Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Experimental scaling law for mass ablation rate from a Sn plasma generated by a 1064 nm laser

The ablation depth in planar Sn targets irradiated with a pulsed 1064 nm laser was investigated over laser intensities from 3x10{sup 11} to 2x10{sup 12} W/cm{sup 2}. The ablation depth was measured by irradiating a thin layer of Sn evaporated onto a Si wafer, and looking for signatures of Si ions in the expanding plasma with spectroscopic and particle diagnostics. It was found that ablation depth scales with laser intensity to the (5/9)th power, which is consistent with analytical models of steady-state laser ablation, as well as empirical formulae from previous studies of mass ablation rate in overlapping parameter space. In addition, the scaling of mass ablation rate with atomic number of the target as given by empirical formulae in previous studies using targets such as C and Al, are shown to remain valid for the higher atomic number of the target (Z=50) used in these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of the plumes produced by ultrafast laser ablation of metals

We have analyzed ultrafast laser ablation of a metallic target (Nickel) in high vacuum addressing both expansion dynamics of the various plume components (ionic and nanoparticle) and basic properties of the ultrafast laser ablation process. While the ion temporal profile and ion angular distribution were analyzed by means of Langmuir ion probe technique, the angular distribution of the nanoparticulate component was characterized by measuring the thickness map of deposition on a transparent substrate. The amount of ablated material per pulse was found by applying scanning white light interferometry to craters produced on a stationary target. We have also compared the angular distribution of both the ionic and nanoparticle components with the Anisimov model. While the agreement for the ion angular distribution is very good at any laser fluence (from ablation threshold up to {approx_equal}1 J/cm{sup 2}), some discrepancies of nanoparticle plume angular distribution at fluencies above {approx_equal}0.4 J/cm{sup 2} are interpreted in terms of the influence of the pressure exerted by the nascent atomic plasma plume on the initial hydrodynamic evolution of the nanoparticle component. Finally, analyses of the fluence threshold and maximum ablation depth were also carried out, and compared to predictions of theoretical models. Our results indicate that the absorbed energy is spread over a length comparable with the electron diffusion depth L{sub c} ({approx_equal}30 nm) of Ni on the timescale of electron-phonon equilibration and that a logarithmic dependence is well-suited for the description of the variation in the ablation depth on laser fluence in the investigated range.

36 MATERIALS SCIENCE↗

High Current Cathodes Fabricated by KrF Laser Ablation

In this paper we review several high power laser ablation techniques that have been utilized to fabricate high current (1-80 kA) electron beam cathodes for accelerators and microwave sources: 1) Projection Ablation Lithography (PAL) cathodes, 2) Ablation Line Focus (ALF) cathodes, and 3) Metal-Oxide-Junction (MOJ) cathodes. Laser-ablative micromachining techniques (PAL and ALF) have been utilized to generate micron-scale features on metal substrates that provide electric field (beta) enhancement for Fowler-Nordheim emission and plasma cathodes. Since these laser-ablated patterns are directly, laser-written on the substrate metal they exhibit much higher thermal conductivity for higher current capability and increased damage thresholds. Metal-Oxide-Junction (MOJ) cathodes exploit the triple-point electron emission that occurs at the interface between metal, insulator and vacuum.The ablation laser is a KrF excimer laser with a pulse energy of 600 mJ and pulselength of 20 ns. Cathode experiments were performed on the MELBA-C accelerator: V = -300 kV, pulselength = 0.5 microsecond. Data will be presented for PAL, ALF and MOJ cathodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Update On CO{sub 2} Laser Ablation Of Polyoxymethylene At 101 kPa

Recent work has brought about a renewed interest in CO{sub 2} laser ablation studies of polyoxymethylene, due to its potential as a test target for enhancing modern understanding of the laser ablation process. In this paper, new results taken in air at atmosphere pressure are reported, including data measured at institutions in Germany and Japan, which increase the body of literature data on CO{sub 2} laser ablation of polyoxymethylene. The results are discussed in terms of aerospace parameters such as the momentum coupling coefficient and specific impulse, and are compared to a previous literature study. The threshold fluence is specified for ablation of polyoxymethylene by CO{sub 2} laser radiation. Fluences higher (and lower) than previously tested for CO{sub 2} laser ablation were studied herein, and record specific impulse values for CO{sub 2} laser ablation of flat polyoxymethylene are also reported here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling CO{sub 2} Laser Ablative Impulse with Polymers

