Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Active Mirrors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Segmented mirror figure control for a space-based far-IR astronomical telescope

For segmented large mirrors to be used effectively for astronomy they must be actively aligned and controlled to extreme levels of precision. We consider the figure control problem for a spaceborne far-IR telescope, the Precision Segmented Reflector Project Focus Moderate Mission Telescope. We propose a two-stage approach. A figure initialization controller is used to achieve initial phasing and alignment of the telescope using an imaging science detector. A figure maintenance controller keeps the telescope aligned during normal operation using a laser metrology optical truss sensor system. We show that performance of any figure control system is subject to limits on the controllability of the wavefront. Maintenance controllers are additionally limited by considerations of the observability of the wavefront from the maintenance sensors. We show preliminary results for the figure initialization controller. We present a 'Wavefront Compensation' method for figure maintenance control that minimizes wavefront errors due to misalignment errors.

Redding, David↗

The Roman Space Telescope Coronagraph Technology Demonstration: Current Status and Relevance to Future Missions

The Nancy Grace Roman Space Telescope (formally WFIRST) will be launched in the mid-2020’s with an onboard coronagraph instrument which will serve as a technology demonstrator for exoplanet direct imaging. The Roman Coronagraph will be capable of detecting and characterizing exoplanets and circumstellar disks in visible light at an unprecedented contrast level of ~10-8 or lower. Such a contrast level, which is several magnitudes better than state-of-the-art visible or near-infrared coronagraphs, raises entirely new challenges that will be overcome using a combination of hardware, calibration and data processing. In particular, the Roman Coronagraph will be the first space-based coronagraphic instrument with real-time active wavefront control through the use of large format deformable mirrors, and its EMCCD detector will enable faint signal detection in photon-counting mode. The Roman Coronagraph passed its critical design review successfully in April 2021, and is now well on its path to demonstrate many core technologies at the levels required for future exo-Earth direct imaging missions.

Luchik, T.↗

Virtual Environment Platform for OT/IT Training Enhancement

TRADITIONAL TECHNIQUES OT/IT Concepts Operational Technology (OT) and Information Technology (IT) concepts can often be difficult to visualize Teaching Methods Traditional teaching methods lack the intuitive & immersive aspects of hands-on activities Caveat: Unless taught by Team B! Physical Limitations Digital Twins require existing systems/hardware to mirror UPDATED TECHNIQUES Virtual Environment By making use of a virtual environment, we can represent abstract concepts in a more approachable and digestible way Increased Engagement Students are more engaged with the activities and are more likely to retain the information they are given. New/Emerging Technologies As the system is currently growing and developing, the technologies in use, as well as those represented by the system, stay up-to-date.

Deroller, Nicholas F.↗

A Short-Range Distance Sensor with Exceptional Linearity

A sensor has been demonstrated that can measure distance over a total range of about 300 microns to an accuracy of about 0.1 nm (resolution of about 0.01 nm). This represents an exceptionally large dynamic range of operation - over 1,000,000. The sensor is optical in nature, and requires the attachment of a mirror to the object whose distance is being measured. This work resulted from actively developing a white light interferometric system to be used to measure the depths of defects in the Space Shuttle Orbiter windows. The concept was then applied to measuring distance. The concept later expanded to include spectrometer calibration. In summary, broadband (i.e., white) light is launched into a Michelson interferometer, one mirror of which is fixed and one of which is attached to the object whose distance is to be measured. The light emerging from the interferometer has traveled one of two distances: either the distance to the fixed mirror and back, or the distance to the moving mirror and back. These two light beams mix and produce an interference pattern where some wavelengths interfere constructively and some destructively. Sending this light into a spectrometer allows this interference pattern to be analyzed, yielding the net distance difference between the two paths. The unique feature of this distance sensor is its ability to measure accurately distance over a dynamic range of more than one million, the ratio of its range (about 300 microns) to its accuracy (about 0.1 nanometer). Such a large linear operating range is rare and arises here because both amplitude and phase-matching algorithms contribute to the performance. The sensor is limited by the need to attach a mirror of some kind to the object being tracked, and by the fairly small total range, but the exceptional dynamic range should make it of interest.

