Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Passive Temperature Sensors for Nuclear Applications

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at material and test reactors. Passive temperature monitors, such as Silicon Carbide (SiC) and melt wires, may be included in such tests as an independent technique of detecting peak temperatures experienced during irradiation. In less expensive static (drop-in) capsule tests, which have no leads attached for real-time data transmission, melt wires, and SiC temperature monitors (TMs) are essentially the only possibility for peak temperature indication. A melt wire involves placing materials (wires) of a known composition and melting temperature in a test. An inventory is maintained at Material Science Laboratory (MSL) for melt wires ranging in temperatures from 30°C to 1500°C. Unfortunately, melt wires are limited in that it can only detect whether a single temperature is or is not exceeded (melt wire melted or not). SiC TMs, which can also be used to detect peak irradiation temperatures, are advantageous because a single monitor can allow to determine the peak temperature reached within a relatively broad range (100 – 1200°C) resulting in accuracies within ±20°C. Irradiation temperature is determined by measuring a property change after isochronal annealing or during a continuously monitored annealing process using specialized equipment at MSL. Recent research has produced a passive monitor known as sublime temperature monitor. This passive sensor has the capability of recording temperature gradients and pinpointing exactly where a temperature is located along that gradient. Long measurement lengths are achieved with very high accuracy in the location of desired temperature measurements (±2 mm over a 1 m span); however, this sensor has not been deployed in a nuclear reactor. This article will focus only on passive temperature sensors currently being researched and implemented under the Advanced Sensors and Instrumentation (ASI) program at Idaho National Laboratory (INL).

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The ARENA Test Bed – A Versatile Resource for I&C Development and Validation

The Accelerated and Real-time Experimental Nodal Assessment (ARENA) Test Bed at the Pacific Northwest National Laboratory (PNNL) is a versatile resource for development and validation of instrumentation and control (I&C) technologies. This capability was created to facilitate in-situ testing of nuclear electrical cables in various simulated operational environments. Using cable trays, a control box, and selected test components, low voltage cables can be staged to experience local adverse environments such as elevated temperature and water immersion. Cable condition can be continuously monitored over time to track the effect of local stresses using nondestructive assessment tools. A heads-up display (ARENA TV) plots key data in real-time for users. The ARENA Test Bed has recently been used to evaluate the potential for spread spectrum time domain reflectometry (SSTDR) to monitor thermal aging of a portion of live cable powering a three-phase motor. The arrangement provided the opportunity to directly compare the performance of the novel online SSTDR method with offline results from the more standard frequency domain reflectometry (FDR) method. The ability of SSTDR and FDR to identify the presence of water in immersed shielded and unshielded cables and to detect ground faults was also assessed. A digital twin is being developed to track and predict FDR signals from a thermally aging conceptual cable region to compare with measured signals from the ARENA physical counterpart. The test bed concept addresses an important need in nuclear I&C monitoring tool development. New tools and techniques can be developed in the test bed and validated versus known methods and physical measurements. Digital twins and machine learning engines can be populated with measured data in a controlled environment that would not be readily available in the actual nuclear power plant. Proposed monitoring strategies can be confirmed for effectiveness through objective evaluation. It is anticipated that the PNNL ARENA Test Bed will be a valuable resource in advancing nuclear plant instrumentation.

nuclear electrical cables, ARENA Test Bed, conditi↗

Addition of transient kinetics capabilities to an infrared reflection absorption spectroscopy system through synchronized gas pulsing and data acquisition

Surface science methodologies for understanding thermodynamic aspects of surface processes are at an advanced level. However, instrumentation and approaches for extracting kinetic parameters from elementary steps are far less accessible. In this work, we present an approach combining the use of a fast gas pulsing valve synchronized with data acquisition to enable surface transient kinetics studies using infrared reflection absorption spectroscopy. This methodology applies to the study of reversible processes and borrows concepts and ideas from molecular beam scattering and temporal analysis of products. Here, a temporal resolution of ~67 ms is achieved, and this is illustrated through the study of CO adsorption and desorption on a Pd(111) crystal in the presence and absence of background O 2 . The same approach can be extended to other surface spectroscopies, such as X-ray photoelectron spectroscopy, to obtain spectra with high temporal resolution and signal-to-noise ratio and enable future multimodal surface transient kinetic studies aiming at elucidating reaction mechanisms.

