Measurement of jet quenching with semi-inclusive hadron-jet distributions in central Pb-Pb collisions at $\sqrt{s_{NN}}$ =2.76 TeV

We report the measurement of a new observable of jet quenching in central Pb-Pb collisions at $ \sqrt{s_{\mathrm{NN}}}=2.76 $ TeV, based on the semi-inclusive rate of charged jets recoiling from a high transverse momentum (high-p T) charged hadron trigger. Jets are measured using collinear-safe jet reconstruction with infrared cutoff for jet constituents of 0.15 GeV, for jet resolution parameters R = 0.2, 0.4 and 0.5. Underlying event background is corrected at the event-ensemble level, without imposing bias on the jet population. Recoil jet spectra are reported in the range 20 < p T,jet ch < 100 GeV. Reference distributions for pp collisions at $ \sqrt{s}=2.76 $ TeV are calculated using Monte Carlo and NLO pQCD methods, which are validated by comparing with measurements in pp collisions at $ \sqrt{s}=7 $ TeV. The recoil jet yield in central Pb-Pb collisions is found to be suppressed relative to that in pp collisions. No significant medium-induced broadening of the intra-jet energy profile is observed within 0.5 radians relative to the recoil jet axis. Additionally, the angular distribution of the recoil jet yield relative to the trigger axis is found to be similar in central Pb-Pb and pp collisions, with no significant medium-induced acoplanarity observed. Large-angle jet deflection, which may provide a direct probe of the nature of the quasi-particles in hot QCD matter, is explored.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A deterministic solution of the first order linear Boltzmann transport equation in the presence of external magnetic fields

Purpose: Accurate radiotherapy dose calculation algorithms are essential to any successful radiotherapy program, considering the high level of dose conformity and modulation in many of today’s treatment plans. As technology continues to progress, such as is the case with novel MRI-guided radiotherapy systems, the necessity for dose calculation algorithms to accurately predict delivered dose in increasingly challenging scenarios is vital. To this end, a novel deterministic solution has been developed to the first order linear Boltzmann transport equation which accurately calculates x-ray based radiotherapy doses in the presence of magnetic fields. Methods: The deterministic formalism discussed here with the inclusion of magnetic fields is outlined mathematically using a discrete ordinates angular discretization in an attempt to leverage existing deterministic codes. It is compared against the EGSnrc Monte Carlo code, utilizing the emf-macros addition which calculates the effects of electromagnetic fields. This comparison is performed in an inhomogeneous phantom that was designed to present a challenging calculation for deterministic calculations in 0, 0.6, and 3 T magnetic fields oriented parallel and perpendicular to the radiation beam. The accuracy of the formalism discussed here against Monte Carlo was evaluated with a gamma comparison using a standard 2%/2 mm and a more stringent 1%/1 mm criterion for a standard reference 10 × 10 cm{sup 2} field as well as a smaller 2 × 2 cm{sup 2} field. Results: Greater than 99.8% (94.8%) of all points analyzed passed a 2%/2 mm (1%/1 mm) gamma criterion for all magnetic field strengths and orientations investigated. All dosimetric changes resulting from the inclusion of magnetic fields were accurately calculated using the deterministic formalism. However, despite the algorithm’s high degree of accuracy, it is noticed that this formalism was not unconditionally stable using a discrete ordinate angular discretization. Conclusions: The feasibility of including magnetic field effects in a deterministic solution to the first order linear Boltzmann transport equation is shown. The results show a high degree of accuracy when compared against Monte Carlo calculations in all magnetic field strengths and orientations tested.