Simmons, Steven↗

Telescope Scientist on the Advanced X-Ray Astrophysics Observatory

The most important activity during this reporting period was the calibration of the AXAF High Resolution Mirror Assembly (HRMA) and the analysis of the copious data which were obtained during that project. The calibration was highly successful, and will result in the AXAF being by far the best calibrated X-ray observatory ever flown, and more accurate results by all of its users. This period also included participation in the spacecraft alignment and assembly activities and final flight readiness reviews. The planning of the first year of Telescope Scientist AXAF observations also was accomplished. The Telescope Scientist team also served as a technical resource for various problems which were encountered during this period. Many of these contributions have been documented in memoranda sent to the project.

VanSpeybroeck, Leon↗

Fabrication and Testing of a Large Active Primary Reflector

This paper discusses the fabrication considerations and proposed testing concepts for a twelve meter, graphite-epoxy space truss that is being developed to provide structural support for the primary mirror system of the SpacE Laser ENErgy Beam Transmission Optical System.

primary mirror↗

Investigations into mirror fabrication metrology analysis

This final report describes the work performed under this delivery order from June 1993 through August 1994. The scope of work included three distinct tasks in support of the AXAF-I program. The objective of the first task was to perform investigations of the grinding and polishing characteristics of the zerodur material by fabricating several samples. The second task was to continue the development of the integrated optical performance modeling software for AXAF-I. The purpose of third and final task was to develop and update the database of AXAF technical documents for an easy and rapid access. The MSFC optical and metrology shops were relocated from the B-wing of Building 4487 to Room BC 144 of Building 4466 in the beginning of this contract. This included dismantling, packing, and moving the equipment from its old location, and then reassembling it at the new location. A total of 65 zerodur samples, measuring 1 inch x 2 inches x 6 inches were ground and polished to a surface figure of lambda/10 p-v, and a surface finish of 5A rms were fabricated for coating tests. A number of special purpose tools and metal mirrors were also fabricated to support various AXAF-I development activities. In the metrology area, the ZYGO Mark 4 interferometer was relocated and also upgraded with a faster and more powerful processor. Surface metrology work was also performed on the coating samples and other optics using ZYGO interferometer and WYKO profilometer. A number of new features have been added to the GRAZTRACE program to enhance its analysis and modeling capabilities. A number of new commands have been added to the command mode GRAZTRACE program to provide a better control to the user on the program execution and data manipulation. Some commands and parameter entries have been reorganized for a uniform format. The command mode version of the convolution program CONVOLVE has been developed. An on-line help system and a user's manual have also been developed for the benefit of the users. The database of AXAF technical documents continues to progress. The titles, company name, date, and location of over 390 documents have been entered in this database. This database provides both a data search and retrieval function, and a data adding function. These functions allow a user to quickly search the data files for documents or add new information. A detailed user's guide has also been prepared. This user guide includes a document classification guide, a list of abbreviations, and a list of acronyms, which have been used in compiling this database of AXAF-I technical documents.

Dimmock, John O.↗

Calibration Results for the AXAF Flux Contamination Monitor

The Flux Contamination Monitor (FCM) on the Advanced X-ray Astrophysics Facility (AXAF) serves the purposes of transfering the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center to operation on orbit and of detecting any changes in molecular contamination of the High Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation phase. we describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and the subsequent analysis.

Elsner, Ronald F.↗

Calibration Results for the AXAF Flux Contamination Monitor

The AXAF Flux Contamination Monitor (FCM) serves the purposes of transferring the absolute flux calibration from the ground calibration at the X-Ray Calibration Facility (XRCF) to operation on orbit and of detecting any changes in molecular contamination of the High-Resolution Mirror Assembly (HRMA) between ground calibration and the post-launch activation. We describe the design, construction, and characterization of the FCM radioactive sources, and their placement on the Forward Contamination Cover (FCC). We present results from FCM measurements with the AXAF focal-plane instruments, particularly the AXAF CCD Imaging Spectrometer (ACIS), during the ground calibration phase at the XRCF in 1997. Finally, we describe the plans for FCM on-orbit measurements during observatory activation and for the subsequent analysis.

Elsner, R. F.↗

Active optics for space astronomy.

Discussion of the segmented and deformable active optics approaches underlying some of the modern electrooptical techniques that are to be used in the design of future generations of giant-aperture orbital space telescopes. Combinations of laser interferometry and precise servomechanisms are shown to make possible the solution of such key problems of large monolithic mirrors in orbit as weight, thermal distortion, launchability, and material stability. The applicability of these active optics approaches to future giant-aperture space astronomy systems in the 200-inch to 400-inch diameter range is reviewed.