Laser ablation vaporization models have usually ignored the spatial dependence of the laser beam. Here, we consider effects from modeling using a Gaussian beam for both photochemical and photothermal conditions. The modeling results are compared to experimental and literature data for CO{sub 2} laser ablation of the polymer polyoxymethylene under vacuum, and discussed in terms of the ablated mass areal density and momentum coupling coefficient. Extending the scope of discussion, laser ablative impulse generation research has lacked a cohesive strategy for linking the vaporization and plasma regimes. Existing models, mostly formulated for ultraviolet laser systems or metal targets, appear to be inappropriate or impractical for applications requiring CO{sub 2} laser ablation of polymers. A recently proposed method for linking the vaporization and plasma regimes for analytical modeling is addressed here along with the implications of its use. Key control parameters are considered, along with the major propulsion parameters needed for laser ablation propulsion modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser Ablation of Biological Tissue Using Pulsed CO{sub 2} Laser

Laser scalpels are currently used as a form of laser treatment. However, their ablation mechanism has not been clarified because laser excision of biological tissue occurs over a short time scale. Biological tissue ablation generates sound (laser-induced sound). This study seeks to clarify the ablation mechanism. The state of the gelatin ablation was determined using a high-speed video camera and the power reduction of a He-Ne laser beam. The aim of this study was to clarify the laser ablation mechanism by observing laser excision using the high-speed video camera and monitoring the power reduction of the He-Ne laser beam. We simulated laser excision of a biological tissue by irradiating gelatin (10 wt%) with radiation from a pulsed CO{sub 2} laser (wavelength: 10.6 {mu}m; pulse width: 80 ns). In addition, a microphone was used to measure the laser-induced sound. The first pulse caused ablation particles to be emitted in all directions; these particles were subsequently damped so that they formed a mushroom cloud. Furthermore, water was initially evaporated by laser irradiation and then tissue was ejected.

42 ENGINEERING↗

Preheating ablation effects on the Rayleigh-Taylor instability in the weakly nonlinear regime

The two-dimensional Rayleigh-Taylor instability (RTI) with and without thermal conduction is investigated by numerical simulation in the weakly nonlinear regime. A preheat model {kappa}(T)={kappa}{sub SH}[1+f(T)] is introduced for the thermal conduction [W. H. Ye, W. Y. Zhang, and X. T. He, Phys. Rev. E 65, 057401 (2002)], where {kappa}{sub SH} is the Spitzer-Haerm electron thermal conductivity coefficient and f(T) models the preheating tongue effect in the cold plasma ahead of the ablation front. The preheating ablation effects on the RTI are studied by comparing the RTI with and without thermal conduction with identical density profile relevant to inertial confinement fusion experiments. It is found that the ablation effects strongly influence the mode coupling process, especially with short perturbation wavelength. Overall, the ablation effects stabilize the RTI. First, the linear growth rate is reduced, especially for short perturbation wavelengths and a cutoff wavelength is observed in simulations. Second, the second harmonic generation is reduced for short perturbation wavelengths. Third, the third-order negative feedback to the fundamental mode is strengthened, which plays a stabilization role. Finally, on the contrary, the ablation effects increase the generation of the third harmonic when the perturbation wavelengths are long. Our simulation results indicate that, in the weakly nonlinear regime, the ablation effects are weakened as the perturbation wavelength is increased. Numerical results obtained are in general agreement with the recent weakly nonlinear theories as proposed in [J. Sanz, J. Ramirez, R. Ramis et al., Phys. Rev. Lett. 89, 195002 (2002); J. Garnier, P.-A. Raviart, C. Cherfils-Clerouin et al., Phys. Rev. Lett. 90, 185003 (2003)].