60 APPLIED LIFE SCIENCES↗

Local spin polarizations in relativistic heavy-ion collisions

Here, based on a generalized side-jump formalism for massless chiral fermions, which naturally takes into account the spin-orbit coupling in the scattering of two chiral fermions and the chiral vortical effect in a rotating chiral fermion matter, we have developed a covariant and total-angular-momentum-conserved chiral transport model to study both the global and local polarizations of this matter. For a system of massless quarks of random spin orientations and finite vorticity in a box, we have demonstrated that the model can exactly conserve the total angular momentum of the system and dynamically generate the quark spin polarization expected from a thermally equilibrated quark matter. Using this model to study the spin polarization in relativistic heavy-ion collision, we have found that the local quark spin polarizations depend strongly on the reference frame where they are evaluated as a result of the nontrivial axial charge distribution caused by the chiral vortical effect. We have further shown that because of the anomalous orbital or side-jump contribution to the quark spin polarization, the local quark polarizations calculated in the medium rest frame are qualitatively consistent with the local polarizations of Lambda hyperons measured in experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angular decay coefficients of J/ψ mesons at forward rapidity from p+p collisions at √s = 510 GeV

In this paper, we report the first measurement of the full angular distribution for inclusive J/ψ → μ + μ - decays in p+p collisions at √s = 510 GeV. The measurements are made for J/ψ transverse momentum 2 < p T < 10 GeV/c and rapidity 1.2 < y < 2.2 in the Helicity, Collins-Soper, and Gottfried-Jackson reference frames. In all frames the polar coefficient λ θ is strongly negative at low p T and becomes close to zero at high p T , while the azimuthal coefficient λ Φ is close to zero at low p T , and becomes slightly negative at higher p T . The frame-independent coefficient λ ~ is strongly negative at all p T in all frames. Finally, the data are compared to the theoretical predictions provided by nonrelativistic quantum chromodynamics models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Shielding implications for secondary neutrons and photons produced within the patient during IMPT

Purpose: Intensity modulated proton therapy (IMPT) uses a combination of computer controlled spot scanning and spot-weight optimized planning to irradiate the tumor volume uniformly. In contrast to passive scattering systems, secondary neutrons and photons produced from inelastic proton interactions within the patient represent the major source of emitted radiation during IMPT delivery. Various published studies evaluated the shielding considerations for passive scattering systems but did not directly address secondary neutron production from IMPT and the ambient dose equivalent on surrounding occupational and nonoccupational work areas. Thus, the purpose of this study was to utilize Monte Carlo simulations to evaluate the energy and angular distributions of secondary neutrons and photons following inelastic proton interactions within a tissue-equivalent phantom for incident proton spot energies between 70 and 250 MeV.Methods: Monte Carlo simulation methods were used to calculate the ambient dose equivalent of secondary neutrons and photons produced from inelastic proton interactions in a tissue-equivalent phantom. The angular distribution of emitted neutrons and photons were scored as a function of incident proton energy throughout a spherical annulus at 1, 2, 3, 4, and 5 m from the phantom center. Appropriate dose equivalent conversion factors were applied to estimate the total ambient dose equivalent from secondary neutrons and photons.Results: A reference distance of 1 m from the center of the patient was used to evaluate the mean energy distribution of secondary neutrons and photons and the resulting ambient dose equivalent. For an incident proton spot energy of 250 MeV, the total ambient dose equivalent (3.6 Multiplication-Sign 10{sup -3} mSv per proton Gy) was greatest along the direction of the incident proton spot (0 Degree-Sign -10 Degree-Sign ) with a mean secondary neutron energy of 71.3 MeV. The dose equivalent decreased by a factor of 5 in the backward direction (170 Degree-Sign -180 Degree-Sign ) with a mean energy of 4.4 MeV. An 8 Multiplication-Sign 8 Multiplication-Sign 8 cm{sup 3} volumetric spot distribution (5 mm FWHM spot size, 4 mm spot spacing) optimized to produce a uniform dose distribution results in an ambient dose equivalent of 4.5 Multiplication-Sign 10{sup -2} mSv per proton Gy in the forward direction.Conclusions: This work evaluated the secondary neutron and photon emission due to monoenergetic proton spots between 70 and 250 MeV, incident on a tissue equivalent phantom. Example calculations were performed to estimate concrete shield thickness based upon appropriate workload and shielding design assumptions. Although lower than traditional passive scattered proton therapy systems, the ambient dose equivalent from secondary neutrons produced by the patient during IMPT can be significant relative to occupational and nonoccupational workers in the vicinity of the treatment vault. This work demonstrates that Monte Carlo simulations are useful as an initial planning tool for studying the impact of the treatment room and maze design on surrounding occupational and nonoccupational work areas.

