At least 181 records · Page 10

Space Suit Performance: Methods for Changing the Quality of Quantitative Data

NASA is currently designing a new space suit capable of working in deep space and on Mars. Designing a suit is very difficult and often requires trade‐offs between performance, cost, mass, and system complexity. To verify that new suits will enable astronauts to perform to their maximum capacity, prototype suits must be built and tested with human subjects. However, engineers and flight surgeons often have difficulty understanding and applying traditional representations of human data without training. To overcome these challenges, NASA is developing modern simulation and analysis techniques that focus on 3D visualization. Early understanding of actual performance early on in the design cycle is extremely advantageous to increase performance capabilities, reduce the risk of injury, and reduce costs. The primary objective of this project was to test modern simulation and analysis techniques for evaluating the performance of a human operating in extra‐vehicular space suits.

Cowley, Matthew↗

A Jupyter Notebook Environment For Multibody Dynamics

DARTS is a rigid/flexible multibody dynamics toolkit for themodeling and simulation of aerospace and robotic vehicles forengineering applications. In this paper we describe an on-line,browser-based environment using Jupyter notebooks to supporttraining needs for the DARTS software. The suite of curated tutorial notebooks is organized into different topic areas, and intomultiple themes within each topic area. The notebooks within atheme use a progression of examples for users to expand theirunderstanding of the software. The topic areas include one onthe DARTS multibody dynamics software and another one on thetheory underlying the multibody dynamics formulation. We alsodescribe a number of Jupyter extensions that were used - andsome developed in house - to enhance the notebook interface foruse with the dynamics simulation software. One significant extension we implemented allows the embedding of live 3D visualizations within simulation notebooks.

Gaut, Aaron↗

Comparing Human Input in RViz and Virtual Reality Interfaces for 3D Object Manipulation Tasks

Effective human-in-the-loop robot control requires intuitive and easy to use interfaces. We present a within-subjects user study design to compare the ease of use of interfaces for human-robot teleoperation, specifically the ROS 3D visualization tool RViz and a virtual reality interface. Our proposed study will determine which interface is easiest to use and minimizes operator cognitive load in shared autonomy tasks.

Emily Sheetz↗

Application of Digital Image Correlation in Wind Tunnel

Digital image correlation (DIC) is a non-contact measurement technique that has been used in various applications in multiple industries, from microscopic specimens all the way to large scale structures. This project involved using DIC to capture wing deflection under simulated wind loading at various angles of attack (AoA). A subscale model of a fixed-wing aircraft, shown in Figure 1, was used in the 14-footby 22-footsubsonicwind tunnel at the NASA Langley Research Center. The setup used two pairs of cameras mounted on the ceiling of the tunnel to view the starboard and port side wings. Aluminum framing was used to rigidly mount the cameras to beams in the ceiling. Camera setup challenges due to the confined space included obtaining even lighting and working around infrared (IR) cameras that were used to capture the flow over the wing. Remote connection was used to access data acquisition computers from computers in the control room. Eight measurement locations on each wing were made of 1-inch-diametercircular silver dry transfer decals that did not alter the air flow across the wing. These circles were speckled with a black ink pen and were used for the IR camera as well as for DIC systems. A mock setup outside the wind tunnel was used to optimize the camera setup and verify that the speckled tape provided sufficient correlation. DIC was used to track the position of seven locations as the AoA of the subscale model changed from −10 degrees to +10 degrees in 1-degree increments. The model was rotated at a fixed height about the center of the fuselage from −7 degrees to +10 degrees. The height of the model had to be lowered to achieve AoA slower than −7degrees due to geometric constraints of the cart supporting the model and the wind tunnel. The source of light was stationary relative to the model, so the exposure time had to be adjusted for different wing regions and AoA values. The three-dimensional (3D) visualization of the markings and the two-dimensional (2D) projection of these points onto the port wing at 0-degree AoA is shown in Figure 2.

