Investigation of air-water two-phase flow characteristics in a 25.4 mm diameter circular pipe
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Thermal protection systems are used to protect spacecraft payloads during the extreme conditions of atmospheric entry. The backbone of the composite material often used for NASA mission is carbon fiber, which oxidizes at these conditions. This study presents the direct observation of carbon oxidation using in situ Scanning Transmission Electron Microscopy (STEM). A thin section of a commercially-available carbon fiber material containing multiple structures was examined by STEM in a closed-environmental cell in which temperature was raised from 25 to 1050 °C under a steady flow of air. Results show that the random polycrystalline carbon structure oxidized more uniformly and rapidly than the single crystallite region, which oxidized more anisotropically. These findings are the first to directly observe the structural dependence of carbon oxidation rates at these length-scales while also giving important insight into the onset of pitting at various active surface sites, important pieces in fundamentally understanding of carbon oxidation.
Significant knowledge gaps remain in our understanding of turbulence–cloud–aerosol interactions in the Earth's atmosphere, and direct numerical simulation (DNS) has increasingly become an indispensable tool to fill such critical knowledge gaps. Here, this study is an extension of our previous DNS model [Gao et al., J. Geophys. Res.: Atmos., 123(4), 2194–2214 (2018)], with a focus on the activation of aerosol particles into cloud droplets and deactivation of cloud droplets into aerosol particles in a microscale cloud environment. The effects of turbulence intensity, particle curvature, and solute, as well as the initial distributions of the aerosol particles (monodisperse or polydisperse) are investigated. The governing equations for the flow of air, temperature, and water vapor mixing ratio are solved numerically in the Eulerian fashion, assuming homogeneous and isotropic turbulence. The dynamics of the aerosol and cloud particles are calculated with the Lagrangian particle tracking method. The results show that the deviations of the thermodynamic variables from their respective means are significantly reduced, the activation process appears to be delayed, and the deactivation process occurs more rapidly, as the turbulence intensity is increased. The inclusion of particle curvature and solute effects, as well as polydispersity, tends to retard the activation of aerosols into cloud droplets. It is also observed that fluctuations in supersaturation broaden the spread of particle radii, and the broadening is followed by a narrowing as turbulent homogenization reduces thermodynamic fluctuations over time.
A novel high temperature particle solar receiver is developed by using a light trapping planar cavity configuration. As particles fall through the cavity, the concentrated solar radiation warms the boundaries of the receiver and in turn heats the particles. Particles flow through the system, forming a packed bed at the lower end, leaving the system from the bottom at a constant flow rate. Air is introduced to the system as the fluidizing medium to improve particle heat transfer and mixing. A laboratory scale cavity receiver is built and a near IR quartz lamp is used to provide flux to the vertical wall of the heat exchanger. The system is modeled using a continuum two-fluid method. The computational model matches the experimental system size and the particle size distribution is assumed monodisperse. A conduction model that accounts for the effects of solid concentration is implemented, and the heat flux boundary condition matches the experimental setup. Radiative heat transfer is estimated using a widely used correlation during the post-processing step to determine an overall heat transfer coefficient. The model is validated against testing data and achieves less than 30% discrepancy and a heat transfer coefficient greater than 1000 W/m2K.
Abstract The present study focuses on whether adapting low emissions liquid fuel injection concepts can be applied to gaseous mixtures. The goal is to develop an injector with specific geometric characteristics that will achieve the lowest emissions. This is conducted by evaluating emissions and flame diagnostics on a set of test hardware that has been developed for combustion of pure hydrogen and hydrogen/methane mixtures. The current test hardware adapts lean direct injection concepts from aeroengine injectors to a ground-based engine based on target flows associated with a Solar Turbines Industrial Engine gas turbine. A statistical test plan was developed to assess these geometric characteristics using a three level Box Behnken design. The test plan investigates the effect of injector flow splits, air swirl, fuel swirl, pressure drop, preheat temperature, fuel composition, and the adiabatic flame temperature on the flame structure and emissions performance. A total of 16 injectors were considered for a total of 688 test points for emission and imaging data. Emissions data were reported on a mass basis in ng/J and chemical reactor network analysis were conducted to further interpret emissions behavior. Images were also captured to analyze the flame structure features of interest including reaction volume, flame length, flame spread, and flame width. With these results, a predictive model for emissions was made to conclude the most optimal injector configuration is to have the highest level of air split (more volume of air through the injector plate versus the injector) and air swirl angle for both methane and hydrogen gas mixtures. The predictive emissions level for all of these cases were below 10 ng/J.