61 RADIATION PROTECTION AND DOSIMETRY↗

Frequency-Domain Streak Camera and Tomography for Ultrafast Imaging of Evolving and Channeled Plasma Accelerator Structures

We demonstrate a prototype Frequency Domain Streak Camera (FDSC) that can capture the picosecond time evolution of the plasma accelerator structure in a single shot. In our prototype Frequency-Domain Streak Camera, a probe pulse propagates obliquely to a sub-picosecond pump pulse that creates an evolving nonlinear index 'bubble' in fused silica glass, supplementing a conventional Frequency Domain Holographic (FDH) probe-reference pair that co-propagates with the 'bubble'. Frequency Domain Tomography (FDT) generalizes Frequency-Domain Streak Camera by probing the 'bubble' from multiple angles and reconstructing its morphology and evolution using algorithms similar to those used in medical CAT scans. Multiplexing methods (Temporal Multiplexing and Angular Multiplexing) improve data storage and processing capability, demonstrating a compact Frequency Domain Tomography system with a single spectrometer.

43 PARTICLE ACCELERATORS↗

Modeling of current characteristics of segmented Langmuir probe on DEMETER

We model the current characteristics of the DEMETER Segmented Langmuir probe (SLP). The probe is used to measure electron density and temperature in the ionosphere at an altitude of approximately 700 km. It is also used to measure the plasma flow velocity in the satellite frame of reference. The probe is partitioned into seven collectors: six electrically insulated spherical segments and a guard electrode (the rest of the sphere and the small post). Comparisons are made between the predictions of the model and DEMETER measurements for actual ionospheric plasma conditions encountered along the satellite orbit. Segment characteristics are computed numerically with PTetra, a three-dimensional particle in cell simulation code. In PTetra, space is discretized with an unstructured tetrahedral mesh, thus, enabling a good representation of the probe geometry. The model also accounts for several physical effects of importance in the interaction of spacecraft with the space environment. These include satellite charging, photoelectron, and secondary electron emissions. The model is electrostatic, but it accounts for the presence of a uniform background magnetic field. PTetra simulation results show different characteristics for the different probe segments. The current collected by each segment depends on its orientation with respect to the ram direction, the plasma composition, the magnitude, and the orientation of the magnetic field. It is observed that the presence of light H{sup +} ions leads to a significant increase in the ion current branch of the I-V curves of the negatively polarized SLP. The effect of the magnetic field is demonstrated by varying its magnitude and direction with respect to the reference magnetic field. It is found that the magnetic field appreciably affects the electron current branch of the I-V curves of certain segments on the SLP, whereas the ion current branch remains almost unaffected. PTetra simulations are validated by comparing the computed characteristics and their angular anisotropy with the DEMETER measurements, as simulation results are found to be in good agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-of-flight Extreme Environment Diffractometer at the Helmholtz-Zentrum Berlin

The Extreme Environment Diffractometer (EXED) is a new neutron time-of-flight instrument at the BER II research reactor at the Helmholtz-Zentrum Berlin, Germany. Although EXED is a special-purpose instrument, its early construction made it available for users as a general-purpose diffractometer. In this respect, EXED became one of the rare examples, where the performance of a time-of-flight diffractometer at a continuous source can be characterized. In this paper, we report on the design and performance of EXED with an emphasis on the unique instrument capabilities. The latter comprise variable wavelength resolution and wavelength band, control of the incoming beam divergence, the possibility to change the angular positions of detectors and their distance to the sample, and use of event recording and offline histogramming. These features combined make EXED easily tunable to the requirements of a particular problem, from conventional diffraction to small angle neutron scattering. The instrument performance is demonstrated by several reference measurements and user experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Autocollimators for Deflectometry: Current Status and Future Progress