Wischnia, H. F.↗

Oscillatory patterns in sympathetic neural discharge and cardiovascular variables during orthostatic stimulus

BACKGROUND: We tested the hypothesis that a common oscillatory pattern might characterize the rhythmic discharge of muscle sympathetic nerve activity (MSNA) and the spontaneous variability of heart rate and systolic arterial pressure (SAP) during a physiological increase of sympathetic activity induced by the head-up tilt maneuver. METHODS AND RESULTS: Ten healthy subjects underwent continuous recordings of ECG, intra-arterial pressure, respiratory activity, central venous pressure, and MSNA, both in the recumbent position and during 75 degrees head-up tilt. Venous samplings for catecholamine assessment were obtained at rest and during the fifth minute of tilt. Spectrum and cross-spectrum analyses of R-R interval, SAP, and MSNA variabilities and of respiratory activity provided the low (LF, 0.1 Hz) and high frequency (HF, 0.27 Hz) rhythmic components of each signal and assessed their linear relationships. Compared with the recumbent position, tilt reduced central venous pressure, but blood pressure was unchanged. Heart rate, MSNA, and plasma epinephrine and norepinephrine levels increased, suggesting a marked enhancement of overall sympathetic activity. During tilt, LF(MSNA) increased compared with the level in the supine position; this mirrored similar changes observed in the LF components of R-R interval and SAP variabilities. The increase of LF(MSNA) was proportional to the amount of the sympathetic discharge. The coupling between LF components of MSNA and R-R interval and SAP variabilities was enhanced during tilt compared with rest. CONCLUSIONS: During the sympathetic activation induced by tilt, a similar oscillatory pattern based on an increased LF rhythmicity characterized the spontaneous variability of neural sympathetic discharge, R-R interval, and arterial pressure.

NASA Program Biomedical Research and Countermeasur↗

Wavefront Analysis of Adaptive Telescope

The motivation for this work came from a NASA Headquarters interest in investigating design concepts for a large space telescope employing active optics technology. Current and foreseeable launch vehicles will be limited to carrying around 4-5 meter diameter objects. Thus, if a large, filled-aperture telescope (6-20 meters in diameter) is to be placed in space, it will be required to have a deployable primary mirror. Such a mirror may be an inflatable membrane or a segmented mirror consisting of many smaller pieces. In any case, it is expected that the deployed primary will not be of sufficient quality to achieve diffraction-limited performance for its aperture size. Thus, an active optics system will be needed to correct for initial as well as environmentally-produced primary figure errors. Marshall Space Flight Center has developed considerable expertise in the area of active optics with the PAMELA test-bed. The combination of this experience along with the Marshall optical shop's work in mirror fabrication made MSFC the logical choice to lead NASA's effort to develop active optics technology for large, space-based, astronomical telescopes. Furthermore, UAH's support of MSFC in the areas of optical design, fabrication, and testing of space-based optical systems placed us in a key position to play a major role in the development of this future-generation telescope. A careful study of the active optics components had to be carried out in order to determine control segment size, segment quality, and segment controllability required to achieve diffraction-limited resolution with a given primary mirror. With this in mind, UAH undertook the following effort to provide NASA/MSFC with optical design and analysis support for the large telescope study. All of the work performed under this contract has already been reported, as a team member with MSFC, to NASA Headquarters in a series of presentations given between May and December of 1995. As specified on the delivery order, this report simply summarizes the material with the various UAH-written presentation packages attached as appendices.

Hadaway, James B.↗

Application of the portable diagnostic package to the Wisconsin high-temperature-superconducting axisymmetric mirror (WHAM)

We present an application of the Portable Diagnostic Package (PDP) on the Wisconsin High-temperature-superconducting Axisymmetric Mirror (WHAM), which integrates an optical emission spectroscopy (OES) system and an active Thomson scattering (TS) system. The OES system facilitates a comprehensive impurity line survey and enables flow measurements through the Doppler effect observed on impurity lines. Plasma rotation profiles were successfully derived from doubly charged carbon lines. The TS system enabled the first measurements of the electron temperature in commissioning plasmas on WHAM. Notably, the PDP was installed, commissioned, and used to obtain OES and TS data within ∼6 months from project start, enabled by its designed portability and standardized interfaces. These results demonstrate the PDP’s potential to accelerate diagnostic readiness and advance experimental plasma studies.

