Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AIRFLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Assembling the SSR2 Cavities String for PIP-II

Characterization of the interaction between airflow and a superconducting radio frequency cavity for particle accelerators in an ultra-clean environment

Tamburrino, Alessandro [Pisa U.]↗

Design, Fabrication and On-Sun Performance Evaluation of SiC Receiver Feature Specimens for CST Applications Using Additively Manufactured SiC Materials

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Successful development of CST systems to generate heat for industrial applications requires significant increase in temperature capability and techno-economically viability of the receiver systems. Supported by an award from the Solar Technology Office (SETO), US Department of Energy (DOE), GE Aerospace Research in collaboration with Heliogen Holdings Inc and Sandia National Lab, is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. The program objective is to demonstrate SiC receiver with air exit temperatures up to 1100 oC and high thermal efficiencies. We report design, fabrication and on-sun test results of SiC components of a prototype 50kW (thermal) HOTSSTAR module. The receiver module architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around a SiC center absorber. The SiC components are fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the reliability and to minimize the risk of cracking damage of SiC test articles in thermal gradient and thermal shock environment of the application, the components were laminated with GE’s MI SiC-SiC CMC. Following extensive design and lab test analyses, selected SiC component designs are tested at Heliogen Lancaster Solar field under highly concentrated solar fluxes around 2000 suns to assess the thermal performance characteristics under realistic field conditions. We report on the test results and compare the thermal performances of different HOTSSTAR SiC absorbers. Finally, we discuss fabrication and initial assembly of a 50kW prototype test module in preparation of on-sun field tests to assess the performance of our final design.

CST, CSP, high temperature, air receiver, SiC, add↗

Performance Evaluation of an Additively Manufactured ultra-High Operating Temperature SiC Solar-Thermal Air Receiver (HOTSSTAR) Test Module

Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal and solar power systems. GE Aerospace Research in collaboration with Heliogen Inc and Sandia National Laboratories (SNL) is engaged in the development of ultra-High Operating Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing. HOTSSTAR goal is to demonstrate SiC receiver with air exit temperatures up to 1100oC. We discuss fabrication and on-sun test results of a prototype 50kWth test module. The receiver architecture is based on a radial airflow design and consists of a series of radial SiC receiver sectors organized around central absorber. These components were fabricated using binder-jet printed SiC followed by melt-infiltration reaction bonding process. To enhance the thermo-mechanical reliability of SiC test articles in thermal gradient/ shock environment of the application, the components were laminated with GE’s MI SiC CMC. A dedicated test facility was constructed at SNL Solar Tower to evaluate the operational performance of HOTSSTAR module under solar fluxes >200 W/cm2. We report on our final 50kW test module fabrication, integration at the test facility at Sandia, and discuss on-sun test results. We compare the performance of HOTSSTAR module relative to our model predictions.

14 SOLAR ENERGY↗

Thermal Management Solution for an Integrated Outer-Rotor Motor Drive: Opportunities and Challenges

This work highlights an integrated thermal management solution for the outer-rotor motor (ORM) drive. The integrated ORM drive utilizes water-ethylene glycol coolant for power electronics and stator cooling. Air cooling is used for rotor laminations, magnets and outer-rotor structures, and the rotor shaft. To fully understand the performance of the integrated ORM drive and thermal management coupling effects, a full drive conjugate heat transfer model has been developed to investigate coupled cooling performance of various components of the ORM drive. Various motor rotational speeds, power output scenarios, and cooling options for the integrated ORM drive have been investigated. The model estimates the operating window for the ORM drive while keeping component operating temperatures below prescribed limits. The model also highlights the importance of windage losses at higher rotational speeds for this ORM design, which involves higher rotor surface area per unit width of the rotor. Different designs are also investigated, particularly focusing on rotor cooling with air either naturally induced by rotor spin or forced airflow with the help of a blower, to circumvent challenges imposed by higher windage losses. The work highlights motor rotational speed limitations and the need for potential liquid cooling options for desired rotor performance at higher rotational speeds. Liquid cooling for the rotor may even become more critical for nonuniform rotor-stator gaps, leading to even higher and uneven windage losses across the full circumference of the motor, consequentially, more heating for the rotor.