36 MATERIALS SCIENCE↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Autonomous closed-loop mechanistic investigation of molecular electrochemistry via automation

Abstract Electrochemical research often requires stringent combinations of experimental parameters that are demanding to manually locate. Recent advances in automated instrumentation and machine-learning algorithms unlock the possibility for accelerated studies of electrochemical fundamentals via high-throughput, online decision-making. Here we report an autonomous electrochemical platform that implements an adaptive, closed-loop workflow for mechanistic investigation of molecular electrochemistry. As a proof-of-concept, this platform autonomously identifies and investigates an EC mechanism, an interfacial electron transfer ( E step) followed by a solution reaction ( C step), for cobalt tetraphenylporphyrin exposed to a library of organohalide electrophiles. The generally applicable workflow accurately discerns the EC mechanism’s presence amid negative controls and outliers, adaptively designs desired experimental conditions, and quantitatively extracts kinetic information of the C step spanning over 7 orders of magnitude, from which mechanistic insights into oxidative addition pathways are gained. This work opens opportunities for autonomous mechanistic discoveries in self-driving electrochemistry laboratories without manual intervention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Properties of Nb x Ti (1–x) N thin films deposited on 300 mm silicon wafers for upscaling superconducting digital circuits

Scaling superconducting digital circuits requires fundamental changes in the current material set and fabrication process. The transition to 300 mm wafers and the implementation of advanced lithography are instrumental in facilitating mature CMOS processes, ensuring uniformity, and optimizing the yield. Here, this study explores the properties of Nb x Ti (1–x) N films fabricated by magnetron DC sputtering on 300 mm Si wafers. As a promising alternative to traditional Nb in device manufacturing, Nb x Ti (1–x) N offers numerous advantages, including enhanced stability and scalability to smaller dimensions, in both processing and design. As a ternary material, Nb x Ti (1–x) N allows engineering material parameters by changing deposition conditions. The engineered properties can be used to modulate device parameters through the stack and mitigate failure modes. We report characterization of Nb x Ti (1–x) N films at less than 2% thickness variability, 2.4% T c variability and 3% composition variability. Film resistivity (140–375 Ωcm) shows a strong correlation with the film oxygen content, while the critical temperature T c (4.6 K–14.1 K) is strongly affected by film stoichiometry and its microstructure has only a moderate effect on modifying T c . Our results offer insights about the interplay between film stoichiometry, film microstructure and critical temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

DOE Energy Frontier Research Centers Center for Direct Catalytic Conversion of Biomass to Biofuels (C3Bio)