The proliferation of autocollimator-based surface profilometers at synchrotron metrology laboratories worldwide necessitates a detailed understanding of the parameters influencing their angular response. A comprehensive overview of the current status of autocollimator characterization and calibration at the Physikalisch-Technische Bundesanstalt (PTB) and its implications for their optimal application are provided, as well as information on future challenges and expected progress. Autocollimator-based deflectometric profilometers are in operation at the PTB, the Advanced Light Source (ALS), Lawrence Berkeley National Laboratory, USA, the BESSY II, Helmholtz-Zentrum Berlin fuer Materialien und Energie GmbH, Germany, and the Diamond Light Source Ltd (DLS), UK. A continuous topic of research at the PTB is to investigate the factors influencing the angular response of autocollimators and to provide the most accurate calibration of the instruments to aid users in their application and manufacturers in their improvements [1-3]. At the PTB, the calibration of autocollimators is realized by a direct comparison of the devices with the primary angle reference standard [1]. With highly stable autocollimators, calibrations with standard measurement uncertainties of u = 0.003 arcsec (15 nrad) have been achieved [2,3]. The influence of a number of parameters on the angle measurement with autocollimators have been investigated in detail, such as the reflectivity of the surface under test (SUT), the diameter and shape of the aperture stop, its position both along the autocollimator's optical axis and perpendicular to it [2], as well as the optical path length of the autocollimator beam [3]. Extensive information on these errors and their minimization will be presented.

47 OTHER INSTRUMENTATION↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

First-collision source treatment for ray effect mitigation in discrete-ordinate radiation transport solutions

Deterministic transport codes play a fundamental role in the modelling and simulation of neutron transport. One of the most common deterministic methods is the method of discrete ordinates, also known as the S method. While offering significant advantages over other deterministic methods or stochastic methods like Monte Carlo, the method of discrete ordinates suffers from non-physical artifacts in its local solution due to its discretization of angle. These artifacts, referred to as ray effects because of their ray-like appearance, tend to be worse in problems with small sources in areas with little scattering. Significant effort has gone into developing methods to mitigate ray effects, such as the first-collision source treatment, which separates the angular flux into the uncollided and collided fluxes and solving them using non-traditional techniques such as ray tracing. One such code capable of doing this is Lawrence Livermore National Laboratory's deterministic transport code ARDRA. Current ray tracing methods typically trace to a set of points inside a zone to compute an overall flux. However, this approach has significant drawbacks, such as a low order of convergence and not being conservative. Therefore, a new method has been developed that traces instead to a set of points on each of a zone's surfaces and computing the currents, before using these to obtain the flux. A comparison between these two ray tracing methods showed significant advantages to the new surface method, including inherent conservation, a higher convergence rate, and an increase in calculable information like leakage. This work performed under the auspices of the U.S. Department of Energy by Lawrence Liver- more National Laboratory under Contract DE-AC52-07NA27344. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of differential cross sections for the production of a pair of isolated photons in pp collisions at √s=7TeV

A measurement of differential cross sections for the production of a pair of isolated photons in proton–proton collisions at √s=7TeV is presented. The data sample corresponds to an integrated luminosity of 5.0fb -1 collected with the CMS detector. A data-driven isolation template method is used to extract the prompt diphoton yield. The measured cross section for two isolated photons, with transverse energy above 40 and 25GeV respectively, in the pseudorapidity range |η|<2.5, |η|ϵ[1.44,1.57] and with an angular separation ΔR>0.45, is 17.2±0.2(stat)±1.9(syst)±0.4(lumi) \,pb. Differential cross sections are measured as a function of the diphoton invariant mass, the diphoton transverse momentum, the azimuthal angle difference between the two photons, and the cosine of the polar angle in the Collins–Soper reference frame of the diphoton system. The results are compared to theoretical predictions at leading, next-to-leading, and next-to-next-to-leading order in quantum chromodynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Beam Spin Asymmetries in p+p0 and p´p0 Dihadron Production at CLAS12

