Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

In this work, we examine the use of high-order tensor decompositions to analyze degradation pathways emerging from accelerated stress testing of silicon photovoltaic (PV) modules. Matrix-based decompositions are powerful tools for studying two-dimensional data arrays and form the foundation of a host of classical data analysis techniques. Tensors are high-order extrapolations of matrices that are able to account for more parameter dimensions, and a variety of tensor decomposition methods have been developed that similarly seek to extend insights from matrix decompositions to higher dimensions. Applying and interpreting tensor decomposition methods to sequences of PV module image data, we seek to uncover and isolate different degradation modes occurring from accelerated stress testing procedures. Further, we consider the contributions of different modes to PV module performance degradations.

data analysis↗

Towards validation of combined-accelerated stress testing through failure analysis of polyamide-based photovoltaic backsheets

Abstract Novel methods for advancing reliability testing of photovoltaic (PV) modules and materials have recently been developed. Combined-accelerated stress testing (C-AST) is one such method which has demonstrated reliable reproduction of some field-failures which were not reproducible by standard certification tests. To increase confidence and assist in the development of C-AST, and other new testing protocols, it is important to validate that the failure modes observed and mechanisms induced are representative of those observed in the field, and not the product of unrealistic stress conditions. Here we outline a method using appropriate materials characterization and modelling to validate the failure mechanisms induced in C-AST such that we can increase confidence in the test protocol. The method is demonstrated by applying it to a known cracking failure of a specific polyamide (PA)-based backsheet material. We found that the failure of the PA-based backsheet was a result of a combination of stress factors. Photo-oxidation from ultra-violet (UV) radiation exposure caused a reduction in fracture toughness, which ultimately lead to the cracking failure. We show that the chemical and structural changes observed in the backsheet following C-AST aging were also observed in field-aged samples. These results increase confidence that the conditions applied in C-AST are representative of the field and demonstrates our approach to validating the failure mechanisms induced.

14 SOLAR ENERGY↗

Dynamic Scaling Analysis of Accelerated Irradiation Testing on Additive Manufacturing Materials by Positron Annihilation

The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.

accelerated irradiation testing↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

Electrochemical characterization of evolving ionomer/electrocatalyst interactions throughout accelerated stress tests

Here, the degradation of polymer electrolyte membrane fuel cells (PEMFCs) catalyst layers used for heavy-duty vehicles was examined using a catalyst-specific accelerated stress test (AST). High surface area carbon supported dispersed Pt (Pt/HSC), annealed Pt (a-Pt/HSC) and PtCo (PtCo/HSC) alloy catalysts were examined over the course of 90,000 cycles by measuring changes in mass activity, O 2 transport resistance, electrochemical active surface area (ECSA), catalyst accessibility and ionomer-electrocatalyst interactions. Compared to a-Pt/HSC and Pt/HSC catalyst, the PtCo/HSC showed better initial mass activity, a larger initial mass transport loss, and faster degradation after the first 30k AST cycles, as a large portion of Co leached out during potential cycling. Pt/HSC showed higher initial performance relative to a-Pt/HSC but had faster degradation. STEM characterizations show that the ECSA losses are largely related to Pt dissolution resulting in either catalyst particle growth via the Ostwald ripening mechanism or redeposition in the membrane. Catalyst accessibility measurements showed decreased RH sensitivity for all three samples, while CO impedance measurements revealed a decrease in both Pt-water and carbon-water interactions. This implies that, Pt is either preferentially redepositing on the exterior of the carbon support, or that the ionomer is undergoing morphological changes enabling the enhanced intrusion of mesopores.

25 ENERGY STORAGE↗

Accelerated life tests of specimen heat pipe from Communication Technology Satellite (CTS) project

A gas-loaded variable conductance heat pipe of stainless steel with methanol working fluid identical to one now on the CTS satellite was life tested in the laboratory at accelerated conditions for 14 200 hours, equivalent to about 70 000 hours at flight conditions. The noncondensible gas inventory increased about 20 percent over the original charge. The observed gas increase is estimated to increase operating temperature by about 2.2 C, insufficient to harm the electronic gear cooled by the heat pipes in the satellite. Tests of maximum heat input against evaporator elevation agree well with the manufacturer's predictions.