36 MATERIALS SCIENCE↗

Observations of multimode perturbation decay at non-accelerating, soft x-ray driven ablation fronts

Minimizing the growth of hydrodynamic instabilities is a fundamental design issue facing the achievement of thermonuclear ignition and burn with Inertial Confinement Fusion (ICF). The thin capsules and extreme accelerations found in ICF make it an inherently unstable system primarily to Rayleigh-Taylor (RT) occurring at the ablation front. A potential mechanism by which perturbations at the outer capsule surface can be reduced lies in the already present ablative Richtmyer-Meshkov (RM) effect, which operates during the first shock transit of the ablator. At present, the available Equation of State (EOS) models predict a wide range of behavior for the ablative RM oscillations of multimode isolated defects on plastic (CH) capsules. To resolve these differences, we conducted experiments at the OMEGA Laser Facility [T. R. Boehly et al., Optics Comm. 133 (1997)] that measured the evolution of gaussian-shaped bumps driven by soft x-ray ablation from a halfraum. Shock speeds in the CH target were measured to reach 15 {mu}m/ns for halfraum radiation temperatures of 70 eV lasting for up to 7 ns. The evolution of gaussian-shaped bumps of different widths and heights were measured using on-axis x-ray radiography at up to 37 Multiplication-Sign magnification. Bumps with initial widths of 34 and 44 {mu}m FWHM were found to grow by 3 Multiplication-Sign their initial areal density and then saturate out to 6 ns due to lateral compression of the bump characteristic of the formation of a rippled shock front propagating into the solid target. Narrower 17 {mu}m FWHM bumps, on the other hand, grew by roughly 2 Multiplication-Sign followed immediately by a decrease back to initial values of areal density out to 7 ns, which largely agrees with both LEOS 5310 and SESAME 7592 EOS predictions. The difference in observed behavior suggests that high spatial frequency modes found in narrower bumps are needed to significantly affect the ablation front profile on shorter time scales.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Doping He droplets by laser ablation with a pulsed supersonic jet source

Laser ablation offers the possibility to study a rich number of atoms, molecules, and clusters in the gas phase. By attaching laser ablated materials to helium nanodroplets, one can gain highly resolved spectra of isolated species in a cold, weakly perturbed system. Here, we present a new setup for doping pulsed helium nanodroplet beams by means of laser ablation. In comparison to more well-established techniques using a continuous nozzle, pulsed nozzles show significant differences in the doping efficiency depending on certain experimental parameters (e.g., position of the ablation plume with respect to the droplet formation, nozzle design, and expansion conditions). In particular, we demonstrate that when the ablation region overlaps with the droplet formation region, one also creates a supersonic beam of helium atoms seeded with the sample material. The processes are characterized using a surface ionization detector. The overall doping signal is compared to that of conventional oven cell doping showing very similar dependence on helium stagnation conditions, indicating a comparable doping process. Finally, the ablated material was spectroscopically studied via laser induced fluorescence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulsed laser ablation of binary semiconductors: mechanisms of vaporisation and cluster formation

Formation of small clusters during pulsed ablation of two binary semiconductors, zinc oxide and indium phosphide, in vacuum by UV, visible, and IR laser radiation is comparatively studied. The irradiation conditions favourable for generation of neutral and charged Zn{sub n}O{sub m} and In{sub n}P{sub m} clusters of different stoichiometry in the ablation products are found. The size and composition of the clusters, their expansion dynamics and reactivity are analysed by time-of-flight mass spectrometry. A particular attention is paid to the mechanisms of ZnO and InP ablation as a function of laser fluence, with the use of different ablation models. It is established that ZnO evapourates congruently in a wide range of irradiation conditions, while InP ablation leads to enrichment of the target surface with indium. It is shown that this radically different character of semiconductor ablation determines the composition of the nanostructures formed: zinc oxide clusters are mainly stoichiometric, whereas In{sub n}P{sub m} particles are significantly enriched with indium. (photonics and nanotechnology)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultrashort-pulse laser ablation of nanocrystalline aluminum