30 DIRECT ENERGY CONVERSION↗

A Field and Laboratory Study to Characterize Fault Prevalence in Residential Comfort Systems

This report describes a project whose goal was to determine the prevalence of residential comfort system faults. The focus is on air conditioners and heat pumps, and on key faults that can occur during installation and have significant impacts on performance: (1) incorrect refrigerant charge level (undercharge or overcharge); (2) indoor coil airflow rate; (3) liquid line restrictions; (4) non-condensable gas in the refrigerant; and (5) duct leakage. In addition to quantifying fault prevalence, we collected metadata that could be studied to determine whether there are correlations that suggest drivers of fault prevalence, such as regional variations in practice, economic factors, climatic impacts, and others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical Ventilation and Indoor Air Quality in Recently Constructed U.S. Homes in Marine and Cold-Dry Climates Data from Building America Project

Data were collected to characterize whole-house mechanical ventilation (WHMV) and indoor air quality (IAQ) in 55 homes in the Marine climate of Oregon and Cold-Dry climate of Colorado in the U.S. Sixteen homes were monitored for two weeks, with and without WHMV operating. Ventilation airflows; airtightness; time-resolved CO2, PM2.5 and radon; and time-integrated NO2, NOX and formaldehyde were measured. Participants provided information about IAQ-impacting activities, perceptions and ventilation use. All homes had operational cooktop ventilation and bathroom exhaust. Thirty homes had equipment that could meet the ASHRAE 62.2-2010 standard with continuous or controlled runtime and 34 had some WHMV operating as found. Thirty-five of 46 participants with WHMV reported they did not know how to operate it, and only half of the systems were properly labeled. Two-week homes had lower formaldehyde, radon, CO2, and NO (NOX-NO2) when operated with WHMV; and also had faster PM2.5 decays following indoor emission events. Overall IAQ satisfaction was similar in Oregon and Colorado, but more Colorado participants (19 vs. 3%) felt their IAQ could be improved and more reported dryness as a problem (58 vs. 14%). The collected data indicate that there are benefits of operating WHMV, even when continuous use may not be needed because outdoor pollutant concentrations are low and indoor sources do not present substantial challenges.

air quality↗

Biofilm mitigation in hybrid chemical-biological upcycling of waste polymers

Accumulation of plastic waste in the environment is a serious global issue. To deal with this, there is a need for improved and more efficient methods for plastic waste recycling. One approach is to depolymerize plastic using pyrolysis or chemical deconstruction followed by microbial-upcycling of the monomers into more valuable products. Microbial consortia may be able to increase stability in response to process perturbations and adapt to diverse carbon sources, but may be more likely to form biofilms that foul process equipment, increasing the challenge of harvesting the cell biomass. To better understand the relationship between bioprocess conditions, biofilm formation, and ecology within the bioreactor, in this study a previously-enriched microbial consortium (LS1_Calumet) was grown on (1) ammonium hydroxide-depolymerized polyethylene terephthalate (PET) monomers and (2) the pyrolysis products of polyethylene (PE) and polypropylene (PP). Bioreactor temperature, pH, agitation speed, and aeration were varied to determine the conditions that led to the highest production of planktonic biomass and minimal formation of biofilm. The community makeup and diversity in the planktonic and biofilm states were evaluated using 16S rRNA gene amplicon sequencing. Results showed that there was very little microbial growth on the liquid product from pyrolysis under all fermentation conditions. When grown on the chemically-deconstructed PET the highest cell density (0.69 g/L) with minimal biofilm formation was produced at 30°C, pH 7, 100 rpm agitation, and 10 sL/hr airflow. Results from 16S rRNAsequencing showed that the planktonic phase had higher observed diversity than the biofilm, and that Rhodococcus, Paracoccus, and Chelatococcus were the most abundant genera for all process conditions. Biofilm formation by Rhodococcus sp. And Paracoccus sp. Isolates was typically lower than the full microbial community and varied based on the carbon source. Ultimately, the results indicate that biofilm formation within the bioreactor can be significantly reduced by optimizing process conditions and using pure cultures or a less diverse community, while maintaining high biomass productivity. The results of this study provide insight into methods for upcycling plastic waste and how process conditions can be used to control the formation of biofilm in bioreactors.

