Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Air Liquide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Performance of 4600-pound-thrust centrifugal-flow-type turbojet engine with water-alcohol injection at inlet

An experimental investigation of the effects of injecting a water-alcohol mixture of 2:1 at the compressor inlet of a centrifugal-flow type turbojet engine was conducted in an altitude test chamber at static sea-level conditions and at an altitude of 20,000 feet with a flight Mach number of 0.78 with an engine operating at rated speed. The net thrust was augmented by 0.16 for both flight conditions with a ratio of injected liquid to air flow of 0.05. Further increases in the liquid-air ratio did not give comparable increases in thrust.

Glasser, Philip W↗

Ionic Liquids for Direct Air Capture of CO 2 using Electric‐Field‐Mediated Moisture Gradient Process (Final Technical Report)

The final report provides executive summary, a list of publications, and information on training graduate students and postdoctoral researchers. We carried out computational and experimental research on understanding molecular-level mechanism of how CO 2 is absorbed in a solution containing ethylene glycol as the solvent and KOH as the salt in the presence of ionic liquids and under the influence of electric field. In doing so, we developed an automated high-throughput method which allowed us to measure the solubility of CO 2 in a large number of ionic liquids, considerably speeding up the CO 2 solubility measurement. We also demonstrated how varying the concentration of ionic liquids in ethylene glycol can result in a maximum in ionic conductivity. Reaction of CO 2 and subsequent release results in a 50% reduction when the process is operated at an ionic liquid-ethylene glycol concentration yielding maximum ionic conductivity amongst all the ionic liquid-ethylene glycol combinations studied as a part of this research. We utilized machine learning models to identify unique ionic liquid-solvent combinations with ionic conductivity much higher than that measured for ionic liquid-ethylene glycol combinations. We demonstrated that the rate of CO 2 reaction with KOH in ethylene glycol can be optimized with the type of ionic liquid and its concentration. Overall, the research led to publication of 10 peer-reviewed research articles and several presentations at national conferences. We are also in the process of developing additional manuscripts based on the research carried out as a part of this project. Two graduate students and two postdoctoral researchers were supported on the funding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spray Characteristics of a Hybrid Twin-Fluid Pressure-Swirl Atomizer

The spray performance of a fuel injection system applicable for use in main combustion chamber of an oxidizer-rich staged combustion (ORSC) cycles is presented. The experimental data reported here include mean drop size and drop size distribution, spray cone half-angle, and momentum rate (directly related to spray penetration). The maximum entropy formalism, MEF, method to predict drop size distribution is applied and compared to the experimental data. Geometric variables considered include the radius of the injector inlet orifice plate through which oxidizer flows (&) and the exposed length from the fuel inlet to the injector exit plane (L2). Operating conditions that were varied include the liquid mass flow rate and air mass flow rate. For orifices B and C there is a significant dependence of D3Z on both the air and liquid mass flow rates, as well as on L2. For the A orifice, the momentum rate of the air flow appears to exceed a threshold value above which a constant D32 is obtained. Using the MEF method, a semi-analytical process was developed to model the spray distribution using two input parameters (q = 0.4 and Dso). The momentum rate of the spray is directly related to the air and liquid mass flow rates. The cone half angle of the spray ranges from 25 to 17 degrees. The data resulting from this project will eventually be used to develop advanced rocket systems.

Durham, M. J.↗

Turbulent mixing by microscopic self-assembled spinners

A system for mixing particles that includes a liquid comprising inert particles and defining a liquid and air interface; magnetic microparticles suspended at the liquid and air interface; and a magnetic source configured to apply a uniaxial alternating magnetic field parallel to the liquid and air interface, wherein the uniaxial alternating magnetic field promotes a turbulent motion of the magnetic microparticles, which in turn promotes a diffusive motion of the inert particles.

Snezhko, Oleksiy↗

Analytical description of the breakup of liquid jets in air

A viscous or inviscid cylindrical jet with surface tension in a vacuum tends to pinch due to the mechanism of capillary instability. Similarity solutions are constructed which describe this phenomenon as a critical time is encountered, for two physically distinct cases: inviscid jets governed by the Euler equations and highly viscous jets governed by the Stokes equations. In both cases the only assumption imposed is that at the time of pinching the jet shape has a radial length scale which is smaller than the axial length scale. For the inviscid case, we show that our solution corresponds exactly to one member of the one-parameter family of solutions obtained from slender jet theories and the shape of the jet is locally concave at breakup. For highly viscous jets our theory predicts local shapes which are monotonic increasing or decreasing indicating the formation of a mother drop connected to the jet by a thin fluid tube. This qualitative behavior is in complete agreement with both direct numerical simulations and experimental observations.