Matlock Mennu↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

EGS Collab Earth Modeling: Integrated 3D Model of the Testbed

The EGS Collab project is conducting a series of stimulation and interwell flow tests in an intermediate scale (~10-20 m) testbed located on the 4850 level in the Sanford Underground Research Facility (SURF) in Lead, South Dakota. The testbed consists of eight ~200 ft (~60 m) HQ-diameter (9.6 cm) boreholes that are drilled into the Poorman Formation from the western rib of the West Access Drift. Of the eight boreholes, one borehole is used as an injection/stimulation well, another sub-parallel borehole located about 10 m away from the injection well is used as a production well, and rest of the other boreholes are used as monitoring wells. For 3D visualization of the testbed as well as to provide spatially accurate and consistent parameter data for geomechanical and geophysical process modeling tasks, we are using Leapfrog Software (Seequent Limited). For analysis of fractures and creation of conditioned stochastic discrete fracture network (CS-DFN) model of the testbed, we are using FracMan (Golder Associates Inc.). As of mid-May 2019, the EGS Collab Leapfrog database contains the general layout of the drifts/shafts at the 4850 and 4100 levels; generalized geologic framework model of a domain that spans both the 4850 and 4100 levels; the CS-DFN of the testbed; and layouts of the EGS Collab testbed boreholes, kISMET testbed boreholes, and other existing boreholes at the 4850 level. This information has been obtained from the SURF Vulcan database, detailed laser scan and point surveys of borehole collar locations, directional surveys of borehole trajectories, and mapping of features in the drifts, boreholes, and cores. Similarly, other types of data that have been incorporated into the Leapfrog database include static features of the testbed such as natural discontinuities (e.g., fractures, weeps), location of monitoring instruments, and stimulation notches. Baseline geophysical characterization results (e.g., seismic, ERT, temperature, etc.) are also imported into the Leapfrog database. The location and size of packers, various point-source signals detected during stimulation and flow tests (e.g., temperature anomalies, micro-earthquake events, etc.) are also compiled in the database. All feature locations are reported using the local Homestake Mine coordinate system. In this paper, we present some of the geostructural characteristics as well as the status of the testbed as represented by Leapfrog/FracMan database/visualizations.

15 GEOTHERMAL ENERGY↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Virtual finger boosts three-dimensional imaging and microsurgery as well as terabyte volume image visualization and analysis

Three-dimensional (3D) bioimaging, visualization and data analysis are in strong need of powerful 3D exploration techniques. We develop virtual finger (VF) to generate 3D curves, points and regions-of-interest in the 3D space of a volumetric image with a single finger operation, such as a computer mouse stroke, or click or zoom from the 2D-projection plane of an image as visualized with a computer. VF provides efficient methods for acquisition, visualization and analysis of 3D images for roundworm, fruitfly, dragonfly, mouse, rat and human. Specifically, VF enables instant 3D optical zoom-in imaging, 3D free-form optical microsurgery, and 3D visualization and annotation of terabytes of whole-brain image volumes. VF also leads to orders of magnitude better efficiency of automated 3D reconstruction of neurons and similar biostructures over our previous systems. We use VF to generate from images of 1,107 Drosophila GAL4 lines a projectome of a Drosophila brain.

59 BASIC BIOLOGICAL SCIENCES↗

TangibleData: Interactive Data Visualization with Mid-Air Haptics

In this paper, we investigate the effects of mid-air haptics in interactive 3D data visualization. We build an interactive 3D data visualization tool that adapts hand gestures and mid-air haptics to provide tangible interaction in VR using ultrasound haptic feedback on 3D data visualization. We consider two types of 3D visualization datasets and provide different data encoding methods for haptic representations. Two user experiments are conducted to evaluate the effectiveness of our approach. The first experimental results show that adding a mid-air haptic modality can be beneficial regardless of noise conditions and useful for handling occlusion or discerning density and volume information. The second experiment results further show the strengths and weaknesses of direct touch and indirect touch modes. Our findings can shed light on designing and implementing a tangible interaction on 3D data visualization with mid-air haptic feedback.