36 MATERIALS SCIENCE↗

Development of Advanced Smart Ventilation Controls for Residential Applications

This study examined the use of zoned ventilation systems using a coupled CONTAM/EnergyPlus model for new California dwellings. Several smart control strategies were developed with a target of halving ventilation-related energy use, largely through reducing dwelling ventilation rates based on zone occupancy. The controls were evaluated based on the annual energy consumption relative to continuously operating non-zoned, code-compliant mechanical ventilation systems. The systems were also evaluated from an indoor air quality perspective using the equivalency approach, where the annual personal concentration of a contaminant for a control strategy is compared to the personal concentration that would have occurred using a continuously operating, non-zoned system. Individual occupant personal concentrations were calculated for the following contaminants of concern: moisture, CO2, particles, and a generic contaminant. Zonal controls that saved energy by reducing outside airflow achieved typical reductions in ventilation-related energy of 10% to 30%, compared to the 7% savings from the unzoned control. However, this was at the expense of increased personal concentrations for some contaminants in most cases. In addition, care is required in the design and evaluation of zonal controls, because control strategies may reduce exposure to some contaminants, while increasing exposure to others.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Arctic observations and numerical simulations of surface wind effects on Multi-Angle Snowflake Camera measurements

Abstract. Ground-based measurements of frozen precipitation are heavily influenced by interactions of surface winds with gauge-shield geometry. The Multi-Angle Snowflake Camera (MASC), which photographs hydrometeors in free-fall from three different angles while simultaneously measuring their fall speed, has been used in the field at multiple midlatitude and polar locations both with and without wind shielding. Here, we present an analysis of Arctic field observations – with and without a Belfort double Alter shield – and compare the results to computational fluid dynamics (CFD) simulations of the airflow and corresponding particle trajectories around the unshielded MASC. MASC-measured fall speeds compare well with Ka-band Atmospheric Radiation Measurement (ARM) Zenith Radar (KAZR) mean Doppler velocities only when winds are light (≤5ms-1) and the MASC is shielded. MASC-measured fall speeds that do not match KAZR-measured velocities tend to fall below a threshold value that increases approximately linearly with wind speed but is generally <0.5ms-1. For those events with wind speeds ≤1.5ms-1, hydrometeors fall with an orientation angle mode of 12∘ from the horizontal plane, and large, low-density aggregates are as much as 5 times more likely to be observed. Simulations in the absence of a wind shield show a separation of flow at the upstream side of the instrument, with an upward velocity component just above the aperture, which decreases the mean particle fall speed by 55 % (74 %) for a wind speed of 5 m s−1 (10 m s−1). We conclude that accurate MASC observations of the microphysical, orientation, and fall speed characteristics of snow particles require shielding by a double wind fence and restriction of analysis to events where winds are light (≤5ms-1). Hydrometeors do not generally fall in still air, so adjustments to these properties' distributions within natural turbulence remain to be determined.

54 ENVIRONMENTAL SCIENCES↗

University of Nebraska unmanned aerial system (UAS) profiling during the LAPSE-RATE field campaign

Abstract. This paper describes the data collected by the University of Nebraska-Lincoln (UNL) as part of the field deployments during the Lower Atmospheric Process Studies at Elevation – a Remotely-piloted Aircraft Team Experiment (LAPSE-RATE) flight campaign in July 2018. The UNL deployed two multirotor unmanned aerial systems (UASs) at multiple sites in the San Luis Valley (Colorado, USA) for data collection to support three science missions: convection initiation, boundary layer transition, and cold air drainage flow. We conducted 172 flights resulting in over 21 h of cumulative flight time. Our novel design for the sensor housing onboard the UAS was employed in these flights to meet the aspiration and shielding requirements of the temperature and humidity sensors and to separate them from the mixed turbulent airflow from the propellers. Data presented in this paper include timestamped temperature and humidity data collected from the sensors, along with the three-dimensional position and velocity of the UAS. Data are quality-controlled and time-synchronized using a zero-order-hold interpolation without additional post-processing. The full dataset is also made available for download at https://doi.org/10.5281/zenodo.4306086 (Islam et al., 2020).

Islam, Ashraful (ORCID:000000022826269X)↗

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

42 ENGINEERING↗

Characterization of Mechanical Ventilation Systems in New US Homes: What types of systems are out there and are they functioning as intended?