Tower, L. K.↗

Results from Accelerated Environmental Testing of Barcoded Identifiers for UF 6 Cylinders

This report provides the qualitative and quantitative results from the accelerated environmental testing campaign. A total of 444 samples were subjected to 10 tests that included UV, salt fog, temperature, blowing dust, high pressure and temperature water, and impact exposure. Each sample included a two-dimensional barcode and an alphanumeric string representing the cylinder identification number. When evaluating the results, primary attention was placed on the decodability of the barcodes using a barcode verifier device, since machine scanning a barcode offers the greatest efficiency and accuracy gains when reading cylinder identification numbers during safeguards activities. Contrast was considered the critical test parameter because maintaining contrast under a wide range of environmental conditions is of fundamental importance to decoding the identification number of the barcodes. Additionally, manual readability of the alphanumeric string was considered an important factor in determining whether an inspector or operator could still read the identification number of the cylinder if the barcode proved to be undecodable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Accelerated Stress Testing Data for Silicon Photovoltaics Using Tensor Decomposition Methods

The photovoltaic (PV) industry is simultaneously targeting long warranties and new materials/designs for high-energy-yield modules, requiring an advanced methodology to forecast long-term durability of products with un-proven materials combinations. Extended, sequential, and combined stress testing methods are gaining popularity for assessing durability of PV modules/materials beyond the early-stage mortalities. Importantly, multiple degradation mechanisms can proceed simultaneously, and their separate contributions to the overall power loss should ideally be quantified. This work examines the use of data-driven tools towards developing a strategy for faster learning cycles in accelerated stress testing.

accelerated stress testing↗

Durability evaluation of a Fe–N–C catalyst in polymer electrolyte fuel cell environment via accelerated stress tests

In this work, an “atomically-dispersed” iron-nitrogen-carbon (Fe–N–C) catalyst was used to provide a systematic comparison of platinum group metal (PGM)-free electrocatalyst degradation as a function of accelerated stress tests (ASTs) in an acidic polymer electrolyte fuel cell (PEFC). It was determined that the majority of catalyst degradation was caused by cell operation in presence of O 2 . In contrast, potential cycling of the Fe–N–C-containing cathode under inert atmosphere over typical PEFC cathode operation from 0.95 to 0.6 V had little to no effect. The increase in kinetic overpotential is shown to be the major source of the PEFC performance decrease during the ASTs. These results continue to showcase the need for development of robust PGM-free electrocatalysts in concert with improved electrochemical performance.

25 ENERGY STORAGE↗

Evaluation of bifacial module technologies with combined–accelerated stress testing

In view of the increasing interest and market share of bifacial cells and modules, suitable substrates such as glass and transparent backsheets along with ethylene vinyl acetate (EVA) and polyolefin elastomer (POE) encapsulants were examined in combined-accelerated stress testing (C-AST) to evaluate and compare degradation modes. Testing with both monofacial and bifacial cells, we found glass-glass modules with monofacial cells led to greater grid finger breakage than those with polymeric backsheets. Furthermore, this is attributed to previous X-ray topography and modeling work showing higher stress in cells and interconnections in glass-glass modules than glass-backsheet modules. Consistent with the objectives of C-AST, which stresses modules at levels corresponding to the limits seen in the natural environment, we observed the UV-fluorescence signatures of modules tested in C-AST (considering the degradation associated with developing chromophores, moisture penetration and photobleaching effects) to be like those in fielded modules, more so than other chamber stress testing implemented for comparison. We found light-induced degradation (LID) in module types with regenerated (inactive) cells with C-AST, suggesting the possibility of LID destabilization in some field conditions. We could also distinguish potential-induced degradation (PID) on the back of the bifacial passivated emitter and rear cells (PERC) in C-AST. Confirming with ex-situ tests, we found polarization-type PID most prevalent in glass-glass modules with EVA as would be anticipated considering the greater leakage current through such module encapsulation. Unlike PID tests performed in the dark, which can lead to false positive PID test results, field-representative illumination is experienced by the modules on the front and back side while –1200 V system voltage is applied in C-AST, supporting the conclusion that this module type with glass-glass construction would be susceptible to PID in the field.