Molecular-dynamics simulations of the ablation of nanocrystalline Al films by ultrashort laser pulses in the low-fluence (no-ionization) regime (0-2.5 times the ablation threshold, F{sub th}) are reported. The simulations employ an embedded-atom method potential for the dynamics of the ions and a realistic two-temperature model for the electron gas (and its interactions with the ion gas), which confers different electronic properties to the monocrystalline solid, nanocrystalline solid, and liquid regions of the targets. The ablation dynamics in three nanocrystalline structures is studied: two dense targets with different crystallite sizes (d=3.1 and 6.2 nm on average) and a d=6.2 nm porous sample. The results are compared to the ablation of monocrystalline Al. Significant differences are observed, the nanocrystalline targets showing, in particular, a lower ablation threshold and a larger melting depth, and yielding pressure waves of higher amplitude than the monocrystalline targets. Furthermore, it is shown that nanocrystalline targets experience no residual stress associated with thermal expansion and lateral constraints, and that little crystal growth occurs in the solid during and after ablation. Laser-induced spallation of the back surface of the films is also investigated; we find, in particular, that the high-strain fracture resistance of nanocrystalline samples is significantly reduced in comparison to the crystalline material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-critical phase explosion promoting breakdown plasma ignition during laser ablation of graphite

Removal rate, air shock, and ablative recoil pressure parameters were measured as a function of laser intensity I{sub peak} during nanosecond laser ablation of graphite. Surface vaporization of molten graphite at low intensities I{sub peak}<0.15 GW/cm{sup 2} was observed to transform into its near-critical phase explosion (intense homogeneous boiling) at the threshold intensity I{sub PE}approx =0.15 GW/cm{sup 2} in the form of a drastic, correlated rise of removal rate, air shock, and ablative recoil pressure magnitudes. Just above this threshold (I{sub peak}>=0.25 GW/cm{sup 2}), the explosive mass removal ended up with saturation of the removal rate, much slower increase of the air and recoil pressure magnitudes, and appearance of a visible surface plasma spark. In this regime, the measured far-field air shock pressure amplitude exhibits a sublinear dependence on laser intensity (propor toI{sub peak}{sup 4/9}), while the source plasma shock pressure demonstrates a sublinear trend (propor toI{sub peak}{sup 3/4}), both indicating the subcritical character of the plasma. Against expectations, in this regime the plasma recoil pressure increases versus I{sub peak} superlinearly (propor toI{sub peak}{sup 1.1}), rather than sublinearly (propor toI{sub peak}{sup 3/4}), with the mentioned difference related to the intensity-dependent initial spatial plasma dimensions within the laser waist on the graphite surface and to the plasma formation time during the heating laser pulse (overall, the pressure source effect). The strict coincidence of the phase explosion, providing high (kbar) hydrodynamic pressures of ablation products, and the ignition of ablative laser plasma in the carbon plume may indicate the ablative pressure-dependent character of the underlying optical breakdown at the high plume pressures, initiating the plasma formation. The experimental data evidence that the spatiotemporal extension of the plasma in the laser plume and ambient air during the heating laser pulse is supported by fast lateral electron and radiative heat conduction (laser-supported combustion wave regime), rather than by propagation of a strong shock wave (laser-supported detonation wave regime).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed laser ablation of dental calculus in the near ultraviolet

Pulsed lasers emitting wavelengths near 400 nm can selectively ablate dental calculus without damaging underlying and surrounding sound dental hard tissue. Our results indicate that calculus ablation at this wavelength relies on the absorption of porphyrins endogenous to oral bacteria commonly found in calculus. Sub- and supragingival calculus on extracted human teeth, irradiated with 400-nm, 60-ns laser pulses at ≤8 J/cm2, exhibits a photobleached surface layer. Blue-light microscopy indicates this layer highly scatters 400-nm photons, whereas fluorescence spectroscopy indicates that bacterial porphyrins are permanently photobleached. A modified blow-off model for ablation is proposed that is based upon these observations and also reproduces our calculus ablation rates measured from laser profilometry. Tissue scattering and a stratified layering of absorbers within the calculus medium explain the gradual decrease in ablation rate from successive pulses. Depending on the calculus thickness, ablation stalling may occur at <5 J/cm2 but has not been observed above this fluence.

