlled by either a manual or automatic flight control system. The wing and aircraft were extensively instrumented to evaluate the local flow characteristics and the total aircraft performance. This paper discusses the interrelationships between the wing pressure, buffet, boundary-layer and flight deflection measurement system analyses and describes the flight maneuvers used to obtain the data. The results are for a wing sweep of 26 deg, a Mach number of 0.85, leading and trailing-edge cambers (delta(sub LE/TE)) of 0/2 and 5/10, and angles of attack from 3.0 deg to 14.0 deg. For the well-behaved flow of the delta(sub LE/TE) = 0/2 camber, a typical cruise camber shape, the local and global data are in good agreement with respect to the flow properties of the wing. For the delta(sub LE/TE) = 5/10 camber, a maneuvering camber shape, the local and global data have similar trends and conclusions, but not the clear-cut agreement observed for cruise camber.

Powers, Sheryll Goecke↗

Results of a study of Mach number and Reynolds number effects on the lee side vortex flow field characteristics of an ogive-cylinder-frustum-cylinder at angles of attack to 25 degrees, volume 1

An experimental program was conducted to survey the lee side vortex flow field about an ogive-cylinder-frustum-cylinder at angles of attack to 25 degrees for two Reynolds numbers at Mach number 0.8, and one Reynolds number at Mach number 1.96. The data were obtained using miniature 5-port conical pressure probes calibrated for angle of attack and roll angle over a Mach number range of 0.6 to 3.0. The results are presented here as local flow field properties and circulation strengths for various body stations.

Foley, J. E.↗

Numerical simulation of an F-16A at angle of attack

The transonic flowfield around an F-16A fighter configuration at a moderate incidence angle is simulated by solving the Navier-Stokes equations on a single-block grid. The numerical solution matches experimental freestream conditions with a mach number of 0.85, 16 degrees angle of attack, and a characteristic Reynolds number of 12.75 million. MacCormack's explicit algorithm is used in conjuction with a local time step and consecutive mesh refinement procedure to accelerate numerical convergence. The Baldwin-Lomax algebraic model provides turbulent closure. Computed surface pressure distributions and the aircraft lift coefficient compare favorably with wind tunnel data. The drag coefficient in the simulation overpredicts the experimental value by 8 percent.

Huband, G. W.↗

A Model for Ice Accretion Roughness Evolution and Spatial Variations

Over the past decade, multiple investigations of ice accretion roughness and spatial variations have been performed in the Icing Research Tunnel (IRT) at the NASA Glenn Research Center. The early investigations used models of NACA 0012 airfoils with different chord sizes and focused on temporal scaling and primary cloud scaling parameters such as stagnation point collection efficiency. Subsequent investigations included the effects of model sweep, airfoil shape, airfoil lifting condition, and freestream static temperature. To develop a predictive model for roughness evolution in generalized icing situations, the maximum roughness values for the airfoils and conditions used in the angle of attack and freestream temperature investigations were scaled to eliminate the temporal variations. LEWICE simulations were employed to identify the local collection efficiency at the locations of maximum roughness, and a two-dimensional panel-method code was used to identify the local static pressure at the location of the maximum roughness. Because of the stochastic nature of ice accretion roughness, a physics-directed approach was employed to develop a multi-dimensional correlation based on the local pressure coefficient, the local total temperature, the cloud properties, and the cloud exposure time. The resulting correlation predictions are compared to ice shapes measured in the IRT for both a 21-in. NACA 0012 airfoil model and a 60-in. HAARP-II model. The resulting predictions indicate that the local freezing fraction must be included in the roughness predictive model. Implications regarding icing heat transfer predictions using the resulting roughness model are also discussed.

