Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used in the reconstruction process. Conclusions: The concept of assessing temporal resolution by means of the data employed for reconstruction can nicely be extended from single-source to dual-source CT. However, for advanced (possibly nonlinear iterative) reconstruction algorithms the examined approach fails to deliver accurate results. New methods and measures to assess the temporal resolution of CT images need to be developed to be able to accurately compare the performance of such algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.

60 APPLIED LIFE SCIENCES↗

A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.

60 APPLIED LIFE SCIENCES↗

SU-F-J-161: Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI

Purpose: To investigate the usefulness of metal artifact reduction in CT images of patients with bilateral hip prostheses (BHP) for contouring the prostate and determine if the inclusion of MR images provides additional benefits. Methods: Five patients with BHP were CT scanned using our clinical protocol (140kV, 300mAs, 3mm slices, 1.5mm increment, Philips Medical Systems, OH). Images were reconstructed with the orthopaedic metal artifact reduction (O-MAR) algorithm. MRI scanning was then performed (1.5T, GE Healthcare, WI) with a flat table-top (T{sub 2}-weighted, inherent body coil, FRFSE, 3mm slices with 0mm gap). All images were transferred to Pinnacle (Version 9.2, Philips Medical Systems). For each patient, two data sets were produced: one containing the O-MAR-corrected CT images and another containing fused MRI and O-MAR-corrected CT images. Four genito-urinary radiation oncologists contoured the prostate of each patient on the O-MAR-corrected CT data. Two weeks later, they contoured the prostate on the fused data set, blinded to all other contours. During each contouring session, the oncologists reported their confidence in the contours (1=very confident, 3=not confident) and the contouring difficulty that they experienced (1=really easy, 4=very challenging). Prostate volumes were computed from the contours and the conformity index was used to evaluate inter-observer variability. Results: Larger prostate volumes were found on the O-MAR-corrected CT set than on the fused set (p< 0.05, median=36.9cm{sup 3} vs. 26.63 cm{sup 3}). No significant differences were noted in the inter-observer variability between the two data sets (p=0.3). Contouring difficulty decreased with the addition of MRI (p<0.05) while the radiation oncologists reported more confidence in their contours when MRI was fused with the O-MAR-corrected CT data (p<0.05). Conclusion: This preliminary work demonstrated that, while O-MAR correction to CT images improves visualization of anatomy, the addition of MRI enhanced the oncologists’ confidence in contouring the prostate in patients with BHP.

60 APPLIED LIFE SCIENCES↗

Nonproliferation Legacy Technology and Artifact Collection: NASA Space Shuttle Tiles

The NASA Space Shuttle Tiles were used by Sandia in the process of developing the Laser Dynamic Range Imager (LDRI) in support of NASA's Return to Flight following the 2003 Space Shuttle Columbia disaster. The heat shield tiles, provided to Sandia by NASA, are identical to those that were located on the underbelly of the Space Shuttle Columbia's orbiter. Sandia used the tiles to test the efficacy of the LDRI's imaging capabilities. The LDRI was utilized during every space shuttle mission between 2005 and 2011. The tiles are currently located in Building 891 and need to be moved to free up space for operational use. Given their technical significance, Sandia would like to archive them as historically significant items in long-term storage until such time as they can be appropriately displayed or employed as a demonstration artifact. This document provides basic information about the provenance of this artifact.

42 ENGINEERING↗

Witness the Trinity test through Lab artifacts

July 16 marks the 77th anniversary of the Trinity test, conducted in a desert in New Mexico. The test subject, an atomic bomb called The Gadget, was successfully detonated from a 100-foot steel tower. This event marks the commencement of the Atomic Age, a new era where fission capabilities could be employed for national security purposes. Shortly after the Trinity test, two Los Alamos-created atomic weapons were released above Japan, helping to end the world’s bloodiest conflict just weeks later. “Trinity was one of the greatest scientific experiments ever,” said NSRC Senior Historian Alan Carr said. “Los Alamos scientists changed the world forever on that day. Not only was it the dawn of the Atomic Age, but also the beginning of the Lab’s eight decades of cutting-edge science and its national security charge.” To preserve this event, and to continue to learn more about this critical moment in history, the National Security Research Center (NSRC) curates a collection of photographs, films, notes, unclassified artifacts and numerous other materials related to the science of the test. Notably, the collection includes a novel material that formed at the site, trinitite, and artifacts from one of the intriguing scientists present at the test, Enrico Fermi.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Specimen Size Artifacts Associated with a Glovebox Deployable Laser Flash Diffusivity Measurement System

