Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3d”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Comparison of Three-Dimensional (3D) Conformal Proton Radiotherapy (RT), 3D Conformal Photon RT, and Intensity-Modulated RT for Retroperitoneal and Intra-Abdominal Sarcomas

Purpose: To compare three-dimensional conformal proton radiotherapy (3DCPT), intensity-modulated photon radiotherapy (IMRT), and 3D conformal photon radiotherapy (3DCRT) to predict the optimal RT technique for retroperitoneal sarcomas. Methods and Materials: 3DCRT, IMRT, and 3DCPT plans were created for treating eight patients with retroperitoneal or intra-abdominal sarcomas. The clinical target volume (CTV) included the gross tumor plus a 2-cm margin, limited by bone and intact fascial planes. For photon plans, the planning target volume (PTV) included a uniform expansion of 5 mm. For the proton plans, the PTV was nonuniform and beam-specific. The prescription dose was 50.4 Gy/Cobalt gray equivalent CGE. Plans were normalized so that >95% of the CTV received 100% of the dose. Results: The CTV was covered adequately by all techniques. The median conformity index was 0.69 for 3DCPT, 0.75 for IMRT, and 0.51 for 3DCRT. The median inhomogeneity coefficient was 0.062 for 3DCPT, 0.066 for IMRT, and 0.073 for 3DCRT. The bowel median volume receiving 15 Gy (V15) was 16.4% for 3DCPT, 52.2% for IMRT, and 66.1% for 3DCRT. The bowel median V45 was 6.3% for 3DCPT, 4.7% for IMRT, and 15.6% for 3DCRT. The median ipsilateral mean kidney dose was 22.5 CGE for 3DCPT, 34.1 Gy for IMRT, and 37.8 Gy for 3DCRT. The median contralateral mean kidney dose was 0 CGE for 3DCPT, 6.4 Gy for IMRT, and 11 Gy for 3DCRT. The median contralateral kidney V5 was 0% for 3DCPT, 49.9% for IMRT, and 99.7% for 3DCRT. Regardless of technique, the median mean liver dose was <30 Gy, and the median cord V50 was 0%. The median integral dose was 126 J for 3DCPT, 400 J for IMRT, and 432 J for 3DCRT. Conclusions: IMRT and 3DCPT result in plans that are more conformal and homogenous than 3DCRT. Based on Quantitative Analysis of Normal Tissue Effects in Clinic benchmarks, the dosimetric advantage of proton therapy may be less gastrointestinal and genitourinary toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural integrity--Searching the key factor to suppress the voltage fade of Li-rich layered cathode materials through 3D X-ray imaging and spectroscopy techniques

Li-rich layered materials are important cathode compounds used in commercial lithium ion batteries, which, however, suffers from some drawbacks including the so-called voltage fade upon electrochemical cycling. Here, our study employs novel transmission X-ray microscopy to investigate the electrochemical reaction induced morphological and chemical changes in the Li-rich Li 2 Ru 0.5 Mn 0.5 O 3 cathode particles at the meso to nano scale. We performed combined X-ray spectroscopy, diffraction and microscopy experiments to systematically study this cathode material's evolution upon cycling as well as to establish a comprehensive understanding of the structural origin of capacity fade through 2D and 3D fine length scale morphology and heterogeneity change of this material. This work suggests that atomic manipulation (e.g. doping, substitution etc.) or nano engineering (e.g. nano-sizing, heterogeneous structure) are important strategies to mitigate the internal strain and defects induced by extensive lithium insertion/extraction. It also shows that maintaining the structural integrity is the key in designing and synthesizing lithium-rich layered materials with better cycle stability.

25 ENERGY STORAGE↗

A competition between 2D and 3D magnetic orderings in novel mixed valent copper frameworks

Low-dimensional hybrid inorganic–organic frameworks exhibit high structural flexibility and allow for the inclusion of various magnetic and optically-active species into their host structures. The emergence of copper-based hybrid structures for various optical applications provides a promising foundation for exploring the integration of magnetic sublattices, paving the way for advancements in magneto-optical coupling and multifunctional materials. Herein, we introduce a novel class of hybrid copper frameworks with covalently-connected alternating magnetic 2D copper(II) formate and non-magnetic copper(I) bromide layers. The anionic framework is stabilized by A + cations to form ACu 5 Br 4 (COOH) 4 (A + = Na + , K + , Rb + , NH 4 + ) semiconductors (bandgaps 2.1–2.2 eV) with optical transitions suitable for optoelectronic applications. Comprehensive magnetometry studies show that ACu 5 Br 4 (COOH) 4 compounds exhibit low-dimensional 2D short-range antiferromagnetic order within the formate layers, characterized by strong exchange coupling (J/k B ∼ −100 K). Upon further temperature reduction, interactions between Cu(II) layers give rise to 3D long-range magnetic order at ∼40 K, despite the large (8.6–8.8 Å) spatial separation of the magnetic Cu(II) formate layers by nonmagnetic Cu(I)–Br bridging layers. This transition is further supported by electron paramagnetic resonance (EPR) spectroscopy. In conclusion, this study expands our understanding of low-dimensional hybrid frameworks and opens new avenues for the design of 2D multifunctional materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Clusters, molecular layers, and 3D crystals of water on Ni(111)