Icing↗

Federated Machine Learning-Based Anomaly Detection System for Synchrophasor Network Using Heterogeneous Data Sets: Preprint

Synchrophasor technology is widely deployed in the energy management system to monitor the grid health at micro level and perform necessary corrective actions in real time; however, integrated phasor devices and data aggregators are exposed to several cybersecurity threats. This paper proposes a federated ML(FML)-based ADS to detect several data integrity attacks in the synchrophasor network. The proposed approach integrates the horizontal FML technique and consists of substation-based local models and a control center-based global model. The proposed methodology includes training local models using heterogeneous data sets that include network and grid information and updating the global model through multiple iterations by sharing model gradients. Finally, the trained global model is applied to identify cyberattacks, normal operation, and physical events. To validate the proof of concept, we used synthetic data sets generated by Mississippi State University and Oak Ridge National Laboratory for training and testing the classification models using the National Renewable Energy Laboratory's high performance computing resources. Our experimental results, computed through several performance measures, reveal that the proposed approach shows consistent performance during the binary, three-class, and multiclass classifications while ensuring privacy of synchrophasor data.

anomaly detection system↗

The effects of rotational flow, viscosity, thickness, and shape on transonic flutter dip phenomena

The transonic flutter dip phenomena on thin airfoils, which are employed for propfan blades, is investigated using an integrated Euler/Navier-Stokes code and a two degrees of freedom typical section structural model. As a part of the code validation, the flutter characteristics of the NACA 64A010 airfoil are also investigated. In addition, the effects of artificial dissipation models, rotational flow, initial conditions, mean angle of attack, viscosity, airfoil thickness and shape on flutter are investigated. The results obtained with a Euler code for the NACA 64A010 airfoil are in reasonable agreement with published results obtained by using transonic small disturbance and Euler codes. The two artificial dissipation models, one based on the local pressure gradient scaled by a common factor and the other based on the local pressure gradient scaled by a spectral radius, predicted the same flutter speeds except in the recovery region for the case studied. The effects of rotational flow, initial conditions, mean angle of attack, and viscosity for the Reynold's number studied seem to be negligible or small on the minima of the flutter dip.

Reddy, T. S. R.↗

The effects of rotational flow, viscosity, thickness, and shape on transonic flutter dip phenomena

The transonic flutter dip phenomena on thin airfoils, which are employed for propfan blades, is investigated using an integrated Euler/Navier-Stokes code and a two degrees of freedom typical section structural model. As a part of the code validation, the flutter characteristics of the NACA 64A010 airfoil are also investigated. In addition, the effects of artificial dissipation models, rotational flow, initial conditions, mean angle of attack, viscosity, airfoil thickness, and shape on flutter are investigated. The results obtained with an Euler code for the NACA 64A010 airfoil are in reasonable agreement with published results obtained by using transonic small disturbance and Euler codes. The two artifical dissipation models, one based on the local pressure gradient scaled by a common factor and the other based on the local presure gradient scaled by a spectral radius, predicted the same flutter speeds except in the recovery region for the case studied. The effects of rotation flow, initial conditions, mean angle of attack, and viscosity for the Reynolds number studied seem to be negligible or small on the minima of the flutter dip.

Reddy, T. S. R.↗

Digital Twin for Self-Security of Smart Inverters

Smart inverters connected to a communication network are susceptible to man-in-the-middle attacks. In this paper, a self-security approach is implemented using the digital twin concept for smart inverters. The digital twin is formed using the inverter’s normal operating region and the inverter’s dynamic model. Then, the incoming setpoints are autonomously examined using the digital twin, and only the safe setpoints are engaged to the inverter’s local controller. This paper demonstrates how the inverter’s normal operating region and dynamic model are formed. In particular, the normal operation region is experimentally verified by changing the P and Q setpoints engaged to the local controller, using a laboratory setup including a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative power grid emulator. The results demonstrate that the self-security technique can potentially protect inverters from man-in-the-middle attacks by examining the incoming commands (new setpoints) using the inverter’s digital twin before engaging the setpoints to the local controller.

Hossen, Tareq↗

Breaking down the delta wing vortex: The role of vorticity in the breakdown process

Experimental x-wire measurements of the flowfield above a 70 degree and 75 degree flat plate delta wing were performed at a Reynolds number of 250,000. Grids were taken normal to the wing at various chordwise locations for angles of attack of 20 degrees and 30 degrees. Axial and azimuthal vorticity distributions were derived from the velocity fields. The dependence of circulation on distance from the vortex core and on chordwise location was also examined. The effects of nondimensionalization in comparison with other experimental data is made. The results indicate that the circulation distribution scales with the local semispan and grows in a nearly linear fashion in the chordwise direction. The spanwise distribution of axial vorticity is severely altered through the breakdown region and the amount of vorticity present appears to reach a maximum immediately preceding breakdown. The axial velocity components with a negative sense, such as that found in the secondary vortex, seem to remain unaffected by changes in wing sweep or angle of attack, in direct contrast to the visible components. In addition, the inclusion of the local wing geometry into a previously derived correlation parameter allows the circulation of growing leading edge vortex flows to be reduced to a single curve.