Bhardwaj, Ayush↗

RCSB Protein Data Bank: Celebrating 50 years of the PDB with new tools for understanding and visualizing biological macromolecules in 3D

We report the Research Collaboratory for Structural Bioinformatics Protein Data Bank (RCSB PDB), funded by the US National Science Foundation, National Institutes of Health, and Department of Energy, has served structural biologists and Protein Data Bank (PDB) data consumers worldwide since 1999. RCSB PDB, a founding member of the Worldwide Protein Data Bank (wwPDB) partnership, is the US data center for the global PDB archive housing biomolecular structure data. RCSB PDB is also responsible for the security of PDB data, as the wwPDB-designated Archive Keeper. Annually, RCSB PDB serves tens of thousands of three-dimensional (3D) macromolecular structure data depositors (using macromolecular crystallography, nuclear magnetic resonance spectroscopy, electron microscopy, and micro-electron diffraction) from all inhabited continents. RCSB PDB makes PDB data available from its research-focused RCSB.org web portal at no charge and without usage restrictions to millions of PDB data consumers working in every nation and territory worldwide. In addition, RCSB PDB operates an outreach and education PDB101.RCSB.org web portal that was used by more than 800,000 educators, students, and members of the public during calendar year 2020. This invited Tools Issue contribution describes (i) how the archive is growing and evolving as new experimental methods generate ever larger and more complex biomolecular structures; (ii) the importance of data standards and data remediation in effective management of the archive and facile integration with more than 50 external data resources; and (iii) new tools and features for 3D structure analysis and visualization made available during the past year via the RCSB.org web portal.

59 BASIC BIOLOGICAL SCIENCES↗

Visualizing Intrinsic 3D-Strain Distribution in Gold Coated ZnO Microstructures by Bragg Coherent X-Ray Diffraction Imaging and Transmission Electron Microscopy with Respect to Piezotronic Applications

Novel devices ranging from bio magnetic field sensors to energy harvesting nano machines utilize the piezotronic effect. For optimal function, understanding the interaction of electrical and strain phenomena within the semiconductor crystal is necessary. Here, studies of a model piezotronic system are presented, consisting of a ZnO microrod coated by a thin layer of gold, which forms a Schottky contact with the piezoelectric ZnO material. Coherent X-ray diffraction imaging (CXDI) and transmission electron microscopy (TEM) are used to visualize the structure and strain distribution, showing that the ZnO microrod exhibits strains of multiple origins in the bulk and at the interface. Strain values of -6 × 10 -4 have been measured by CXDI at the ZnO/Au interface. The origin is shown to be a combination of an interface strain, possibly caused by the Schottky contact formation, and distinct, localized electrical fields inside the crystal which are assigned to electron depletion and screening in a bent ZnO/Au piezotronic rod. These findings will contribute to sensor development and to a better understanding of piezotronic applications.

36 MATERIALS SCIENCE↗

DeepLynx Ecosystem 2025

Poor data integration and governance continue to plague complex engineering projects, resulting in missed cost, schedule, and performance targets. Departments operate in isolated systems with manual data exchange, creating fragmented information that compounds errors and leads to significant delays and cost overruns. The DeepLynx ecosystem addresses these challenges through an open-source, modular data management platform that transforms fragmented project data into an integrated digital thread. Built on a federated microservice architecture, the ecosystem comprises seven specialized tools centered around DeepLynx Nexus, a unified data catalog with hierarchical organization and graph-based navigation capabilities. The ecosystem includes: DeepLynx Stream for real-time timeseries data ingestion from industrial sources; DeepLynx Ingest for governed data uploads with formal review workflows; DeepLynx Lattice for ontology-based entity and relationship extraction; DeepLynx Run for workflow orchestration and secure AI/ML compute; DeepLynx Visualize for 3D digital twin visualization; and DeepLynx Insight for AI-assisted document analysis with traceable, grounded responses. Deployable in cloud, on-premise, or hybrid environments using containerized Docker applications and Helm charts, the DeepLynx ecosystem provides flexible infrastructure that adapts to organizational requirements. By consolidating project data into a unified data lake with role-based access controls and OAuth2 authentication, DeepLynx enables digital thread and digital twin capabilities that improve decision-making, reduce risk, and support complex engineering workflows throughout the project lifecycle.