Papageorgiou, Demetrios T.↗

Air Dehumidification using Ionic Liquid-Based Fiber Bundle Membrane Contactor

Air dehumidification is essential since excess moisture in the buildings causes discomfort to the occupants, encourages the production of air pathogens such as mold or mildew, and causes corrosion and rotting that degrade building materials. Existing moisture removal processes are mainly focused on condensation and desiccant (liquid or solid) techniques with direct contact between air and desiccant. However, these methods are energy-intensive, or desiccant might be lost or cause corrosion in the process. The main objective of this study is to investigate an ionic liquid-based liquid desiccant absorber based on a membrane fiber bundle. The novel system consists of membrane contactors containing bundles of 10,000 polypropylene fibers. The fiber bundles have 0.3 micron diameter, with ionic liquid flowing inside, and air flowing outside. The fibers provide a high contact area among phases: 1.4 m2 contact surface area in a 0.00015 m3 volume. The ionic liquid as a sorbent stipulates the selectivity for air, prevents the loss of solvent in the operation due to negligible volatility, provides fast diffusion due to low viscosity compared to common ionic liquids, and has high affinity and solubility in water. The dehumidification capacity of the membrane technology was experimentally investigated. The experimental results show that the ionic-liquid based membrane system can effectively remove excess moisture from the air. The novel fiber bundle dehumidification system has a system volume of 0.00798 m3 (7.98 L) and active heat and mass transfer surface area of 8.4 m2. It achieved an average dehumidification of 320 ± 25 W with a volumetric air flowrate of 3.1 m3/min (108 ft3/min).

Turnaoglu, Tugba↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing Science-based fueling protocols for 250-bar hydrogen tanks onboard hydrogen ferries: Experiments and modeling

Combined modeling and experimental studies are reported of the fueling of a large (28 kg capacity) 250-bar Type IV hydrogen tank of the type being deployed on early hydrogen ferries, such as the MV Sea Change. The primary goal was to determine how such tanks can be successfully fueled with hydrogen (state of charge greater than 97%) within 45 minutes without exceeding the 82 °C temperature limit for such tanks. The modeling studies show that a gas injector is needed to avoid thermal stratification during hydrogen fueling which can result in potential hot spots. Empirically, precooling of the hydrogen to 0 °C was found to be needed in some of the cases examined, as ambient conditions greatly affected the need for a precooling to achieve the 45-minute fill time desired by end users. The experimental results afforded a calibration of the engineering model SOFIL for these large 250-bar tanks, which now enables using SOFIL to predict volume-averaged hydrogen fueling temperatures to an accuracy of ±2.7°C for these tanks. The model can therefore be used to evaluate potential scenarios for development of a standardized fueling methodology for ferries utilizing large Type-IV tanks.

08 HYDROGEN↗

Cooling Matters: Benchmarking Large Language Models and Vision-Language Models on Liquid-Cooled Versus Air-Cooled H100 GPU Systems

The unprecedented growth in artificial intelligence (AI) workloads, recently dominated by large language models (LLMs) and vision-language models (VLMs), has intensified power and cooling demands in data centers. This study benchmarks LLMs and VLMs on two HGX nodes, each with 8× NVIDIA H100 graphics processing units (GPUs), using liquid and air cooling. Leveraging GPU Burn, Weights & Biases, and IPMItool, we collect detailed thermal, power, and computation data. Results show that the liquid-cooled systems maintain GPU temperatures between 41-50$^\circ$C, while the air-cooled counterparts fluctuate between 54-72$^\circ$C under load. This thermal stability of liquid-cooled systems yields 17% higher performance (54 TFLOPs/ GPU vs. 46 TFLOPs/GPU), performance-per-watt, reduced energy overhead, and greater system efficiency than the air-cooled counterparts. These findings underscore the energy and sustainability benefits of liquid cooling, offering a compelling path forward for hyperscale data centers seeking to optimize AI infrastructure. https://github.com/iscaas/Cooling-Matters.

Latif, Imran↗

An exploratory study to determine the integrated technological air transportation system ground requirements of liquid-hydrogen-fueled subsonic, long-haul civil air transports

An exploratory study was conducted to evaluate the feasibility and cost impact of implementing a liquid-hydrogen-fueled (LHz), air transport support system at Chicago-O’Hare International Airport. The study assumed an available supply of hydrogen to the airport boundary. It also assumed that the present widebody fleet at O’Hare was replaced by 400 passenger, LH2-fueled aircraft operating on the current frequency schedule and route network. The LH2 aircraft configurations used in this study were developed during a previous NASA-sponsored study. A baseline air terminal concept was developed which permitted airlines and the airport to operate JP- or LH2-fueled aircraft at common terminal gates. The concept included installation of a hydrogen liquefaction and storage facility on airport property, as well as the fuel distribution system. The capital investment and hydrogen-related operating costs to the airlines were estimated. The study concluded that the system would be technically and operationally feasible at O’Hare, and that economics would be a prime factor in future decisions regarding the use of LH2 as an air transport fuel. Research and technology recommendations were made to improve component efficiency/reliability. The study also concluded that additional investigation should be conducted on the implementation of a nationwide or worldwide LH2 air transportation system, to understand fully the operational and economic implications of the total system, before decisions could be made relative to committing to this option.