14 SOLAR ENERGY↗

FY2022 Status Report: Cold Spray for Canister SCC Mitigation and Repair

This progress report describes work performed during FY22 at Sandia National Laboratories (SNL) to assess the corrosion performance of cold spray coatings to enable optimization of cold spray for the purposes of mitigation and/or repair of potentially susceptible regions, corrosion, or stress corrosion cracking (SCC) in austenitic stainless steel for spent nuclear fuel (SNF) storage. Of particular concern is SCC, by which a through-wall crack could potentially form in a canister outer wall over time intervals that may be shorter than possible dry storage times. In FY21, initial corrosion explorations of cold spray coating were evaluated and in FY22, an expanded set of cold spray coatings with in-depth analysis of post-exposure accelerated testing was explored. Additionally, relevant atmospheric exposure testing was carried out and initial results are presented herein. The corrosion attack from the accelerated testing and more realistic atmospheric exposures environments were compared to identify potentially deleterious factors for corrosion as well as help to understand the applicability of accelerated testing for cold spray optimization. This initial analysis will help to enable optimization of the corrosion resistance cold spray, one of the more promising coating and repair techniques, for potential application in an SNF environment. Learnings from both are summarized, and implications and future work are presented in this report.

36 MATERIALS SCIENCE↗

Computational Modeling of Photovoltaic Mini-Modules Undergoing Accelerated Stress Testing

A finite element model of a four-cell photovoltaic mini-module was developed and compared to experimental results from an accelerated stress test protocol in order to validate that computational models can accurately represent their physical counterparts when subjected to mechanical loading and to assess mini-module representativeness against full scale photovoltaic modules. Deflected shapes across the simulated mini-modules were compared to measured mini-module shapes when subjected to various pressure loads. Displaced mini-module shape results constrained to the experimental protocols of 0.4 mm and 1.1 mm of displacement at the mini-module center were compared to experimental results of full-size modules subjected to module qualification test load levels of 1.0 kPa and 2.4 kPa, to assess if the bending of mini-modules was representative of full-sized modules under the load. Temperature cycling was incorporated into the model to simulate the impacts of stress due to thermal expansion of the backsheet and cells. A preliminary uncertainty analysis was performed to show how variations in material properties and geometric parameters change the simulation results.

computational modeling↗

Accelerated life testing and reliability of high K multilayer ceramic capacitors

The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

Minford, W. J.↗

Examining Light-Induced Degradation with Combined-Accelerated Stress Testing

While further understanding is sought, the results suggest that a module can show no degradation in performance through a qualification test light soak, (IEC 61215: 2021 MQT 19.1 requirement of 10 kW minimum on one side). Yet, such cells may degrade significantly by LID under conditions within the statistical extremes of the natural environment applied in combined-accelerated stress testing (CAST).

combined-accelerated stress testing↗

Failure Engineering Study and Accelerated Stress Test Results for the Mars Global Surveyor Spacecraft's Power Shunt Assemblies

An Engineering-of-Failure approach to designing and executing an accelerated product qualification test was performed to support a risk assessment of a "work-around" necessitated by an on-orbit failure of another piece of hardware on the Mars Global Surveyor spacecraft. The proposed work-around involved exceeding the previous qualification experience both in terms of extreme cold exposure level and in terms of demonstrated low cycle fatigue life for the power shunt assemblies. An analysis was performed to identify potential failure sites, modes and associated failure mechanisms consistent with the new use conditions. A test was then designed and executed which accelerated the failure mechanisms identified by analysis. Verification of the resulting failure mechanism concluded the effort.

Gibbel, Mark↗

Repeatable electrical measurement instrumentation for use in the accelerated stress testing of thin film solar cells

Attention is given to the construction, calibration, and performance of a repeatable measurement system for use in conjunction with the accelerated stress testing of a-Si:H cells. A filtered diode array is utilized to approximate the spectral response of any type of solar cell in discrete portions of the spectrum. It is noted that in order to achieve the necessary degree of overall repeatability, it is necessary to pay particular attention to methods of contacting and positioning the cells.

Davis, C. W.↗