At least 181 records · Page 10

Methodology for designing accelerated aging tests for predicting life of photovoltaic arrays

A methodology for designing aging tests in which life prediction was paramount was developed. The methodology builds upon experience with regard to aging behavior in those material classes which are expected to be utilized as encapsulant elements, viz., glasses and polymers, and upon experience with the design of aging tests. The experiences were reviewed, and results are discussed in detail.

Gaines, G. B.↗

Procedure for developing experimental designs for accelerated tests for service-life prediction

Recommended design procedures to reduce the complete factorial design by retaining information on anticipated important interaction effects, and by generally giving up information on unconditional main effects are discussed. A hypothetical photovoltaic module used in the test design is presented. Judgments were made of the relative importance of various environmental stresses such as UV radiation, abrasion, chemical attack, temperature, mechanical stress, relative humidity and voltage. Consideration is given to a complete factorial design and its graphical representation, elimination of selected test conditions, examination and improvement of an engineering design, and parametric study. The resulting design consists of a mix of conditional main effects and conditional interactions and represents a compromise between engineering and statistical requirements.

Thomas, R. E.↗

Statistical Modeling of Photovoltaic Reliability Using Accelerated Degradation Techniques (Poster)

We introduce a cutting-edge life-testing technique, accelerated degradation testing (ADT), for PV reliability testing. The ADT technique is a cost-effective and flexible reliability testing method with multiple (MADT) and Step-Stress (SSADT) variants. In an environment with limited resources, including equipment (chambers), test units, and testing time, these techniques can provide statisticallyrigorous prediction of lifetime and other interesting parameters, such as failure rate, warranty time, mean time to failure, degradation rate, activation energy, acceleration factor, and upper limit level of stress. J-V characterization can be used for degradation data and the generalized Eyring model can be used for the thermal-humidity stress condition. The SSADT model can be constructed basedon the cumulative damage model (CEM), which assumes that the remaining test united are failed according to cumulative density function of current stress level regardless of the history on previous stress levels.

14 SOLAR ENERGY↗

Space Telescope Fine Guidance Sensor Bearing Anomaly

Early in 1993, a servo motor within one of three Fine Guidance Sensors (FGS) aboard the Hubble Space Telescope (HST) reached stall torque levels on several occasions. Little time was left to plan replacement during the first servicing mission, scheduled at the end of '93. Accelerated bearing life tests confirmed that a small angle rocking motion, known as Coarse Track (CT), accelerated bearing degradation. Saturation torque levels were reached after approximately 20 million test cycles, similar to the flight bearings. Reduction in CT operation, implemented in flight software, extended FGS life well beyond the first servicing mission. However in recent years, bearing torques have resumed upward trends and together with a second, recent bearing torque anomaly has necessitated a scheduled FGS replacement during the upcoming second servicing mission in '97. The results from two series of life tests to quantify FGS bearing remaining life, discussion of bearing on-orbit performance, and future plans to service the FGS servos are presented in this paper.

Loewenthal, S.↗

The GSFC Combined Approach of ODC Stockpiling and Tribological Testing to Mitigate the Risks of ODC Elimination

In response to the elimination of production of several Ozone Depleting Chemicals (ODC's) which have been widely used in successful space flight mechanism cleaning and lubricating procedures, GSFC developed and implemented an overall philosophy of mitigating the risks to flight hardware during the transition phase to ODC-free cleaning procedures. The short term leg of the philosophy was the stockpiling of an appropriate amount of ODC solvents such that all short term GSFC missions will be able to stay with or revert to heritage cleaning and lubricating procedures in the face of life issues. The long-term leg of that philosophy was the initiation of a several tier testing program that will deliver increasing amounts of information over the next few years, starting with accelerated lubricant life tests that compare lubricant life on surfaces cleaned with ODC solvents with lubricant life on surfaces cleaned with ODC-free solvents. While tribological testing, mechanism life testing and space-flight experience will ultimately bring us into the 21st century with environmentally friendly means of cleaning long-life precision mechanism components, many satellites will be launched over the next few years before a number of important tribological questions can be answered. In order to prepare for this challenge, the Materials Engineering Branch in cooperation with the Electromechanical Branch launched an intensive review of all ongoing missions. The failure risk was determined for each long-life lubricated mechanism based on a number of parameters, including 4 comparison of flight solvents used to clean the heritage/life test hardware. Also studied was the ability of the mechanism manufacturers to stockpile ODC's based on state laws and company policies. A stockpiling strategy was constructed based on this information and subsequently implemented. This paper provides an overview of the GSFC ODC elimination risk mitigation philosophy as well as a detailed examination of the development of the ODC stockpiling plan.

Predmore, Roamer↗

NREL Innovations Help Drive Wind Industry Transformation [Fact Sheet]

For nearly 30 years, NREL has helped the wind turbine industry through design and research innovations. The comprehensive capabilities of the National Wind Technology Center (NWTC), ranging from specialized computer simulation tools to unique test facilities, has been used to design, develop, and deploy several generations of advanced wind energy technology.