As the airtightness of homes improves to meet energy efficiency goals, it becomes more important for mechanical ventilation systems to help maintain a comfortable and healthy indoor air environment. ASHRAE Standard 62.2 provides national guidance for mechanical ventilation system design and installation, however adoption of those guidelines into local building codes has occurred at different rates. Once provisions for mechanical ventilation are adopted in a local code, are mechanical ventilation systems properly designed, installed, commissioned and operated according to code or above code program requirements? Is there a need for further industry and homeowner education to ensure systems function as intended? This paper presents results from field studies that include characterization of mechanical ventilation systems in over 150 new homes in CA, CO, FL, GA, IL, OR, and SC built between 2011 and 2018. In each of the study homes, airflow of local (kitchen, bathrooms) and whole-house ventilation were measured. Occupant usage of the mechanical ventilation systems were monitored for one week in each home. Installed performance is compared to inferred design intent. The paper also includes homeowner perceptions about, and interactions with, the installed mechanical ventilation systems.

Martin, Eric↗

Method and apparatus for reduction of water re-evaporation in a dedicated dehumidifier/water heater

An apparatus that includes a refrigeration circuit that includes an evaporator, a first condenser and a compressor. The apparatus includes a refrigerant-water heat exchanger that includes a second condenser fluidly coupled to the refrigeration circuit. A control valve is operatively connected to the refrigeration circuit to direct flow of refrigerant through at least one of the first condenser during a dehumidification mode and the second condenser during a water heating mode. A damper is disposed on an upwind side of the evaporator, the damper being operable to reduce airflow across the evaporator during a ventilation mode.

Uselton, Robert B.↗

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

High temperature corrosion sensor

A high temperature corrosion sensor is provided having (i) a housing having an external wall and an internal wall, the internal wall of the housing forming a chamber of the housing, (ii) a stainless steel tube inserted into the chamber, (iii) a ceramic tube wherein at least a portion of the ceramic tube is inserted into the stainless steel tube, (iv) an airflow tube that extends through the chamber, and (v) a sensor probe having a first working electrode, a second working electrode, a reference electrode, a positive electrical resistance, a negative electrical resistance, and a thermocouple, wherein at least a portion of each are encapsulated into a ceramic casting that is located at one end of the housing. Methods of measuring corrosion within a power plant environment are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Helical flow filter

A filter includes a filter outer wall, and a filter inner wall spaced apart from the filter outer wall. The filter inner wall and the filter outer wall define a filter void therebetween, and the filter inner wall and the filter outer wall extend along a filter axis. A volume of filtration material is positioned in the filter void, and a plurality of baffles extend between the filter inner wall and the filter outer wall. The plurality of baffles are configured to induce a helical component to an airflow entering the filter void at a first void end relative to the filter axis and exiting the filter void at a second void end opposite the first void end.

Hanson, Thomas David↗

A Data Processing Pipeline for Adversarial Socio-Technical Network Analysis

With the rapid adoption of emerging technologies, there is a need to catalog and model sociotechnical interdependencies that have been historically used to influence the operation of Critical Infrastructure networks including the impacts of mergers and acquisitions, hostile takeovers, and foreign investment. Our research intends to address this need with two primary contributions. First, we have developed a data curation and processing pipeline to generate sociotechnical networks extracted from a variety of data sources including SEC filings and infrastructure asset databases. The pipeline, implemented in Apache Airflow, extracts and normalizes the representation of entities and relations, specified within ontologies. Our intent is to provide an extensible, machine-actionable approach to quickly communicate such models, reproduce previous results, and adapt them to new, unanticipated situations. Second, networks produced by our pipeline enable the development of graph-theoretic metrics that consider the properties of network components in addition to its topology. Metadata associated with network components---whether semantic, temporal, or geospatial---affects the alignment of generated networks with assumptions underlying complexity metrics. Validation of generated networks relative to component types defined by an ontology, may allow the research community to adapt metrics to the semantics of the domains being studied. Generated networks may be processed as knowledge, dynamic, or spatial graphs and enables a variety of analyses including automated reasoning and measures of network complexity. Automated reasoning views extracted entities and relations as a knowledge graph; this enables application of inference rules that represent historically-attested adversarial business methods and applies that behavior to a specific geographic context. Measures of network complexity, including degree distribution, reachability analyses, temporal analysis, and community detection can be adapted to indicate adversarial organizational influence.

97 MATHEMATICS AND COMPUTING↗