Hydrogen↗

Climate Impact on CO2 Capture Efficiency and Levelized Cost of Liquid solvent-based DAC (Direct Air Capture) System

The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.

An, Keju↗

Multiple-orifice liquid injection into hypersonic air streams.

Review of oblique water and fluorocarbon injection test results obtained in experimental studies of the effects of multiple-orifice liquid injection into hypersonic air streams. The results include the finding that maximum lateral penetration from such injections increases linearly with the square root of the jet-to-freestream dynamic-pressure ratio and is proportional to an equivalent orifice diameter.

Weaver, W. L.↗

Solar system installation at Louisville, Kentucky

The installation of a solar space heating and domestic hot water system is described. The overall philosophy used was to install both a liquid and a hot air system retrofitted to existing office and combined warehouse building. The 1080 sq. ft. office space is heated first and excess heat is dumped into the warehouse. The two systems offer a unique opportunity to measure the performance and compare results of both air and liquid at one site.

Source record↗

Carbon Capture in Novel Porous Liquids

Direct air capture (DAC) of CO 2 is one of the negative emission technologies under development to limit the impacts of climate change. The dilute concentration of CO 2 in the atmosphere (~400 ppm) requires new materials for carbon capture with increased CO 2 selectivity that is not met with current materials. Porous liquids (PLs) are an emerging material that consist of a combination of solvents and porous hosts creating a liquid with permanent porosity. PLs have demonstrated excellent CO 2 selectivity, but the features that control how and why PLs selectively capture CO 2 is unknown. To elucidate these mechanisms, density functional theory (DFT) simulations were used to investigate two different PLs. The first is a ZIF-8 porous host in a water/glycol/2-methylimidazole solvent. The second is the CC13 porous organic cage with multiple bulky solvents. DFT simulations identified that in both systems, CO 2 preferentially bound in the pore window rather than in the internal pore space, identifying that the solvent-porous host interface controls the CO 2 selectivity. Additionally, SNL synthesized ZIF-8 based PL compositions. Evaluation of the long-term stability of the PL identified no change in the ZIF-8 crystallinity after multiple agitation cycles, identifying its potential for use in carbon capture systems. Through this project, SNL has developed a fundamental understanding of solvent-host interactions, as well as how and where CO 2 binds in PLs. Through these results, future efforts will focus not on how CO 2 behaves inside the pore, but on the porous host-solvent interface as the driving force for PL stability and CO 2 selectivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Liquid seeding atomizer

An atomizer for a liquid having an air supply is described. Liquid supply tubes extend longitudinally along the air supply tube. The air supply tube has at least one air orifice extending from an inner surface of the tube through the tube. The liquid supply tubes are positioned on either side of the air orifices and the liquid tubes are sealed to the air supply tube. The liquid supply tubes with facing liquid orifices are positioned adjacent to each of the air orifices. The liquid supply tubes are laterally spaced apart at the liquid orifices at a distance less than the diameter of the air orifices to enable a beneficial venturi effect when the atomizer is in operation.

Seegmiller, Henry L. B.↗

Wing-Nacelle-Propeller Tests - Comparative Tests of Liquid-Cooled and Air-Cooled Engine Nacelles

This report gives the results of measurements of the lift, drag, and propeller characteristics of several wing and nacelle combinations with a tractor propeller. The nacelles were so located that the propeller was about 31% of the wing chord directly ahead of the leading edge of the wing, a position which earlier tests (NASA Report No. 415) had shown to be efficient. The nacelles were scale models of an NACA cowled nacelle for a radial air-cooled engine, a circular nacelle with the V-type engine located inside and the radiator for the cooling liquid located inside and the radiator for the type, and a nacelle shape simulating the housing which would be used for an extension shaft if the engine were located entirely within the wing. The propeller used in all cases was a 4-foot model of Navy No. 4412 adjustable metal propeller. The results of the tests indicate that, at the angles of attack corresponding to high speeds of flight, there is no marked advantage of one type of nacelle over the others as far as low drag is concerned, since the drag added by any of the nacelles in the particular location ahead of the wing is very small. The completely cowled nacelle for a radial air-cooled engine appears to have the highest drag, the liquid-cooled engine appears to have the highest drag, the liquid-cooled engine nacelle with external radiator slightly less drag. The liquid-cooled engine nacelle with radiator in the cowling hood has about half the drag of the cowled radial air-cooled engine nacelle. The extension-shaft housing shows practically no increase in drag over that of the wing alone. A large part of the drag of the liquid-cooled engine nacelle appears to be due to the external radiator. The maximum propulsive efficiency for a given propeller pitch setting is about 2% higher for the liquid-cooled engine nacelle with the radiator in the cowling hood than that for the other cowling arrangements.

Wood, Donald H.↗