To accelerate nuclear fuel qualification and deployment efforts, Oak Ridge National Laboratory has led the world in developing vehicles for accelerating burnup accumulation in nuclear fuel by testing miniature samples in the High Flux Isotope Reactor. However, a challenge remains to establish parity between post irradiation characterization methods for miniature fuel specimens in comparison to conventional fuel elements. This work aims to identify artifacts associated with the thermal analysis of miniature disk specimens in comparison to samples of standardized dimensions through a combination of experimental and computational tools. Using a newly procured Netzsch 427 laser flash diffusivity system, preliminary data on mild steel specimens were collected, and finite element techniques were used to model heat transfer using 1D conditions to assess issues associated with pulse width and data collection frequency effects. These preliminary investigations found that significant variability in measured thermal diffusivity exist within datasets. These variations are not necessarily attributed to limitations with respect to data collection rate; nor are they associated with limitations on pulse width. Instead, these artifacts may be a result of limitations in detector intensity. Future work aims to design a focusing lens to better measure the smaller surface area of miniature specimens analyzed using the laser flash analysis system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Probing for Artifacts: Detecting Imagenet Model Evasions

While deep learning models have made incredible progress across a variety of machine learning tasks, they remain vulnerable to adversarial examples crafted to fool otherwise trustworthy models. In this work we approach this problem through the lens of a detection framework. We propose a classification network that uses the hidden layer activations of a trained model as inputs to detect adversarial artifacts in an input. We train this classification network simultaneously against multiple adversarial algorithms to create a more robust detector and show higher detection rates than several alternatives. The novelty of our approach is in the scale and scope of probing Imagenet models for adversarial artifacts. In addition, we propose an improvement to feature squeezing, another common adversarial example detection method.

Rounds, Jeremiah↗

Synchrotron radiation-based x-ray analysis of bronze artifacts from an Iron Age site in the Judean hills.

Seven bronze bangles from Tell en-Nasbeh, northern Judah, were investigated to understand the phase composition and manufacturing process of the artifacts, and possibly suggest a provenance for their origin. Synchrotron x-ray radiation diffraction (XRD) and fluorescence (XRF) were used in the analysis to avoid any destructive sampling and at the same time penetrate through the surface into the core metal. These techniques enabled us to determine that the bangles were not just tin bronze, but leaded tin bronze. Based on excavation reports, it is unlikely that the metal objects were manufactured locally at Tell en-Nasbeh; rather, preliminary XRD and XRF data point towards the neighboring region of Edom as their origin. Despite their political enmity during the Iron Age II, the data suggest that Judahite social demands for bronze may have fostered a strong economic relationship between these two polities.

43 PARTICLE ACCELERATORS↗

A new oxidation based technique for artifact free TEM specimen preparation of nuclear graphite

Graphite is a key component in designs of current and future nuclear reactors whose in-service lifetimes are dependent upon the mechanical performance of the graphite. Irradiation damage from fast neutrons creates lattice defects which have a dynamic effect on the microstructure and mechanical properties of graphite. Transmission electron microscopy (TEM) can offer real-time monitoring of the dynamic atomic-level response of graphite subjected to irradiation; however, conventional TEM specimen-preparation techniques, such as argon ion milling itself, damage the graphite specimen and introduce lattice defects. It is impossible to distinguish these defects from the ones created by electron or neutron irradiation. Thus,to ensure that TEM specimens are artifact-free, a new oxidation-based technique has been developed. Bulk nuclear grades of graphite (IG-110 and NBG-18) and highly oriented pyrolytic graphite (HOPG) were initially mechanically thinned to ~60μm. Discs 3mm in diameter were then oxidized at temperatures between 575°C and 625°C in oxidizing gasses using a new jet-polisher-like set-up in order to achieve optimal oxidation conditions to create self-supporting electron-transparent TEM specimens. The quality of these oxidized specimens were established using optical and electron microscopy. Samples oxidized at 575°C exhibited large areas of electron transparency and the corresponding lattice imaging showed no apparent damage to the graphite lattice.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Origin and Suppression of Beam Damage-Induced Oxygen-K Edge Artifact from γ-Al 2 O 3 using Cryo-EELS

Gamma-alumina (γ-Al 2 O 3 ), like other low-Z oxides, is readily damaged when exposed to an electron beam. This typically results in the formation of a characteristic pre-edge peak in the oxygen-K edge of electron energy-loss spectra (EELS) acquired during or after the damage process. This artifact can mask the presence of intrinsic O-K edge fine structure that would reveal chemical properties of the material; therefore, its suppression is key. In this work, we systematically investigate the conditions that give rise to the damage-induced O-K pre-edge peak and show that it can be effectively suppressed by performing EELS experiments at cryogenic (cryo) temperatures. Prolonged exposure of γ-Al 2 O 3 to a focused electron beam results in a hole bored through the sample; this was used as a reproducible beam damage condition. O-K edge EELS spectra were collected from a single-crystal γ-Al 2 O 3 sample both during and after focused 2 electron beam hole drilling, and at room and cryo temperatures, using a monochromated scanning transmission electron microscope (STEM). Furthermore, the characteristic 531 eV pre-edge peak visible in the room temperature EELS spectra was completely suppressed in the cryo-EELS spectra, even in the presence of a visible drilled hole. We then correlated these experimental observations with multiple-scattering EELS simulations to determine the likely atomistic origin of the damage-induced O-K pre-edge peak. The findings indicate that the pre-edge peak is caused primarily by the presence of surface O dimer (O-O) bonds formed during beam damage, and that operating at cryo temperature suppresses the formation of surface O-O bonds, thus preventing formation of the O-K pre-edge peak. Additionally, Al-L 2,3 edge EELS spectra revealed Al loss primarily from tetrahedral sites during hole drilling.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of Sulfur and Nanostructured Sulfur Battery Cathodes in Electron Microscopy Without Sublimation Artifacts