New capabilities to predict, design and control the chemistries of carbon could answer a global imperative to transition from fossil-based to sustainable transportation fuels. While the use of inexpensive hydrocarbons has been an unparalleled achievement and enabler of economic prosperity for many nations, singular dependence upon crude oil has given rise to systemic vulnerabilities in climate, energy, economic, and national security. Lignocellulosic biomass, a renewable and carbon-neutral resource, has the potential to displace an estimated annual equivalent of three billion barrels of oil in the U.S. alone (National Research Council 2009, U. S. Department of Energy, 2011). However, biomass has only one-third the energy density of crude oil (Agrawal and Singh 2009, Richard 2010) and lacks petroleum’s versatility as a feedstock for fuels and chemicals. These limitations keep biomass conversion below the efficiency level needed for strategic impact while the scientific challenge of routing carbon from one molecular context to another remains unmet. In 2009, the Center for Direct Catalytic Conversion of Biomass to Biofuels (C3Bio) recognized the potential of chemical catalysis and fast pyrolysis to overcome such limitations by transforming the main components of biomass (cellulose, xylan, and lignin) from grasses and trees directly to liquid hydrocarbons and aromatic co-products. Enabled by the EFRC high-risk, high-reward approach to grand challenge science, C3Bio researchers have been key national players in disrupting the conventional paradigm of the cellulosic biorefinery into a new future of “no carbon left behind”—the full utilization of carbon from plant cell walls in energy-dense fuels (Fig. 1). We identified catalytic and fast-pyrolytic pathways that utilize cellulose, xylan and, most significantly, lignin. We developed catalytic processes that deoxygenate and transform monomers and isolated polymers into useful products and tested their use with intact biomass. We gained control of lignin synthesis within plants and initiated tailoring biomass to its end-use through the tools of plant molecular biology and genetic engineering. C3Bio breakthroughs have increased the energy density of biomass-derived substrates via catalytic and pyrolytic conversions into products such as benzoquinones, furfural and hydroxymethylfurfural, levoglucosan and levulinic acid, methoxypropylphenols and propylbenzene. Such advances in biomass conversion would not have been possible without simultaneous advances in analytical instrumentation and methodologies, and imaging technologies and applications. The legacy science developed by C3Bio enables design and control strategies for achieving a targeted product portfolio of fuel and chemical feedstocks from a diverse range of native and tailored biomass. Our research provides the knowledge base required for a bio-economy with product streams as diverse in functionality as those of the petrochemical industry. Coupling targeted computational modeling with experimentation, we achieved: (1) fundamental understanding of biopolymers and cell wall architecture assembly, (2) discovery of new chemistries that allow the development of highly selective pathways to fuels and desirable chemicals, and (3) an integrated systems-level understanding to control catalytic and pyrolytic pathways.

09 BIOMASS FUELS↗

Draft Methodology for Cybersecurity Analysis for Adoption of Wireless Technology in Nuclear Power Plants

The report is delivered as DOE-NE Cybersecurity Program Milestone M2CT-22IN1104014-Industry cybersecurity guidance adoption status. The milestone is specifically to document the process and the status of the efforts towards developing guidance in support of industry’s adoption of wireless communication technologies. To transform the operation of nuclear power plants, including domestic light-water reactors, advanced reactors, microreactors, and fission battery, for grid and non-grid applications, secure and resilient wireless capabilities are required. In addition, to realize new operational concepts such as autonomous operation and remote monitoring, advanced sensor, and instrumentation, wireless technology is essential. However, industry implementation is low, and there is no technical basis for how to understand and address potential risks for wireless communications for critical plant functions. A methodology with a technical basis for implementing secure wireless communication is crucial. This wireless adoption methodology is intended to assist a licensee in identifying an appropriate technological approach for securing wireless communications in nuclear power plant. However, this methodology does not provide guidance for addressing wireless design criteria or for addressing all the cybersecurity commitments in licensees’ cybersecurity plans (CSPs) including addressing security impact analysis that a licensee must perform before an update to a Critical Digital Asset (CDA). This methodology guides a licensee through a process of evaluating a proposed wireless implementation and drafting a plant change notification for an example use case. The example is a generic/nonproprietary version of the first test case of the methodology, which, if successfully implemented, is part of the consideration for protecting other functions’ use of wireless in a cybersecure manner.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

OPEN-Augmented Reality GUI for Bioenergy Crop Phenotyping and Precision Agriculture (Donald Danforth Plant Science Center Final Scientific Technical Report)