Nelson, R. C.↗

Venting characteristics of gaseous helium and nitrogen discharging into a free stream at Mach numbers from 0.60 to 1.57

An experimental investigation was conducted in the Lewis Research Center 8- by 6-Foot Supersonic Wind Tunnel to compare the effects on discharge coefficient of venting gaseous helium and gaseous nitrogen into a free stream. The test was conducted from Mach 0.06 to 1.57 with the vent mounted in a flat plate. The plate was strut mounted to the tunnel ceiling and at a 0 angle of attack. The gases were discharged from a plenum chamber through a 2.54-centimeter (1.00-in.) diameter vent. The ratio of local static pressure to plenum pressure was varied from 0.51 to 0.975. The ratio of boundary layer thickness to vent diameter varied from a maximum of 1.34 at Mach 0.60 to a minimum of 0.55 at Mach 1.37.

Johns, A. L.↗

General Characteristics of a Airspeed System using Fuselage Static Vents on a Swept-Wing Airplane

Studies have been made by the NACA wing-flow method of the use of fuselage static orifices between the wing and tail of a swept-wing airplane for possible application to service airspeed installations. The tests were made at zero angle of attack. The results indicate that, although the maximum errors are large, these locations are usable from the consideration that the local Mach numbers at the locations studied are sensitive to variation of the true Mach number within the test Mach number range of 0.7 to 1.2. The maximum errors in Mach number in the subsonic range varied from zero for the most forward location to -0.05 for the most rearward location (indicated Mach number less than true). At Mach numbers above 1.0, the maximum errors were from 0.14 for the most forward location to 0.04 for the most rearward location.

Johnston, J. Ford↗

Delta wing surface pressures for high angle of attack maneuvers

A wind tunnel experiment was performed on a delta wing with a leading edge sweep of 70 deg. Unsteady pressures were measured on the suction surface of the wing as it was oscillated from 0-30 deg, and 2-60 deg angle-of-attack. Pressure coefficients were measured at different surface locations for two pitch rates. Static pressure measurements were also obtained for comparison with the dynamic results. The Reynolds number was fixed at 420,000, based on the centerline chord length. Pressure measurements were made from 35-90 percent of the chord, along a ray from the apex at 60 percent of the local semispan. Spanwise measurements were also made at a constant chord location, x/c = 75 percent from the apex. The unsteady pressure data over the 0-30 deg angle-of-attack range showed pressures fluctuating in phase with model motion, and little overshoot from the static values. The pressures for the large amplitude motion showed large overshoots from the static values. In addition, during the high angle-of-attack portion of the motion, the upstroke (angle of attack increasing) pressure coefficients were typically much lower than the downstroke values. For the lower pitch rate, there was little difference between upstroke and downstroke pressures at the low angles of attack.

Thompson, S. A.↗

Impact of cyber attacks on distributed compressive sensing based state estimation in power distribution grids

Modern power distribution grids suffer from multiple vulnerabilities due to the tight integration between the physical system and the cyber infrastructure. Sophisticated and malicious cyber attacks continue to adversely impact the grid operation leading to performance degradation, service interruption, and grid failure. State estimation plays an essential role in grid monitoring and advancing cyber-attack situational awareness. In this regard, this paper first proposes a distributed compressive sensing (CS) state estimation approach for an unobservable distribution grid. Further, the proposed distributed CS approach divides the distribution grid into sub-areas to perform local state estimation. Then an alternating direction method of multipliers (ADMM) based iterative information exchange among neighboring areas is employed to complete the estimation process. In this estimation process, the impact of loss of measurement data, false data injection (FDI), replay, and neighborhood cyber-attacks is analyzed. Extensive simulations are performed on the IEEE 37-bus and IEEE 123-bus standard networks to demonstrate the algorithm’s robustness to the aforementioned cyber-attacks. A quantitative analysis of computational complexity and simulation time of the distributed CS based approach is also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of wall cooling and angle of attack on boundary layer transition on sharp cones at free stream Mach 7.4

Tests were conducted on 5 deg and 15 deg half-angle sharp cones at wall-to-total-temperature ratios of 0.08 to 0.4, and angles of attack from 0 deg to 20 deg. The results indicate that (1) transition Reynolds numbers decrease with decreasing temperature ratio, (2) local transition Reynolds numbers decrease from the windward to the leeward side of the model, and (3) transition data on the windward ray of cones can be correlated in terms of the crossflow velocity gradient, momentum thickness Reynolds number, local Mach number, and cone half-angle.