Semi-Inclusive Deep Inelastic Scattering (SIDIS) is a powerful experimental tool for studying the internal structure and dynamics of the proton, revealing how quarks and gluons are distributed and interact within it. SIDIS describes a process where an elec tron scatters off one of the constituent quarks within the proton, causing it to undergo hadronization, creating multiple hadrons in the final state. Through factorization, the full process can be split into probabilistic components: one which describes the internal structure of the proton using Parton Distribution Functions (PDFs), and another which describes the hadronization process using Fragmentation Functions (FFs). These functions are non-perturbative quantities of Quantum Chromodynamics (QCD), meaning they cannot be calculated directly from first principles and must instead be extracted from experimental measurements. Acommon approach for accessing PDFs and FFs using SIDIS is to measure asymmetries. In this context, asymmetries correspond to subtle differences in the angular distribution of outgoing particles that arise when the spin orientation of the incoming beam or target is reversed. Because many of these effects only appear when spin is involved, they isolate specific, nuanced properties of the proton’s spin-structure that are otherwise hidden in spin averaged measurements. In practice, they show up as specific azimuthal modulations (e.g., sin ¿R, sin(¿h ´ ¿R)), whose amplitudes isolate convolutions of PDFs and FFs at leading and subleading twist. Non-zero asymmetries of these angular distributions can be traced back to unique combinations of PDFs and FFs, offering a way to probe them directly. In this work, we measure SIDIS by analyzing high energy electron-proton scattering events using the CLAS12 detector at Jefferson Lab. This study focuses on subset of SIDIS referred to as dihadron SIDIS, where pairs of hadrons — here p+p0 and p´p0 — are observed. We analyzed these dihadrons using detector data collected during Fall 2018 and Spring 2019, where longitudinally polarized electrons from the CEBAF accelerator were incident on a liquid hydrogen target. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained using Monte Carlo simulations to reduce the amount of iv false combinatorial background p0’s. When deployed on experimental data, the model in creases our dihadron statistics by up to five-fold compared to previous CLAS12 p0 analyses. This work reports the first measurements of beam spin asymmetries for p+p0 and p´p0 dihadron production in SIDIS. The measured asymmetries offer new insights to the spin-dependent structure and dynamics within the proton, as well as the spin-dependent properties of quark fragmentation. Non-zero twist-3 sin¿R amplitudes are observed, pro viding sensitivity to the subleading twist PDF e(x). The PDF e(x) encodes quark-gluon correlations within the proton — a property that is otherwise inaccessible at leading twist. Additionally, this work measured significant twist-2 modulations carried by sin(¿h ´ ¿R) and sin(2¿h ´2¿R), providing experimental access to the helicity dihadron fragmentation function (DiFF) GK 1 . Because there is no equivalent quark helicity-dependent FF in single pion SIDIS, the DiFF GK 1 offers a unique lens into novel spin-dependent fragmentation. For instance, the twist-2 modulations observed in this study are enhanced by vector mesons created during fragmentation — a behavior predicted by phenomenological models. This study broadens our understanding of dihadron fragmentation, revealing new details about the flavor and charge dependence of hadronization.

Matousek, Gregory [Duke Univ., Durham, NC (United ↗

Evolution of intermittent filaments in the scrape-off layer of NSTX

Filamentary structures naturally arise from background turbulence in the scrape-off layer (SOL) of plasmas, leading to significant particle and heat transport that can degrade overall plasma confinement. This enhanced transport can contribute to unacceptably high heat loads on plasma-facing components. As such, understanding the physics of SOL plasma filaments is critical for predicting and mitigating their effects in future fusion devices. On the National Spherical Torus Experiment (NSTX), plasma filaments—commonly referred to as “blobs”—were investigated using the gas-puff imaging (GPI) diagnostic in the edge and SOL regions. The analysis involved identifying, segmenting, and tracking the characteristic contours of the blobs in each frame of the GPI video sequences. Their evolution was characterized through shape descriptors, velocity, and angular velocity derived from their contour coordinates. The results indicate that as the blob area increases, their shapes become more concave and less circular, suggesting reduced structural stability in larger blobs. This result aligns with previous theoretical results where it was shown that larger blobs are more susceptible to instabilities [Krasheninnikov et al., J. Plasma Phys. 74, 679–717 (2008) and D'Ippolito et al., Phys. Plasmas 18, 060501 (2011)]. A positive correlation was observed between radial velocity and radial position, suggesting radially outward acceleration of the filaments, potentially driven by decreasing viscous drag toward the far SOL. Interestingly, blobs in background SOL turbulence exhibited minimal spinning in contrast to filaments originating from edge localized modes, which show substantial rotation during their paths [Lampert et al., Phys. Plasmas 29, 102502 (2022)]. Statistical analysis of the solidity and total curvature shape descriptors, along with their temporal evolution, revealed relatively broad, near-Gaussian distributions. This suggests that blob morphology is strongly influenced by stochastic turbulent processes in the surrounding plasma environment. Blob parameters were also compared with bulk plasma and radial profile measurements. Notable trends were found between blob rotation and poloidal velocity with collisionality and line-integrated density. These findings contribute to a deeper understanding of blob dynamics and provide valuable insights for refining SOL turbulence models.