The project led by the Donald Danforth Plant Science Center, in collaboration with Arizona State University, George Washington University, and Saint Louis University, has made significant strides in advancing the phenotypic analysis of bioenergy crops through the development of an innovative AI processing pipeline. This initiative was primarily funded by ARPA-E, with additional cost-sharing provided by the participating institutions. The project successfully utilized a variety of sensors—3D scanners, thermal, RGB, and hyperspectral—to refine algorithms for data-driven trait signature identification and improve the classification and visualization of plant traits. The developed AI processing pipeline is capable of handling the complex, multidimensional data characteristic of dynamic agricultural environments. 1) Contributions to understanding: The research has advanced the field of plant phenomics by showcasing the synergistic use of various sensor data to enhance the precision of trait analysis in bioenergy crops. Through the integration of 3D scanners, thermal, RGB, and hyperspectral sensors, the project has developed robust data-driven trait signature algorithms and visualization techniques. These innovations have facilitated detailed monitoring and management of plant traits, providing vital insights into plant growth dynamics and stress responses. Further, the project has broadened our understanding of how machine learning can be effectively applied in multi-sensor environments to refine trait analysis. By leveraging diverse datasets, the research has not only improved the accuracy of phenotypic assessments but also established a versatile methodological framework that can be extended beyond agriculture to other fields requiring detailed phenotypic analysis. 2) Technical effectiveness and economic feasibility: The AI processing pipeline developed in this project demonstrated significant technical effectiveness, achieving high throughput analysis of extensive phenotypic data and meeting targeted accuracies. This system exemplified the capability of advanced machine learning technologies to efficiently manage and analyze large, complex datasets. Economically, the implementation of the project-developed pipelines may offer substantial cost savings across multiple sectors. It enhances data analysis processes and significantly reduces the need for manual data interpretation, thereby decreasing both the time and resources required. 3) Public benefit: The project has significantly broadened the scope of agricultural methodologies to enhance phenotypic analysis, with potential applications in various sectors beyond agriculture. Additionally, the initiative fostered an enriching educational and collaborative environment, significantly enhancing the technical skills of participants. It also made substantial contributions to the scientific community by providing open-access data sets and tools, encouraging ongoing research and development across various disciplines. Overall, the project not only met its scientific goals but also showcased the extensive utility of integrating advanced machine learning and sensor data analysis technologies. These advancements have proven instrumental in driving forward both theoretical research and practical applications, setting a strong foundation for future explorations and innovations in data-driven science.

60 APPLIED LIFE SCIENCES↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

M3AS-25IN1002073: Analysis of data from irradiation testing of printed strain gauges in prototypic nuclear environments

Advancement in additively manufactured strain gauges help address critical technology gaps to accurately monitor real-time materials behavior in reactor experiments. This is critical as it provides data to inform predictive models and simulations that enhance the development of reactors and fuel cycle systems. In this report, additively manufactured strain gauges are exposed to a neutron irradiation environment at the Ohio State University Research Reactor. This report goes over a 2-week campaign for neutron irradiating printed resistive strain gauges and capacitive strain gauges. These results complement the prior separate effects (i.e., mechanical strain, temperature, etc.) testing that were performed on these additive manufactured sensors and presented in prior milestone reports. These results also help progress our understanding of their usage in harsh environment applications. The outcome of developing advanced sensing and instrumentation capabilities plays an important role in increasing the safety, reliability, and energy efficiency of both next-generation and existing nuclear reactors.

36 - MATERIALS SCIENCE↗

Carrier-assisted One-pot Sample Preparation for Targeted Proteomics Analysis of Small Numbers of Human Cells