Mateer, G. G.↗

Hypersonic vehicle simulation model: Winged-cone configuration

Aerodynamic, propulsion, and mass models for a generic, horizontal-takeoff, single-stage-to-orbit (SSTO) configuration are presented which are suitable for use in point mass as well as batch and real-time six degree-of-freedom simulations. The simulations can be used to investigate ascent performance issues and to allow research, refinement, and evaluation of integrated guidance/flight/propulsion/thermal control systems, design concepts, and methodologies for SSTO missions. Aerodynamic force and moment coefficients are given as functions of angle of attack, Mach number, and control surface deflections. The model data were estimated by using a subsonic/supersonic panel code and a hypersonic local surface inclination code. Thrust coefficient and engine specific impulse were estimated using a two-dimensional forebody, inlet, nozzle code and a one-dimensional combustor code and are given as functions of Mach number, dynamic pressure, and fuel equivalence ratio. Rigid-body mass moments of inertia and center of gravity location are functions of vehicle weight which is in turn a function of fuel flow.

Shaughnessy, John D.↗

Sharp flat plate heat transfer in helium at Mach numbers of 22.8 to 86.8 and in corner flow with air at Mach number of 19

Surface heat transfer rates were measured on a sharp flat plate at zero angle of attack in a hypersonic shock tunnel. The density and leading edge Knudsen number were varied to span the continuum to near free molecule regimes. The strong interaction parameter varied from 11 to 16,000 with Knudsen numbers from 0.56 to 17.1 respectively. Local heat transfer rates in the corner flow region produced by the intersection of two perpendicular flat plates with sharp leading edges were determined for various flow densities. The strength of the shock wave from the vertical plate was varied by adjusting the angle of attack from 0 to 5 deg. The unit Reynolds number varied from 1,000 to 17,200 and the Knudsen numbers from 1.6 to 27. The strong interaction parameter varied from 14 to 500.

Nagamatsu, H. T.↗

Control of Flow Separation Using Adaptive Airfoils

A novel way of controlling flow separation is reported. The approach involves using an adaptive airfoil geometry that changes its leading edge shape to adjust to the instantaneous flow at high angles of attack such that the flow over it remains attached. In particular, a baseline NACA 0012 airfoil, whose leading edge curvature could be changed dynamically by 400% was tested under quasi-steady compressible flow conditions. A mechanical drive system was used to produce a rounded leading edge to reduce the strong local flow acceleration around its nose and thus reduce the strong adverse pressure gradient that follows such a rapid acceleration. Tests in steady flow showed that at M = 0.3, the flow separated at about 14 deg. angle of attack for the NACA 0012 profile but could be kept attached up to an angle of about 18 deg by changing the nose curvature. No significant hysteresis effects were observed; the flow could be made to reattach from its separated state at high angles by changing the leading edge curvature. Interestingly, the flow over a nearly semicircular nosed airfoil was separated even at low angles.

Chandrasekhara, M. S.↗

Control of Flow Separation Using Adaptive Airfoils

A novel way of controlling flow separation is reported. The approach involves using an adaptive airfoil geometry that changes its leading edge shape to adjust to the instantaneous flow at high angles of attack such that the flow over it remains attached. In particular, a baseline NACA 0012 airfoil, whose leading edge curvature could be changed dynamically by 400% was tested under quasi-steady compressible flow conditions. A mechanical drive system was used to produce a rounded leading edge to reduce the strong local flow acceleration around its nose and thus reduce the strong adverse pressure gradient that follows such a rapid acceleration. Tests in steady flow showed that at M = 0.3, the flow separated at about 14 deg. angle of attack for the NACA 0012 profile but could be kept attached up to an angle of about 18 deg by changing the nose curvature. No significant hysteresis effects were observed; the flow could be made to reattach from its separated state at high angles by changing the leading edge curvature.

Chandrasekhara, M. S.↗