Hydrogen or hydrogen blend fuels are expected to replace natural gas in land-based industrial gas turbines (IGTs) to support a greener power economy. Silicon carbide (SiC) base ceramic matrix composites (CMCs) are considered for replacement of Ni-based superalloys to facilitate future efficiency improvements. SiC CMCs require environmental barrier coatings (EBCs) to mitigate volatilization from high-temperature steam, thus making the EBC lifetime critical information for identifying CMC component lifetimes. The goal of this project is to determine the maximum bond coating temperature underneath the EBC for achieving an IGT component lifetime goal of 25,000 h, which is far greater than current CMC component lifetime requirements for aero-turbine applications. To provide data for the lifetime model, laboratory testing used plasma-sprayed rare-earth silicate EBCs on monolithic SiC substrates with an intermediate Si bond coating. Specimens exposed to 1-h thermal cycles in flowing air-steam environments and reaction kinetics were assessed from 700°-1350°C by measuring the thickness of the thermally grown silica scales. The silica growth and phase transformation appear critical in predicting EBC lifetime and several strategies have been explored to reduce the oxide growth rate and improve EBC durability at elevated temperatures. Advanced characterization using Raman spectroscopy has helped clarify this system.
Locomotion of soft robots typically relies on control of multiple inflatable actuators by electronic computers and hard valves. Soft pneumatic oscillators can reduce the demand on controllers by generating complex movements required for locomotion from a single, constant input pressure, but either have been constrained to low rates of flow of air or have required complex fabrication processes. Here, we describe a pneumatic oscillator fabricated from flexible, but inextensible, sheets that provides high rates of airflow for practical locomotion by combining three instabilities: out-of-plane buckling of the sheets, kinking of tubing attached to the sheets, and a system-level instability resulting from connection of an odd number of pneumatic inverters made from these sheets in a loop. This device, which we call a “buckling-sheet ring oscillator” (BRO), directly generates movement from its own interaction with its surroundings and consists only of readily available materials assembled in a simple process—specifically, stacking acetate sheets, nylon film, and double-sided tape, and attaching an elastomeric tube. A device incorporating a BRO is capable of both translational and rotational motion over varied terrain (even without a tether) and can climb upward against gravity and downward against the buoyant force encountered under water.
Three-beam rotational coherent anti-Stokes Raman scattering (CARS) measurements performed in highly scattering environments are susceptible to contamination by two-beam CARS signals generated by the pump–probe and Stokes–probe interactions at the measurement volume. If this occurs, differences in the Raman excitation bandwidth between the two-beam and three-beam CARS signals can add significant errors to the spectral analysis. This interference to the best of our knowledge has not been acknowledged in previous three-beam rotational CARS experiments, but may introduce measurement errors up to 25% depending on the temperature, amount of scattering, and differences between the two-beam and three-beam Raman excitation bandwidths. Here, the presence of two-beam CARS signal contamination was experimentally verified using a femtosecond–picosecond rotational CARS instrument in two scattering environments: (1) a fireball generated by a laboratory-scale explosion that contained particulate matter, metal fragments, and soot, and (2) a flow of air and small liquid droplets. A polarization scheme is presented to overcome this interference. By rotating the pump and Stokes polarizations +55° and –55° from the probe, respectively, the two-beam and three-beam CARS signals are orthogonally polarized and can be separated using a polarization analyzer. Using this polarization arrangement, the Raman-resonant three-beam CARS signal amplitude is reduced by a factor of 2.3 compared to the case where all polarizations are parallel. This method is successfully demonstrated in both scattering environments. A theoretical model is presented, and the temperature measurement error is studied for different experimental conditions. The criteria for when this interference may be present are discussed.
Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.
Abstract. This paper describes the data collected by the University of Nebraska-Lincoln (UNL) as part of the field deployments during the Lower Atmospheric Process Studies at Elevation – a Remotely-piloted Aircraft Team Experiment (LAPSE-RATE) flight campaign in July 2018. The UNL deployed two multirotor unmanned aerial systems (UASs) at multiple sites in the San Luis Valley (Colorado, USA) for data collection to support three science missions: convection initiation, boundary layer transition, and cold air drainage flow. We conducted 172 flights resulting in over 21 h of cumulative flight time. Our novel design for the sensor housing onboard the UAS was employed in these flights to meet the aspiration and shielding requirements of the temperature and humidity sensors and to separate them from the mixed turbulent airflow from the propellers. Data presented in this paper include timestamped temperature and humidity data collected from the sensors, along with the three-dimensional position and velocity of the UAS. Data are quality-controlled and time-synchronized using a zero-order-hold interpolation without additional post-processing. The full dataset is also made available for download at https://doi.org/10.5281/zenodo.4306086 (Islam et al., 2020).