Protein analysis of small numbers of human cells is primarily achieved by targeted proteomics with antibody-based immunoassays, which have inherent limitations (e.g., low multiplex and unavailability of antibodies for new proteins). Mass spectrometry (MS)-based targeted proteomics has emerged as an alternative because it is antibody-free, high multiplex, and has high specificity and quantitation accuracy. Recent advances in MS instrumentation make MS-based targeted proteomics possible for multiplexed quantification of highly abundant proteins in single cells. However, there is a technical challenge for effective processing of single cells with minimal sample loss for MS analysis. To address this issue, we have recently developed a convenient protein carrier-assisted one-pot sample preparation coupled with liquid chromatography (LC) - selected reaction monitoring (SRM) termed cLC-SRM for targeted proteomics analysis of small numbers of human cells. This method capitalizes on using the combined excessive exogenous protein as a carrier and low-volume one-pot processing to greatly reduce surface adsorption losses as well as high-specificity LC-SRM to effectively address the increased dynamic concentration range due to the addition of exogeneous carrier protein. Its utility has been demonstrated by accurate quantification of most moderately abundant proteins in small numbers of cells (e.g., 10-100 cells) and highly abundant proteins in single cells. The easy-to-implement features and no need for specific devices make this method readily accessible to most proteomics laboratories. In this study, we have provided a detailed protocol for cLC-SRM analysis of small numbers of human cells including cell sorting, cell lysis and digestion, LC-SRM analysis, and data analysis. Further improvements in detection sensitivity and sample throughput are needed towards targeted single-cell proteomics analysis. We anticipate that cLC-SRM will be broadly applied to biomedical research and systems biology with the potential of facilitating precision medicine.

60 APPLIED LIFE SCIENCES↗

Shallow cumuli cover and its uncertainties from ground-based lidar–radar data and sky images

Cloud cover estimates of single-layer shallow cumuli obtained from narrow field-of-view (FOV) lidar–radar and wide-FOV total sky imager (TSI) data are compared over an extended period (2000–2017 summers) at the established United States Atmospheric Radiation Measurement mid-continental Southern Great Plains site. We quantify the impacts of two factors on hourly and sub-hourly cloud cover estimates: (1) instrument-dependent cloud detection and data merging criteria and (2) FOV configuration. Enhanced observations at this site combine the advantages of the ceilometer, micropulse lidar (MPL) and cloud radar in merged data products. Data collected by these three instruments are used to calculate narrow-FOV cloud fraction (CF) as a temporal fraction of cloudy returns within a given period. Sky images provided by TSI are used to calculate the wide-FOV fractional sky cover (FSC) as a fraction of cloudy pixels within a given image. To assess the impact of the first factor on CF obtained from the merged data products, we consider two additional subperiods (2000–2010 and 2011–2017 summers) that mark significant instrumentation and algorithmic advances in the cloud detection and data merging. We demonstrate that CF obtained from ceilometer data alone and FSC obtained from sky images provide the most similar and consistent cloud cover estimates; hourly bias and root-mean-square difference (RMSD) are within 0.04 and 0.12, respectively. However, CF from merged MPL–ceilometer data provides the largest estimates of the multiyear mean cloud cover, about 0.12 (35 %) and 0.08 (24 %) greater than FSC for the first and second subperiods, respectively. CF from merged ceilometer–MPL–radar data has the strongest subperiod dependence with a bias of 0.08 (24 %) compared to FSC for the first subperiod and shows no bias for the second subperiod. The strong period dependence of CF obtained from the combined ceilometer–MPL–radar data is likely results from a change in what sensors are relied on to detect clouds below 3 km. After 2011, the MPL stopped being used for cloud top height detection below 3 km, leaving the radar as the only sensor used in cloud top height retrievals. To quantify the FOV impact, a narrow-FOV FSC is derived from the TSI images. We demonstrate that FOV configuration does not modify the bias but impacts the RMSD (0.1 hourly, 0.15 sub-hourly). In particular, the FOV impact is significant for sub-hourly observations, where 41 % of narrow- and wide-FOV FSC differ by more than 0.1. A new “quick-look” tool is introduced to visualize impacts of these two factors through integration of CF and FSC data with novel TSI-based images of the spatial variability in cloud cover. The influence of cloud field organization, such cloud streets parallel to the wind direction, on narrow- and wide-FOV cloud cover estimates can be visually assessed.

