Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

6 um Pulsed OP-GaAs OPO Laser for Unambiguous Water Ice Detection on the Moon and Other Planetary Bodies

NASA demands a laser transmitter for planetary remote sensing to detect water-ice on the Moon and other planetary bodies. Based on the measurement of the Moon Mineralogy Mapper (M3) instrument, the discovery of water ice on the Moon was acclaimed, but the measurement is disputed because OH- and/or H2O-bearing materials share the absorption line around 3 μm wavelength. Lunar Flashlight, another mission project exploring the surface of Moon which will be launched later this year, enables to map the minerals on dark area of the Moon, but could not resolve the above-mentioned ambiguity. The absorption of 6.08 μm light is uniquely associated with the bending resonance of H2O since there is no comparable vibration in confounding OH-bearing materials. 6.08 μm laser between the atmospheric windows: middle-wave infrared (3-5 μm) and long-wave infrared (8-12 μm) has not been commercially available. Our approach is a Q-switched Ho:YLF laser pumped the orientation-pattern Gallium Arsenide optical parametric oscillator (OP-GaAs OPO) for generating high-energy laser pulses at the wavelength of 6.08 μm. In the current design, a 1.94 μm Tm:fiber is used as the pump source. In the compact design, a 1.94 μm laser diode will replace the Tm:fiber laser as the pump source. We will combine this proposed mid-infrared laser with the latest HgCdTe avalanche photodiode (APD) array to design a lidar for detecting water ice on the Moon and Mars from their respective orbits, enabling novel science and in-situ resource utilization. Our instrument is an enabling technology aboard the Artemis program and others.

mid-infrared laser↗

A Dedicated, Long Duration Balloon Mission from Antarctica to Measure the Effects of Low Dose Galactic Cosmic Radiation on Biology

Antarctic long duration balloon missions flown by NASA’s Science Mission Directorate (SMD)can be used as a surrogate for the deep space radiation environment, reducing the need to launch orbital experiments to assess the impact of galactic cosmic radiation (GCR) on biology. To date, over fifty NASA balloon missions flown from Antarctica have carried scientific payloads from Astrophysics (APD) and Heliophysics (HPD)in SMD. Only two life science experiments have been flown from Antarctica, and both were ride-along (piggyback) opportunities, limiting the sophistication and types of model organisms that can be incorporated into studies. Herein, we argue for establishing a large, dedicated Antarctic balloon mission for the Biological and Physical Sciences (BPS) Division in SMD to be launched in 2029/2030, with an “omnibus” gondola carrying dozens of independent Space Biology payloads that would receive a sustained exposure to low dose rate GCRs for 30+ days. Our unprecedented, protracted radiation experiment cannot be done using ground-based simulation facilities or in space; it can only be achieved through an Antarctic balloon mission dedicated to BPS Division payloads. By providing more access to radiation research platforms through existing NASA SMD access to Antarctic balloon flight opportunities, the Space Biology community will be better positioned to address unknowns associated with low dose rate GCR exposures in long duration spaceflight.

David J Smith↗

A Direct Detection LiDAR Detector for the Europa Lander Concept

NASA's Jet Propulsion Laboratory is developing a Europa Lander astrobiology mission concept to search for biosignatures within Europa’s subsurface. However, Europa’s rugged terrain presents a number of physical hazards for landing. MIT Lincoln Laboratory is designing a radiation-hardened real-time direct-detection LIDAR system at 532nm to aid with autonomous hazard avoidance and landing site selection for this Europa Lander concept. The detector for this system is a 2048x32 array of silicon Geiger-mode APDs and covers the required field-of-view in one dimension, removing the need for 2D stitching and enabling real-time data processing. Detector design, improvements for radiation tolerance and component characterization results are presented.

San Martin, Alejandro Miguel↗

Development and Airborne Demonstration of the Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System: Advancing Lidar Capabilities for the STV Observing System

We report on the design, build and planned airborne demonstration of a spaceflight-prototype Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS). The CASALS lidar is an Adaptive Wavelength Scanning Lidar (AWSL) operating in push broom mode. The demonstration has three major goals: advance the Technical Readiness Level of the AWSL hardware, validate its measurement performance and mature algorithms and methods needed for the Surface Topography and Vegetation (STV) observing system. AWSL acquires parallel tracks of surface heights by rapidly steering a laser beam across a swath. A 1040nm-centered laser is tuned across 30nm and carved into 2-ns pulses, the pulse energy is fiber amplified and the pulses are dispersed cross-track using a non-mechanical wavelength-to-angle grating. For the spaceflight system the beam will be pointable to 1200 10m footprints across a 7km swath. For the airborne demonstration there will be 256 0.7m footprints across a 110m swath. In both cases the footprints overlap across- and along-track for uniform target illumination. For the airborne demonstration a steering mirror will increase the accessible swath width to 4km. At the receiver, solar radiation is filtered with a narrow-slit grating-spectrometer and the footprints are imaged onto a linear-mode, photon-sensitive HgCdTe APD-array. The received pulses are time-division-multiplexed to a few high-speed analog-to-digital converters to record waveforms. Spaceflight and airborne CASALS are designed to nominally detect 20 photons per pulse and, by averaging 27 overlapping footprints, achieve 2cm flat target range precision and high-quality vegetation structure waveforms The AWSL will be flown in the summer of 2024, along with a Headwall VNIR-SWIR hyperspectral sensor imaging a 4km wide swath, at NEON eddy covariance flux towers in the U.S. mid-Atlantic where high resolution hyperspectral and lidar data, acquired annually, are available for validation.