Covariance and correlation↗

bicep2/KECK ARRAY. IV. OPTICAL CHARACTERIZATION AND PERFORMANCE OF THE bicep2 AND KECK ARRAY EXPERIMENTS

bicep2 and the Keck Array are polarization-sensitive microwave telescopes that observe the cosmic microwave background (CMB) from the South Pole at degree angular scales in search of a signature of inflation imprinted as B-mode polarization in the CMB. bicep2 was deployed in late 2009, observed for three years until the end of 2012 at 150 GHz with 512 antenna-coupled transition edge sensor bolometers, and has reported a detection of B-mode polarization on degree angular scales. The Keck Array was first deployed in late 2010 and will observe through 2016 with five receivers at several frequencies (95, 150, and 220 GHz). bicep2 and the Keck Array share a common optical design and employ the field-proven bicep1 strategy of using small-aperture, cold, on-axis refractive optics, providing excellent control of systematics while maintaining a large field of view. This design allows for full characterization of far-field optical performance using microwave sources on the ground. Here we describe the optical design of both instruments and report a full characterization of the optical performance and beams of bicep2 and the Keck Array at 150 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

A Novel Approach for Computing Rigid Body Motion Using Linear Accelerations

Here, a novel approach is presented for computing general rigid body motion based on a few known linear accelerations. This method utilizes linear acceleration data obtained from three distinct points on the body, all within a body-fixed reference frame. The only requirement is that the three chosen points must not be collinear. A system of differential-algebraic equations is derived, combining principles of rigid body kinematics with theory of the rotation group SO(3). These equations provide a framework for numerically computing various motion parameters, including angular velocity, angular acceleration, body orientation, velocity field, acceleration field, and displacement field. By numerically solving this system of equations, we can fully characterize rigid body motion in three-dimensional space. A numerical example is provided to demonstrate the practical implementation and efficacy of the proposed technique, illustrating its potential for accurate motion computation in various applications.

42 ENGINEERING↗

Emittance growth due to multiple passes through H-minus stripping foil in Booster

Expressions for transverse emittance growth due to turn-by-turn passes through the H-minus stripping foil in Booster are developed here from simple principles of statistics and simple assumptions about the initial distribution of particles incident on the foil. These are meant to complement work already presented by Zeno [1, 2, 3] and Brown [4]. The expressions show that while the average emittance hEi of the distribution simply increases linearly with turn number, the emittance E based on the mean square particle position does so with an additional oscillatory term that depends on the machine tune. It is shown that this term can be ignored as long as the turn number is su ciently large and the tune is su ciently far from integer and half-integer values. Under these conditions the relation between hEi and E is simply hEi = 2 E. This relation is shown to hold for a Gaussian distribution that is matched to the machine lattice. Two symmetry conditions which help characterize the particle distribution are identi ed. These provide justi cation for calling E an emittance. It is shown that if the conditions are satis ed by the initial distribution, they will not be satis ed after a single traversal of the foil and one turn around the machine. However, on subsequent turns the distribution can (and does) return to satisfying the conditions. Moreover, for su ciently large turn number, the symmetry conditions are approximately satis ed. As already noted in [4], the emittance growth per turn is proportional to the lattice beta at the foil and the mean square angular kick received by protons passing through the foil. We take the former to be 5 m. The latter is obtained from simulations performed with the code TRIM [5]. Having these numbers in hand, actual numbers for emittance growth are presented. The reader may wish to start with Section 11 and refer to previous sections as needed or desired.

43 PARTICLE ACCELERATORS↗