We examined the growth and stability of ice layers on Ni(111) up to ∼7 molecular layers (ML) thick using scanning tunneling microscopy. At low coverage, films were comprised of ∼1 nm wide two-dimensional (2D) clusters. Only above ∼0.5 ML did patches of continuous 2D layers emerge, coexisting with the clusters until the first ML was complete. The structure of the continuous layer is clearly different from that of the 2D clusters. Subsequently, a second molecular layer grew on top of the first. 3D crystallites started to form only after this 2nd ML was complete. 2D clusters re-appeared when thicker films were partially evaporated, implying that these clusters represent the equilibrium configuration at low coverage. Binding energies and image simulations computed with density functional theory suggest that the 2D clusters are partially dissociated and surrounded by H adatoms. The complete 2D layer contains only intact water molecules because of the lack of favorable binding sites for H atoms. We propose molecular structures for the 2D layer that are composed of the same pentagon-heptagon binding motif and water density observed on Pt(111). The similarity of the water structures on Pt and Ni suggests a general prescription for generating low-energy configurations on close-packed metal substrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of plasma response on plasma displacements in DIII-D during application of external 3D perturbations

The effects of applied non-axisymmetric resonant magnetic perturbations (RMPs) are predicted without and with self-consistent plasma response by modeling of the magnetic field structure and two-fluid MHD simulations, respectively. A synthetic diagnostic is used to simulate soft X-ray (SXR) emission within the steep gradient region of the pedestal, 0.98 > ψ > 0.94. The entire pedestal and edge region is characterized by large changes in plasma rotation and current density. Those parameters are expected to strongly affect the plasma response to RMPs. The M3D-C1 code takes into account this response self-consistently. The plasma response is investigated in detail and used in the forward modeling of the simulated local SXR emission, within the framework of the synthetic diagnostic. The resulting synthetic emission is compared to measured SXR data. The latter clearly shows helical m = 11 ± 1 displacements around the 11/3 rational surface of sizes up to 5 cm, which change with the poloidal angle. The synthetic emission with plasma response is used to explain the nature of the measured displacements. Different approaches are tested. One approach is based on the magnetic field structure to simulate local emission, which shows additional structures at the separatrix, that are caused by the lobes. Especially without plasma response, almost only separatrix structures are generated while no significant displacements are found further inside. Another approach to model local emission uses the fluid quantities electron density and temperature, as calculated by M3D-C1. Compared to the previous approach, based on the magnetic field structure, the emission simulated by the fluid approach with plasma response shows better agreement with the measured SXR data. To be specific, it has comparable displacements in the steep gradient region and no lobe structures at all. The helical displacements around the 11/3 surface are identified to be directly related to the kink response, caused by non-resonant amplification of various poloidal RMP modes due to plasma response. Regarding the latter, the role of different plasma parameters is investigated, but it appears that the electron rotation plays a key role in the formation of screening and resonant amplification, while the kinking appears to be sensitive to the edge current density. As a result, it is also hypothesised that the strength of the kink response is also correlated to edge-localized-mode (ELM) stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3d N=8 Lorentzian Bagger-Lambert-Gustavsson theory as a scaling limit of 3d superconformal N=6 Aharony-Bergman-Jafferis-Maldacena theory

We elaborate on the suggestion made in arXiv:0806.3498 that the 3d N=8 superconformal SU(N) Chern-Simons-matter theory of 'Lorentzian' Bagger-Lambert-Gustavson type (L-BLG) can be obtained by a scaling limit (involving sending the level k to infinity and redefining the fields) from the N=6 superconformal U(N)xU(N) Chern-Simons-matter theory of Aharony, Bergman, Jafferis, and Maldacena (ABJM). We show that to implement such limit in a consistent way one is to extend the ABJM theory by an Abelian 'ghost' multiplet. The corresponding limit at the 3-algebra level also requires extending the nonantisymmetric Bagger-Lambert 3-algebra underlying the ABJM theory by a negative-norm generator. We draw analogy with similar scaling limits discussed previously for bosonic Chern-Simons theory and comment on some implications of this relation between the ABJM and L-BLG theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-AB-BRB-00: Session in Memory of Robert J. Shalek: High Resolution Dosimetry from 2D to 3D to Real-Time 3D