17 WIND ENERGY↗

Accelerated testing of module-level power electronics for long-term reliability

This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the number of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.

14 SOLAR ENERGY↗

Space-and Ground-Based Non-Accelerated Long Lifetime Data for Ruggedized Commercial Non-Planar Ring Oscillator (NPRO) Lasers

Lifetime data is presented for ruggedized commercial NPRO lasers used in the Tropospheric Emission Spectrometer (TES) Instrument on NASA’s Aura Earth-orbiting spacecraft, including 20 years of data from two life test units on the ground, 12 years of on-orbit data from TES Laser A, and 2 years of on-orbit data from TES Laser B. The TES lasers are diode-pumped Non-Planar Ring Oscillator (NPRO) lasers using Nd:YAG crystals. Since accelerated life testing was not possible on the complete laser, early prototype lasers that had gone through thermal cycling and vibration testing were placed on non-accelerated life tests with the hope of gathering at least a couple of years of data before launch. Long-term lifetime data for hybrid laser systems in space applications is not abundant, and out of necessity, accelerated reliability testing is usually done over a relatively short time with a large number of devices. The data presented in this paper is unique as it tracks the optical power output over time of a total of four lasers on the order of decades rather than months or years. Two of the lasers have each been on life test for over 20 years on the ground and are still operating, and the other two lasers have been on-orbit for 14 years. TES Laser A was still operating when the TES Instrument was decommissioned in January 2018. Therefore, the data presented covers over 450,000 non-accelerated device-hours, with 23% of those hours being in space.

Kane, T.J.↗

The Role of Bearing and Scan Mechanism Life Testing in Flight Qualification of the MODIS Instrument

This paper describes the results of accelerated and operational life tests on bearings for the Moderate Resolution Imaging Spectroradiometer (MODIS). It also describes the post test analysis of the disassembled bearings. Analysis was performed using micro-Raman, micro-FTIR, X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM), and Size Exclusion Chromatography (SEC). In general, the three sets of bearings in each of three test stations were in very good condition after accumulating 68, 144, and 209 million cycles, respectively. Some of the bearings exhibited lubricant degradation, indicated by viscous lubricant deposits on the cage and raceways.

VanDyk, Steven G.↗

Anomalous Transients in Chip Polymer Tantalum Capacitors

Contrary to MnO2 tantalum capacitors, transient processes in polymer tantalum capacitors after voltage application might result in anomalously high, ampere-level currents when a capacitor might appear as a short circuit for a time that is much greater than a transient time in MnO2 capacitors. In this work, conditions that cause anomalous transients in different types of polymer tantalum capacitors have been analyzed. Related phenomena that included increasing of capacitance and dissipation factors with voltage, parametric surge current test failures without damage to capacitors, and increasing leakage currents at low temperatures are described. It has been shown that anomalous transients increased substantially with applied voltage and with reduction of moisture content in capacitors caused by storage or operation at high temperatures and/or in vacuum. Different types of capacitors exhibited different level of transients and modification of conductive polymers or process of their application might decrease transient leakage currents substantially. For space applications, the risk of failures related to anomalous transients can be mitigated by special testing procedures to select parts with an acceptable level of transients and by voltage derating.

Tantalum Capacitors↗

Hotspot testing of glass/backsheet and glass/glass PV modules pre-stressed in extended thermal cycling

This paper investigates the effect of hotspot (HS) stress endurance of two of the latest designs of monocrystalline modules: a half-cell glass/backsheet (G/B) module and a full-cell glass/glass (G/G) module. These modules have already been pre-stressed in extended thermal cycling with 600 cycles per the IEC 61215 standard to represent field-stressed modules. This study differs from the other conventional studies wherein only fresh modules are subjected to hotspot endurance stress. The G/G module reached a maximum temperature of approximately 200 °C at a cell shading of 25 %, 55 °C higher than the maximum hotspot temperature of 145 °C in the G/B module. A significant burn mark, without glass shattering, was observed in the hotspot-stressed cell of the G/G module due to the current mismatch induced by partial shading. Most of the cells in the G/G module appear to be severely damaged (severe dark areas), as observed in the electroluminescence (EL) image, while the dark regions were rarely present in the G/B module. The EL image also illustrates multiple cell cracks that resist current flow and eventually contribute to the full-cell module degradation. About 8.3 % degradation in maximum power was observed for the G/G module and 1.3 % for the G/B module after the sequential stress tests. The lower degradation in the G/B module can potentially be attributed to its design, which comprises of two parallel strings, each having 72-half-cells and benefits from lower heat dissipation. Furthermore, this indicates that the half-cell design could potentially minimize the hotspot degradation and failures in crystalline-silicon modules.