Abstract Lithium sulfur (Li–S) batteries have the potential to provide higher energy storage density at lower cost than conventional lithium ion batteries. A key challenge for Li–S batteries is the loss of sulfur to the electrolyte during cycling. This loss can be mitigated by sequestering the sulfur in nanostructured carbon–sulfur composites. The nanoscale characterization of the sulfur distribution within these complex nanostructured electrodes is normally performed by electron microscopy, but sulfur sublimates and redistributes in the high-vacuum conditions of conventional electron microscopes. The resulting sublimation artifacts render characterization of sulfur in conventional electron microscopes problematic and unreliable. Here, we demonstrate two techniques, cryogenic transmission electron microscopy (cryo-TEM) and scanning electron microscopy in air (airSEM), that enable the reliable characterization of sulfur across multiple length scales by suppressing sulfur sublimation. We use cryo-TEM and airSEM to examine carbon–sulfur composites synthesized for use as Li–S battery cathodes, noting several cases where the commonly employed sulfur melt infusion method is highly inefficient at infiltrating sulfur into porous carbon hosts.

25 ENERGY STORAGE↗

The Application and Potential Artifacts of Zeeman Cold Vapor Atomic Absorption Spectrometry in Mercury Stable Isotope Analysis

Zeeman cold vapor atomic absorption spectrometry (CVAAS) has been widely used for environmental mercury (Hg) detection and quantification for decades, but little is known about its utility and potential artifacts in analyzing Hg with varying isotope compositions. We show that each Hg isotope responds differently by CVAAS analysis, with 200 Hg and 202 Hg isotopes exhibiting signal intensities ~10 times greater than those of 198 Hg and 201 Hg isotopes. However, all Hg isotopes show a linear correlation between Hg concentration and signal intensity, validated by both measurements and theoretical simulations. Zeeman CVAAS could thus offer a convenient, inexpensive tool for determining Hg isotopes, particularly in using one or two enriched Hg isotopes for tracing Hg biogeochemical transformations, such as partitioning, ion exchange, sorption–desorption, and methylation–demethylation in environmental matrices. Additionally, we caution that care must be taken when CVAAS is used for quantifying Hg in samples with changing isotope compositions to avoid measurement errors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduced Artifact Approach for Determining Diffusion Coefficients in Time-Resolved Microscopy

Ultrafast microscopy methods traditionally assume a Gaussian profile to extract excited state diffusivities from transport measurements. Although this fitting method recovers accurate diffusion coefficients when the point spread function is well-represented by a Gaussian, even minor spatial aberrations introduced by the imaging system cause significant errors in the determined value. To provide a more accurate measure of excited state transport in nano- and microscale materials systems, in this work an alternative analysis protocol is proposed that numerically convolves the Green’s function solution to the diffusion equation with the experimentally measured point spread function. In contrast to the Gaussian fitting approach, the numerical convolution is shown to be robust against artifacts caused by nonideal point spread functions. Furthermore, the numerical convolution approach is highly effective at resolving anisotropic diffusion in modeled data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MRI Artifacts of a Metallic Stent Derived From a Human Aorta Specimen

Magnetic resonance imaging has proved to be a useful technique to get images of the whole body. However, the presence of ferromagnetic material can cause susceptibility artifacts, which result from microscopic gradients that occur near the boundaries between areas displaying different magnetic susceptibility. These gradients cause dephasing of spins and frequency shifts in the surrounding tissues. Intravoxel dephasing and spatial mis-registration can degrade image quality. An aorta with a metallic stent was preserved in formaldehyde at 10% inside acrylic cylinders and used to obtain MR images. We tested pulsed spin echo and gradient echo sequences to improve image quality. All experiments were performed on a 7T/21 cm Varian system (Varian, Inc, Palo Alto, CA) equipped with Direct Drive technology and a 16-rung birdcage coil transceiver. The presence of metallic stents produces a lack of signal that might give falsely reassuring appearances within the vessel lumen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Artifacts in X-ray Dark-Field Tomography

Grating-based x-ray imaging provides three principle kinds of contrast: absorption, phase, and dark-field. Due to the availability of tomographic reconstruction algorithms for the dark-field contrast, it is now possible to take advantage of quantitative scatter information. However, the published algorithm is based on several assumptions that might be violated in reality. We use numerical simulations in order to identify artifacts in the reconstructions, which is crucial for the interpretation of experimental data.

07 ISOTOPE AND RADIATION SOURCES↗