42 - ENGINEERING↗

A deep learning approach for semantic segmentation of unbalanced data in electron tomography of catalytic materials

In computed TEM tomography, image segmentation represents one of the most basic tasks with implications not only for 3D volume visualization, but more importantly for quantitative 3D analysis. In case of large and complex 3D data sets, segmentation can be an extremely difficult and laborious task, and thus has been one of the biggest hurdles for comprehensive 3D analysis. Heterogeneous catalysts have complex surface and bulk structures, and often sparse distribution of catalytic particles with relatively poor intrinsic contrast, which possess a unique challenge for image segmentation, including the current state-of-the-art deep learning methods. To tackle this problem, we apply a deep learning-based approach for the multi-class semantic segmentation of a γ-Alumina/Pt catalytic material in a class imbalance situation. Specifically, we used the weighted focal loss as a loss function and attached it to the U-Net’s fully convolutional network architecture. We assessed the accuracy of our results using Dice similarity coefficient (DSC), recall, precision, and Hausdorff distance (HD) metrics on the overlap between the ground-truth and predicted segmentations. Our adopted U-Net model with the weighted focal loss function achieved an average DSC score of 0.96 ± 0.003 in the γ-Alumina support material and 0.84 ± 0.03 in the Pt NPs segmentation tasks. We report an average boundary-overlap error of less than 2 nm at the 90th percentile of HD for γ-Alumina and Pt NPs segmentations. The complex surface morphology of γ-Alumina and its relation to the Pt NPs were visualized in 3D by the deep learning-assisted automatic segmentation of a large data set of high-angle annular dark-field (HAADF) scanning transmission electron microscopy (STEM) tomography reconstructions.

36 MATERIALS SCIENCE↗

Automated objective characterization of visual field defects in 3D

A method and apparatus for electronically performing a visual field test for a patient. A visual field test pattern is displayed to the patient on an electronic display device and the patient's responses to the visual field test pattern are recorded. A visual field representation is generated from the patient's responses. The visual field representation is then used as an input into a variety of automated diagnostic processes. In one process, the visual field representation is used to generate a statistical description of the rapidity of change of a patient's visual field at the boundary of a visual field defect. In another process, the area of a visual field defect is calculated using the visual field representation. In another process, the visual field representation is used to generate a statistical description of the volume of a patient's visual field defect.

Fink, Wolfgang↗

Quantitative visualization of synchronized insulin secretion from 3D-cultured cells

Quantitative visualization of synchronized insulin secretion was performed in an isolated rat pancreatic islet and a spheroid of rat pancreatic beta cell line using a method of video-rate bioluminescence imaging. Video-rate images of insulin secretion from 3D-cultured cells were obtained by expressing the fusion protein of insulin and Gaussia luciferase (Insulin-GLase). A subclonal rat INS-1E cell line stably expressing Insulin-GLase, named iGL, was established and a cluster of iGL cells showed oscillatory insulin secretion that was completely synchronized in response to high glucose. Furthermore, we demonstrated the effect of an antidiabetic drug, glibenclamide, on synchronized insulin secretion from 2D- and 3D-cultured iGL cells. The amount of secreted Insulin-GLase from iGL cells was also determined by a luminometer. Thus, our bioluminescence imaging method could generally be used for investigating protein secretion from living 3D-cultured cells. In addition, iGL cell line would be valuable for evaluating antidiabetic drugs. - Highlights: • An imaging method for protein secretion from 3D-cultured cells was established. • The fused protein of insulin to GLase, Insulin-GLase, was used as a reporter. • Synchronous insulin secretion was visualized in rat islets and spheroidal beta cells. • A rat beta cell line stably expressing Insulin-GLase, named iGL, was established. • Effect of an antidiabetic drug on insulin secretion was visualized in iGL cells.

60 APPLIED LIFE SCIENCES↗