47 OTHER INSTRUMENTATION↗

Thermal melting and ablation of silicon by femtosecond laser radiation

The space-time dynamics of thermal melting, subsurface cavitation, spallative ablation, and fragmentation ablation of the silicon surface excited by single IR femtosecond laser pulses is studied by timeresolved optical reflection microscopy. This dynamics is revealed by monitoring picosecond and (sub)nanosecond oscillations of probe pulse reflection, which is modulated by picosecond acoustic reverberations in the dynamically growing surface melt subjected to ablation and having another acoustic impedance, and by optical interference between the probe pulse replicas reflected by the spalled layer surface and the layer retained on the target surface. The acoustic reverberation periods change during the growth and ablation of the surface melt film, which makes it possible to quantitatively estimate the contributions of these processes to the thermal dynamics of the material surface. The results on the thermal dynamics of laser excitation are supported by dynamic measurements of the ablation parameters using noncontact ultrasonic diagnostics, scanning electron microscopy, atomic force microscopy, and optical interference microscopy of the modified regions appearing on the silicon surface after ablation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Safety and Efficacy of Oxycodone Versus Fentanyl in Percutaneous Microwave Ablation of a Liver Tumour Abutting the Capsule

Purpose: The present study compared the safety and efficacy of oxycodone with those of fentanyl under non-intubated general anaesthesia in percutaneous microwave ablation (MWA) of a liver tumour abutting the capsule. Materials and Methods: Thirty-eight patients underwent MWA of liver cancers abutting the capsule. Patients received 0.1 mg/kg oxycodone (O group) or 1 μg/kg fentanyl (F group) prior to the start of ablation. Both groups received continuous infusions of propofol for non-intubated general anaesthesia during ablation. The primary outcomes were the pain scores (11-point numeric rating scale, NRS) within 24 h after MWA. Vital signs, body movement during ablation, and opioid side effects after ablation were recorded. The need for additional analgesics was recorded 24 h after MWA. Results: The pain NRS scores were lower in the O group than in the F group at 0.5 (P = 0.035), 3 (P = 0.002), and 6 h (P = 0.001) after MWA, and fewer patients required additional analgesics in the O group (6 of 20 vs. 13 of 18, P = 0.022) within 24 h. The average 24-h dose of dezocine was 5.5 ± 4.1 mg in the F group and 2.1 ± 3.3 mg in the O group (P = 0.008). A significant reduction in the respiratory rate (P = 0.020) and more body movements were observed in the F group (P = 0.027) during ablation with non-intubated general anaesthesia. No differences in post-operative nausea and vomiting (PONV) were observed between the two groups, but dizziness occurred significantly more often in the O group (P = 0.033). No significant differences in other vital signs were observed before, during, and after the procedure. Conclusions: Oxycodone provides better analgesia and reduces post-operative opioid consumption without significant respiratory or hemodynamic instability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time US-{sup 18}FDG-PET/CT Image Fusion for Guidance of Thermal Ablation of {sup 18}FDG-PET-Positive Liver Metastases: The Added Value of Contrast Enhancement

Purpose: To assess the feasibility of US-{sup 18}FDG-PET/CT fusion-guided microwave ablation of liver metastases either poorly visible or totally undetectable with US, CEUS and CT, but visualized by PET imaging. Materials and Methods: Twenty-three patients with 58 liver metastases underwent microwave ablation guided by image fusion system that combines US with {sup 18}FDG-PET/CT images. In 28/58 tumors, {sup 18}FDG-PET/CT with contrast medium (PET/CECT) was used. The registration technical feasibility, registration time, rates of correct targeting, technical success at 24 h, final result at 1 year and complications were analyzed and compared between the PET/CT and PET/CECT groups. Results: Registration was successfully performed in all cases with a mean time of 7.8 + 1.7 min (mean + standard deviation), (4.6 + 1.5 min for PET/CECT group versus 10.9 + 1.8 min for PET/CT group, P < 0.01). In total, 46/58 (79.3%) tumors were correctly targeted, while 3/28 (10.7%) and 9/30 (30%) were incorrectly targeted in PET/CT and PET/CECT group, respectively (P < 0.05). Complete ablation was obtained at 24 h in 70.0% of cases (n = 40 tumors), 23/28 (82.1%) in the PET/CECT group and 17/30 (56.7%) in the PET/CT group (P < 0.037). Fourteen tumors underwent local retreatment (11 ablations, 2 with resection and 1 with stereotactic body radiation therapy), while 4 tumors could not be retreated because of distant disease progression and underwent systemic therapy. Finally, 54/58 (93.1%) tumors were completely treated at 1 year. One major complication occurred, a gastrointestinal hemorrhage which required surgical repair. Conclusions: Percutaneous ablation of {sup 18}FDG-PET-positive liver metastases using fusion imaging of real-time US and pre-acquired {sup 18}FDG-PET/CT images is feasible, safe and effective. Contrast-enhanced PET/CT improves overall ablation accuracy and shortens procedural duration time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Accumulation and Effects of Liposomal Doxorubicin in Tissues Treated by Radiofrequency Ablation and Irreversible Electroporation in Liver: In Vivo Experimental Study on Porcine Models