Guangning Yang↗

Rapid Variability of Mrk 421 During Extreme Flaring as Seen Through the Eyes of XMM-Newton

By studying the variability of blazars across the electromagnetic spectrum, it is possible to resolve the underlying processes responsible for rapid flux increases, so-called flares. We report on an extremely bright X-ray flare in the high-peaked BL Lacertae object Markarian 421 (Mrk 421) that occurred simultaneously with enhanced γ-ray activity detected at very high energies by First G-APD Cherenkov Telescope on 2019 June 9. We triggered an observation with XMM–Newton, which observed the source quasi-continuously for 25 h. We find that the source was in the brightest state ever observed using XMM–Newton, reaching a flux of 2.8 × 10 −9 erg cm -2 s -1 over an energy range of 0.3–10 keV. We perform a spectral and timing analysis to reveal the mechanisms of particle acceleration and to search for the shortest source-intrinsic time-scales. Mrk 421 exhibits the typical harder-when-brighter behaviour throughout the observation and shows a clock-wise hysteresis pattern, which indicates that the cooling dominates over the acceleration process. While the X-ray emission in different sub-bands is highly correlated, we can exclude large time lags as the computed z-transformed discrete correlation functions are consistent with a zero lag. We find rapid variability on time-scales of 1 ks for the 0.3–10 keV band and down to 300 s in the hard X-ray band (4–10 keV). Taking these time-scales into account, we discuss different models to explain the observed X-ray flare, and find that a plasmoid-dominated magnetic reconnection process is able to describe our observation best.

acceleration of particles↗

Linking Strategic Astrophysics Missions, Technology Gaps, and Technology Maturation Investments

The National Aeronautics and Space Administration’s (NASA) Astrophysics Division (APD) funds the development of cutting-edge technologies through multiple programs to enable its strategic missions to achieve ambitious and groundbreaking science goals. These technology development efforts are managed by the Cosmic Origins (COR), Exoplanet Exploration (ExE), and Physics of the Cosmos (PhysCOS) programs. The 2020 Astronomy and Astrophysics Decadal Survey, “Pathways to Discovery in Astronomy and Astrophysics for the 2020s,” (Astro2020) recommended a pan-chromatic set of missions, including three Great Observatories (GO) and three Probe-class missions that could collect unprecedented data over the coming decades. We show the correlation between these strategic missions and the current Astrophysics technology gaps, as well as recent and current technology maturation projects funded to help close these technology gaps. We also cover how these investments advanced their Technology Readiness Levels (TRLs) [1] and where they have been infused into missions and projects.

SAT↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The BDX detector prototype for dark matter searches in a Beam Dump eXperiment at JLAB

The Beam Dump eXperiment (BDX) is an electron-beam thick-target experiment aimed to investigate the existence of light dark matter particles in the MeV-GeV mass range at Jefferson Lab. A small-scale prototype (BDX-Proto) of the BDX detector has been constructed in order to validate the proposed design and to demonstrate with real measurements the capability to efficiently reject the cosmogenic backgrounds. Here we report the peformance of BDX-Proto extracted from a long campaign of cosmic ray measurements performed at INFN, Sez. Catania and INFN, LNS.

calorimeters↗

A measurement of absolute efficiency of the ARAPUCA photon detector in liquid argon

In the Fall of 2017, two photon detector designs for the Deep Underground Neutrino Experiment (DUNE) Far Detector were installed and tested in the TallBo liquid argon (LAr) cryostat at the Proton Assembly (PAB) facility, Fermilab. The designs include two light bars developed at Indiana University and a photon detector based on the ARAPUCA light trap engineered by Colorado State University and Fermilab. The performance of these devices is determined by analyzing 8 weeks of cosmic ray data. The current paper focuses solely on the ARAPUCA device as the performance of the light bars will be reported separately. The article briefly describes the ARAPUCA concept, the TallBo setup, and focuses on data analysis and results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies in pulse shape discrimination for an optimized ASIC design

The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate scintillator. At the same time, the large number of channels in a typical array calls for the development of low-cost and low-power electronics. A custom integrated circuit (ASIC) is an ideal solution for this purpose. To assess the requirements for such an ASIC, studies were performed using two scintillators, Stilbene and EJ-276, coupled to a 6 x 6 mm SiPM from Onsemi. We demonstrate that both scintillators are viable for performing PSD for interaction energies from 100 keV to several MeV while optimizing the integration periods used in the PSD metric. These measurements inform the design parameters of the ASIC under development.

Si-PMTs↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating resource-efficient neutron/gamma classification ML models targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial field-programmable gate arrays (FPGAs) or synthesized custom blocks on application specific integrated circuits (ASICs). However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series silicon photomultiplier (SiPM) to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10 -3 . The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

47 OTHER INSTRUMENTATION↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Neutron detection efficiency measurements of organic glass scintillator arrays

We characterize the neutron detection efficiency of pixelated organic glass scintillator (OGS) arrays manufactured in two ways: an additive method in which the OGS is cast in place in a pixelated mold, and a subtractive method in which the scintillator is first cast as a large block before being cut in bars and bonded together to form the array. The cast-in-place array utilizes a mixture of “bis(9,9-dimethyl-9H-fluoren-2-yl)diphenylsilane” (P2), “tri([1,1'-biphenyl]-4-yl)(phenyl)silane” (PB3), and “4-bis(2-methylstyryl)benzene” (MSB), and 50% by weight of polystyrene is added to the mixture for subtractive manufactured array. We compare the performance of the OGS arrays to that of an EJ-299-33M plastic scintillator array that was manufactured using a subtractive process similar to that of the second OGS array.

Neutron detectors (cold, thermal, fast neutrons)↗

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