14 SOLAR ENERGY↗

Comparative Analysis of Hotspot Stress Endurance in Pristine and Thermal Cycled Prestressed Glass–Glass Photovoltaic Modules

Hotspots pose a significant long-term reliability challenge in photovoltaic (PV) modules that can have a detrimental impact on the efficiency, safety, and financial viability of a PV system. This paper aims to evaluate the endurance of hotspot stress in pristine and prestressed glass–glass (GG) modules. The accelerated prestressing was conducted for 600 thermal cycles (TC600) to represent decades of field exposure. GG modules are quickly becoming an alternative to the traditional glass–backsheet (GB) modules that have been the industry standard. Unlike other conventional studies that subject only pristine modules to hotspot stress, this paper evaluates the performance of an accelerated/simulated field-aged GG module (using TC600) and a pristine GG module. Pre- and post-characterizations were performed before and after each test to determine changes in electrical performance and observe any defects in GG modules. During the hotspot test, an approximately 200 °C maximum cell temperature was observed with a cell shading of 25% (the worst-case shading ratio). After the hotspot test, electroluminescence imaging indicated that most cells in the prestressed GG module exhibited severe damage whereas no significant defects were evident in the pristine GG module where the prestressed GG module degraded 8.2% and the pristine GG module degraded 1.5% in maximum power. These findings are critical for the industry, considering that GG bifacial modules will dominate the market.

14 SOLAR ENERGY↗

Accelerated Lifetime Testing of Main Shaft Seals for Tidal Turbine Rotors

This document will briefly discuss the observations and results from an NREL conducted accelerated lifetime testing of the main shaft seal for the Verdant Power fifth generation Gen5 underwater Tidal Energy Converter (TEC) turbine, which successfully performed at the RITE project in 2020-2021. In order to evaluate a 5-year Service Interval ( SI) for this component, testing at NREL operated the main shaft seal nearly continuously for over 135 (text says 130 days on page 5 and 125 days on page 7 and 137 days on page 11) days at a rotational velocity of 160 rpm while the test stand recorded water pressure, barrier fluid pressure, temperature, and number of cycles., representing ~ 40% of the SI. An additional separate test was conducted to measure the aging behavior of the rubber drive rings. The water pressure reservoir was held constant as 29 psi. Barrier fluid pressure remained relatively constant throughout the duration of the test but was seen to sink to as low as 10.1 psi. No barrier fluid leakage was observed throughout the test. A sudden failure occurred within the seal after the power to test machine was interrupted for a scheduled building maintenance procedure. Upon restarting, the main shaft seal lost all ability to prevent water ingress. The exact cause is not known but is believed to be either a seal assembly issue or a change in the alignment of the seal components during or following the power outage. Following seal disassembly, significant wear was seen on one of the graphite sealing rings. Based on these results it is recommended that a follow-on TEAMER be conducted to rectify protocol and assembly issues to further evaluate SI of this component. The support and participation of Verdant Power Inc, Dovetail Solutions LLC and Garlock Manufacturing Inc were instrumental in understanding the results. NREL thanks them for their significant effort.

13 HYDRO ENERGY↗

The Effect of 1–10-MeV Neutrons on the JESD89 Test Standard

Here, the JESD89 test standard defines how terrestrial neutron testing is conducted [1] . The test standard covers a number of different types of radiation used for testing, including protons, neutrons, and alphas, and different types of testing, including life testing and accelerated testing. Broad-spectrum neutron testing is the most common type of accelerated radiation testing for the terrestrial radiation environment. Unlike most test standards, the JESD89 defines the minimum energy for determining the cumulative fluence for the deployed and test environment. Currently, the minimum energy is set at 10 MeV. As the test standard is currently being rewritten, changing the minimum energy to 1 MeV is being explored, because it is believed that the onset to neutron-induced single-event effects (SEEs) is less than 10 MeV. There are three separate problems with lowering the minimum energy: determining whether electronics have a sensitivity to neutron-induced SEEs below 10 MeV, determining whether the test spectra match the terrestrial environment in the 1–10-MeV range, and the measurement error caused by not including the fluence from 1 to 10 MeV. In this paper, we present information on these factors and whether the minimum energy should be lowered to 1 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Durability of Poly(Methyl Methacrylate) Lenses Used in Concentrating Photovoltaic Modules: Preprint

Concentrating photovoltaic (CPV) technology has recently gained interest based on their expected low levelized cost of electricity, high efficiency, and scalability. Many CPV systems use Fresnel lenses made of poly(methyl methacrylate)(PMMA) to obtain a high optical flux density. The optical and mechanical durability of such components, however, are not well established relative to the desired service life of 30 years. Specific reliability issues may include: reduced optical transmittance, discoloration, hazing, surface erosion, embrittlement, crack growth, physical aging, shape setting (warpage), and soiling. The initial results for contemporary lens- and material-specimens aged cumulatively to 6 months are presented. The study here uses an environmental chamber equipped with a xenon-arc lamp to age specimens at least 8x the nominal field rate. A broad range in the affected characteristics (including optical transmittance, yellowness index, mass loss, and contact angle) has been observed to date, depending on the formulation of PMMA used. The most affected specimens are further examined in terms of their visual appearance, surface roughness (examined via atomic force microscopy), and molecular structure (via Fourier transform infrared spectroscopy).

14 SOLAR ENERGY↗