Purpose: To compare the accumulation and effect of liposomal doxorubicin in liver tissue treated by radiofrequency ablation (RFA) and irreversible electroporation (IRE) in in vivo porcine models. Materials and Methods: Sixteen RFA and 16 IRE procedures were performed in healthy liver of two groups of three pigs. Multi-tined RFA parameters included: 100 W, target temperature 105°C for 7 min. 100 IRE pulses were delivered using two monopolar electrodes at 2250 V, 1 Hz, for 100 µsec. For each group, two pigs received 50 mg liposomal doxorubicin (0.5 mg/kg) as a drip infusion during ablation procedure, with one pig serving as control. Samples were harvested from the central and peripheral zones of the ablation at 24 and 72 h. Immunohistochemical analysis to evaluate the degree of cellular stress, DNA damage, and degree of apoptosis was performed. These and the ablation sizes were compared. Doxorubicin concentrations were also analyzed using fluorescence photometry of homogenized tissue. Results: RFA treatment zones created with concomitant administration of doxorubicin at 24 h were significantly larger than controls (2.5 ± 0.3 cm vs. 2.2 ± 0.2 cm; p = 0.04). By contrast, IRE treatment zones were negatively influenced by chemotherapy (2.2 ± 0.4 cm vs. 2.6 ± 0.4 cm; p = 0.05). At 24 h, doxorubicin concentrations in peripheral and central zones of RFA were significantly increased in comparison with untreated parenchyma (0.431 ± 0.078 µg/g and 0.314 ± 0.055 µg/g vs. 0.18 ± 0.012 µg/g; p < 0.05). Doxorubicin concentrations in IRE zones were not significantly different from untreated liver (0.191 ± 0.049 µg/g and 0.210 ± 0.049 µg/g vs. 0.18 ± 0.012 µg/g). Conclusions: Whereas there is an increased accumulation of periprocedural doxorubicin and an associated increase in ablation zone following RFA, a contrary effect is noted with IRE. These discrepant findings suggest that different mechanisms and synergies will need to be considered in order to select optimal adjuvants for different classes of ablation devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomistic modeling of nanoparticle generation in short pulse laser ablation of thin metal films in water

Laser ablation in liquids is actively used for generation of clean colloidal nanoparticles with unique shapes and functionalities. The fundamental mechanisms of the laser ablation in liquids and the key processes that control the nanoparticle structure, composition, and size distribution, however, are not yet fully understood. In this paper, we report the results of first atomistic simulations of laser ablation of metal targets in liquid environment. A model combining a coarse-grained representation of the liquid environment (parameterized for water), a fully atomistic description of laser interactions with metal targets, and acoustic impedance matching boundary conditions is developed and applied for simulation of laser ablation of a thin silver film deposited on a silica substrate. The simulations, performed at two laser fluences in the regime of phase explosion, predict a rapid deceleration of the ejected ablation plume and the formation of a dense superheated molten layer at the water-plume interface. The water in contact with the hot metal layer is brought to the supercritical state and transforms into an expanding low density metal-water mixing region that serves as a precursor for the formation of a cavitation bubble. Two distinct mechanisms of the nanoparticle formation are predicted in the simulations: (1) the nucleation and growth of small (mostly ≤10nm) nanoparticles in the metal-water mixing region and (2) the formation of larger (tens of nm) nanoparticles through the breakup of the superheated molten metal layer triggered by the emergence of complex morphological features attributed to the Rayleigh-Taylor instability of the interface between at the superheated metal layer and the supercritical water. The first mechanism is facilitated by the rapid cooling of the growing nanoparticles in the supercritical water environment, resulting in solidification of the nanoparticles located in the upper part of the mixing region on the timescale of nanoseconds. The computational prediction of the two mechanisms of nanoparticle formation yielding nanoparticles with different characteristic sizes is consistent with experimental observations of two distinct nanoparticle populations appearing at different stages of the ablation process.

Chemistry↗