54 ENVIRONMENTAL SCIENCES↗

Observational data from uncrewed systems over Southern Great Plains

Uncrewed Systems (UxS), including uncrewed aerial systems (UAS) and tethered balloon/kite systems (TBS), are significantly expanding observational capabilities in atmospheric science. Rapid adaptation of these platforms and the advancement of miniaturized instruments have resulted in an expanding number of data sets captured under various environmental conditions by the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility. In 2021, observational data collected using ARM UxS platforms, including seven TigerShark UAS flights and 133 tethered balloon system (TBS) flights, were archived by the ARM Data Center and made publicly available to the user community https://adc.arm.gov/discovery/#/results/s::sgp*U3 and https://adc.arm.gov/discovery/#/results/s::sgp*tbs. These data streams provide new perspectives on spatial variability of atmospheric and surface parameters, helping to address critical science questions in Earth system science research. This manuscript describes the DOE UAS/TBS datasets, including information on the acquisition, collection, and quality control processes, and highlights the potential scientific contributions using UAS and TBS platforms.

54 ENVIRONMENTAL SCIENCES↗

FastML Science Benchmarks: Accelerating Real-Time Scientific Edge Machine Learning

Applications of machine learning (ML) are growing by the day for many unique and challenging scientific applications. However, a crucial challenge facing these applications is their need for ultra low-latency and on-detector ML capabilities. Given the slowdown in Moore's law and Dennard scaling, coupled with the rapid advances in scientific instrumentation that is resulting in growing data rates, there is a need for ultra-fast ML at the extreme edge. Fast ML at the edge is essential for reducing and filtering scientific data in real-time to accelerate science experimentation and enable more profound insights. To accelerate real-time scientific edge ML hardware and software solutions, we need well-constrained benchmark tasks with enough specifications to be generically applicable and accessible. These benchmarks can guide the design of future edge ML hardware for scientific applications capable of meeting the nanosecond and microsecond level latency requirements. To this end, we present an initial set of scientific ML benchmarks, covering a variety of ML and embedded system techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Research Activities on LVDTs: Modeling and Simulation Development and Performance Characterization of Commercial LVDTs

FY-22 research focused on two major areas. The first area was modeling and simulation with linked testing that will advance the Linear Variable Differential Transformers (LVDT) technology for use by stakeholders requiring LVDTs in upcoming irradiation tests. The second area focused on testing LVDTs purchased from U.S. suppliers that were investigated in FY-21. These cross-cutting development activities will ensure stakeholders have the current state-of-the-art LVDT-based technologies for deployment in future irradiation tests. Two stand-alone reports are included in the appendixes. The purpose of this report is to provide a convenient body of work to access the reports and to evaluate the data and conclusions provided. Appendix A, “Testing of the RDP Translation Transducer,” contains a complete evaluation of an RDP Electrosense linear transducer that has the capability of replicating the form, fit, and function of LVDTs currently being used at Idaho National Laboratory (INL). Appendix B is an extract from the report, “Advanced Sensors and Instrumentation Program at Boise State University (BSU), August 2022, Linear Variable Differential Transformers.” This report contains modeling and testing results conducted at BSU and INL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Temperature Irradiation Resistant Thermocouple Drift Model Application to Commercial Thermocouples

The Advance Sensors and Instrumentation fiscal year report on the direct application of the HTIR-TC drift model on other commercial thermocouples. The Type N and K thermocouples are useful in irradiation environments up to 1100°C (or 1290°C for short bursts and/or single use), but over temperature and high fluence can cause the TCs to drift. The HTIR-TC drift model predicts the end use environment of temperature and irradiation and the total time scale to show the amount of drift a thermocouple will undergo. The model predicts that HTIR-TCs at full temperature range and fluence of 10^21 N/cm^2 will exhibit a drift of under -1%. The type N and K TCs will see a drift of -0.5% at the same fluence, but temperatures below 1100°C. Above this temperature the Type N and K TCs quickly de-calibrate and will give erroneous temperatures measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