Different thermal analysis models were developed to simulate the dry cask simulator (DCS). The DCS is an experiment designed to simulate dry storage of a single boiling water reactor fuel assembly under a variety of heat loads and internal pressures. The DCS was set up and tested in both a vertical and horizontal configuration to determine cladding temperatures in vertical and horizontal dry cask storage systems. The models included a detailed STAR-CCM+ model with the fuel assembly geometry explicitly modeled, a porous STAR-CCM+ model with the fuel assembly geometry modeled as porous media region with calculated effective properties, and a COBRA-SFS model. COBRA-SFS is a thermal-hydraulic code developed for steady-state and transient analysis of multi assembly spent-fuel storage and transportation systems. STAR-CCM+ is a commercial computation fluid dynamics (CFD) code. Both a detailed and porous STARCCM+ model were developed to look at the effective thermal conductivity (keff) approach to modeling a fuel assembly. A keff fuel model is typically model in CFD thermal analyses due to its significantly lower computational costs. The models were run for a combination of low and high canister pressures (100 kPa and 800 kPa) and low and high internal heat loads (0.5 kW and 5 kW). Results from all three models were compared against experimental data taken from the DCS for the peak cladding temperature (PCT) and inlet air mass flow.
A heat exchanger system includes a heat exchanger coil circulating a first heat transfer fluid therethrough, and a fan at least partially surrounded by the heat exchanger coil to urge a flow of air through the heat exchanger coil to dissipate thermal energy from the first heat transfer fluid. A brushless direct current fan motor is located the fan to urge rotation of the fan and an ancillary electrical component operably connected to the heat exchanger system and electrically isolated from the first heat transfer fluid.
A blade for use in a wind turbine comprises a pressure side and suction side meeting at a trailing edge and leading edge. The pressure side and suction side provide lift to the turbine blade upon the flow of air from the leading edge to the trailing edge and over the pressure side and suction side. The blade includes one or more openings at the suction side, in some cases between the leading edge and the trailing edge. The one or more openings are configured to provide a pressurized fluid towards the leading edge of the blade, in some cases at an angle between about 0° and 70° with respect to an axis oriented from a centerline of the blade toward the leading edge.
An air bearing for calibrating a force measurement device comprises an inner wall, an outer wall, an upper wall, a lower wall, an internal chamber, an object retention opening, and a plurality of air outlets. The inner wall and outer wall each have a cylindrical shape with the outer wall being concentric with the inner wall. The upper wall and lower wall each have an annular shape and are attached to the inner wall and the outer wall. The internal chamber is formed by inner surfaces of the four walls, and is configured to retain compressed air. The object retention opening is formed by an outer surface of the inner wall and is configured to receive and retain an object. The air outlets are positioned along the inner wall and are configured to allow compressed air to flow from the internal chamber to the object retention opening.
Unwanted air leakage and moisture in building envelopes can cause high energy consumption, detrimental indoor air quality, poor occupant comfort, and reduction in building material durability. High moisture can cause rot and mold, leading to costly and time-consuming repairs that add to the carbon burden of the building envelope. Novel detection techniques for locating and measuring air leakage flow and areas of high moisture in building envelopes will be presented. The techniques are easy, fast, and non-destructive which can enable quick building envelope assessment, foster retrofits, and lead to energy savings and carbon emission reduction.
A passenger cabin air distribution system includes a ventilation system and an ejector-diffuser. The ventilation system is operable to provide a conditioned air. The ejector-diffuser is positioned to receive a flow of the conditioned air from the ventilation system. The ejector-diffuser includes an induction unit and a diffuser section. The induction unit includes a secondary inlet in communication with a cabin air from a passenger cabin and is configured to mix the flow of the conditioned air with an induced flow of the cabin air into a mixed air. The diffuser section includes a discharge to eject the mixed air to the passenger cabin. The diffuser section is shaped to provide for efficient mixing with low backpressure in order to maintain the low motive pressure in the nozzle.
Operating a gaseous hydrogen fuel engine includes controlling an injection timing of a gaseous hydrogen fuel injected into a flow of pressurized intake air so as to produce a leading cooling flow of pressurized intake air into a cylinder in an engine, a trailing purging flow through an intake conduit, and a middle flow of both pressurized intake air and gaseous hydrogen fuel into the cylinder. Undesired combustion such as preignition and/or backfire can be limited. Related apparatus and control logic is also disclosed.
Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.