Despite widespread IMRT treatments at modern radiation therapy clinics, precise dosimetric commissioning of an IMRT system remains a challenge. In the most recent report from the Radiological Physics Center (RPC), nearly 20% of institutions failed an end-to-end test with an anthropomorphic head and neck phantom, a test that has rather lenient dose difference and distance-to-agreement criteria of 7% and 4 mm. The RPC report provides strong evidence that IMRT implementation is prone to error and that improved quality assurance tools are required. At the heart of radiation therapy dosimetry is the multidimensional dosimeter. However, due to the limited availability of water-equivalent dosimetry materials, research and development in this important field is challenging. In this session, we will review a few dosimeter developments that are either in the laboratory phase or in the pre-commercialization phase. 1) Radiochromic plastic. Novel formulations exhibit light absorbing optical contrast with very little scatter, enabling faster, broad beam optical CT design. 2) Storage phosphor. After irradiation, the dosimetry panels will be read out using a dedicated 2D scanning apparatus in a non-invasive, electro-optic manner and immediately restored for further use. 3) Liquid scintillator. Scintillators convert the energy from x-rays and proton beams into visible light, which can be recorded with a scientific camera (CCD or CMOS) from multiple angles. The 3D shape of the dose distribution can then be reconstructed. 4) Cherenkov emission imaging. Gated intensified imaging allows video-rate passive detection of Cherenkov emission during radiation therapy with the room lights on. Learning Objectives: To understand the physics of a variety of dosimetry techniques based upon optical imaging To investigate the strategies to overcome respective challenges and limitations To explore novel ideas of dosimeter design Supported in part by NIH Grants R01CA148853, R01CA182450, R01CA109558. Brian Pogue is founder and president of the company DoseOptics LLC, dedicated to developing and commercializing the first dedicated Cerenkov imaging camera and system for radiation dose imaging. Work reported in this talk does not involve the use of DoseOptics technology.; H. Li, this work was supported in part by NIH Grant No. R01CA148853; S. Beddar, NIH funding R01-CA182450.

60 APPLIED LIFE SCIENCES↗

A 3D extra-large-pore zeolite enabled by 1D-to-3D topotactic condensation of a chain silicate

Zeolites are microporous silicates with a large variety of applications as catalysts, adsorbents, and cation exchangers. Stable silica-based zeolites with increased porosity are in demand to allow adsorption and processing of large molecules but challenge our synthetic ability. We report a new, highly stable pure silica zeolite called ZEO-3, which has a multidimensional, interconnected system of extra-large pores open through windows made by 16 and 14 silicate tetrahedra, the least dense polymorph of silica known so far. This zeolite was formed by an unprecedented one-dimensional to three-dimensional (1D-to-3D) topotactic condensation of a chain silicate. With a specific surface area of more than 1000 square meters per gram, ZEO-3 showed a high performance for volatile organic compound abatement and recovery compared with other zeolites and metal-organic frameworks.

Science & Technology - Other Topics↗

Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer

Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

47 OTHER INSTRUMENTATION↗

3D Geologic Framework Modelling of the Los Alamos National Laboratory Site and Pajarito Plateau: Integrating a realistic 3D fault network and modelling subsurface relationships in a sparsely sampled and complex geologic region

The subsurface geology beneath the Pajarito Plateau is critical to understanding the seismic hazard of the Pajarito Fault System, yet our understanding of this geology is relatively poor. While previous 3D geologic framework models of the area have been created for the purposes of understanding hydrogeologic flow, they are inadequate for the purposes of understanding the Pajarito Fault System. The specific challenges of using oil and gas software for this purpose include: (1) the geologic complexities resulting from volcanism and tectonism; (2) a need for a high level of stratigraphic detail over a large area; (3) a near complete lack of seismic data; and (4) sparse wellbore data. Presented here is a workflow that handles these challenges of adapting commercially available software used by the oil and gas industries to this seismic hazard problem.

58 GEOSCIENCES↗

3D printed micro channel plate, method of making and using 3D printed micro channel plate

The invention provides a gain device having a plurality of channels having a polygonal shape with four or more sides. The invention also provides a method for producing microchannel plates (MCPs) having the steps of providing a pre-polymer; and directing a laser over the pre-polymer into a pre-determined pattern. Also provided is method for efficiently 3D printing an object.

42 ENGINEERING↗

3D printed micro channel plate, method of making and using 3D printed micro channel plate

The invention provides a gain device having a plurality of channels having a polygonal shape with four or more sides. The invention also provides a method for producing microchannel plates (MCPs) having the steps of providing a pre-polymer; and directing a laser over the pre-polymer into a pre-determined pattern. Also provided is method for efficiently 3D printing an object.

36 MATERIALS SCIENCE↗