Doppler effect↗

Amplitude and polarization asymmetries in a ring laser

Asymmetric amplitude effects between the oppositely directed traveling waves in a He-Ne ring laser are analyzed both theoretically and experimentally. These effects make it possible to detect angular orientations of an inner-cavity bar with respect to the plane of the ring cavity. The amplitude asymmetries occur when a birefringent bar is placed in the three-mirror ring cavity, and an axial magnetic field is applied to the active medium. A simplified theoretical analysis is performed by using a first order perturbation theory to derive an expression for the polarization of the active medium, and a set of self-consistent equations are derived to predict threshold conditions. Polarization asymmetries between the oppositely directed waves are also predicted. Amplitude asymmetries similar in nature to those predicted at threshold occur when the laser is operating in 12-15 free-running modes, and polarization asymmetry occurs simultaneously.

Campbell, L. L.↗

ExoSpec Project: An Exoplanet Spectroscopy Technology Research Collaboration Based at NASA’s Goddard Space Flight Center and Ames Research Center

The exoplanet atmosphere characterization goals of future UV/Optical/Infrared flagship space missions will drive challenging design requirements for instrument wavefront controls, spatial and spectral sampling, spectral bandwidth, and detector performance. The new ExoSpec Project links four previously distinct research efforts at Goddard and Ames for enabling and enhancing the characterization of directly-imaged exoplanets. ExoSpec is comprised of three laboratory subsystem demonstrations: high-contrast integral field spectrographs, p-channel CCDs, and parabolic deformable mirrors. A fourth component, exoplanet spectral retrieval, is an iterative data simulation activity driven by the goal of optimizing the system-level instrument design for atmosphere retrieval metrics. The ExoSpec Project’s emphasis on system-level spectroscopy performance complements the objectives of other technology demonstrations supported by NASA.

Neil T Zimmerman↗

Two-stage optics - High-acuity performance from low-acuity optical systems

The concept of two-stage optics, developed under a program to enhance the performance, lower the cost, and increase the reliability of the 20-m Large Deployable Telescope, is examined. The concept permits the large primary mirror to remain as deployed or as space-assembled, with phasing and subsequent control of the system done by a small fully assembled optical active element placed at an exit pupil. The technique is being applied to correction of the fabrication/testing error in the Hubble Space Telescope primary mirror. The advantages offered by this concept for very large space telescopes are discussed.

Meinel, Aden B.↗

X-ray photographs of a solar active region with a multilayer telescope at normal incidence

An astronomical photograph was obtained with a multilayer X-ray telescope. A 4-cm tungsten-carbon multilayer mirror was flown as part of an experimental solar rocket payload, and successful images were taken of the sun at normal incidence at a wavelength of 44 A. Coronal Si XII emission from an active region was recorded on film; as expected, the structure is very similar to that observed at O VIII wavelengths by the Solar Maximum Mission flat-crystal spectrometer at the same time. The small, simple optical system used in this experiment appears to have achieved a resolution of 5 to 10 arcsec.

Underwood, J. H.↗

Tetravalent chromium (Cr(4+)) as laser-active ion for tunable solid-state lasers

Major accomplishments under NASA grant NAG-1-1346 are summarized. (1) numerical modeling of the four mirror astigmatically compensated, Z-fold cavity was performed and several design parameters to be used for the construction of a femtosecond forsterite laser were revealed by simulation. (2) femtosecond pulses from a continuous wave mode-locked chromium doped forsterite laser were generated. The forsterite laser was actively mode-locked using an acousto-optic modulator operating at 78 MHz with two Brewster high dispersion glass prisms for intra-cavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(sub 00) mode with 85 mW of continuous power tunable over 1230-1280 nm. The shortest pulses of 60-fs pulsewidth were measured. (3) Self-mode-locked operation of the Cr:forsterite laser was achieved. Synchronous pumping was used to mode lock the forsterite laser resulting in picosecond pulses, which in turn provided the starting mechanism for self-mode-locking. The pulses generated had an FWHM of 105 fs and were tunable between 1230-1270 nm. (4) Numerical calculations indicated that the pair of SF 14 prisms used in the cavity compensated for quadratic phase but introduced a large cubic phase term. Further calculations of other optical glasses indicated that a pair of SFN 64 prisms can introduce the same amount of quadratic phase as SF 14 prisms but introduce a smaller cubic phase. When the SF 14 prisms were replaced by SFN 64 prisms the pulsewidth was reduced to 50 fs. Great improvement was observed in the stability of the self mode-locked forsterite laser and in the ease of achieving mode locking. Using the same experimental arrangement and a new forsterite crystal with improved FOM the pulse width was reduced to 36 fs.

Seas, A.↗