Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3-He detector electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Validation of the NOνA experiment 2023-tuning on simulated neutrino-matter interactions

NOνA is a long-baseline neutrino oscillation experiment that utilizes a two-detector design to study the oscillations of muon neutrinos into electron neutrinos over a baseline of 810 km. The Near Detector (ND) measures the neutrino beam spectrum and composition before oscillation, which is then compared to the oscillated neutrino energy spectrum observed in the Far Detector (FD). In the ND, the neutrinos are detected through their interactions with the heavy target nuclei within the detector. NOνA employs the GENIE neutrino event generator for simulating these neutrino-nucleus interactions. However, the default GENIE prediction does not adequately reproduce the ND data. To address this, NOνA developed a tune of the neutrino interaction models within GENIE version 3:0:6 to minimize discrepancies between the simulated predictions and the observed data in the ND. This dissertation tests the NOνA’s 2023 tune of the GENIE neutrino cross-section simulations by performing a data/simulations comparison for the ND. The analysis employed datasets comprising $2.55\times10^{21}$ protons-on-target (POT) in neutrino beam mode and $1.14\times10^{21}$ POT in antineutrino beam mode. The NOνA tuning of neutrino-matter interaction simulations matches with ND data within the $1\sigma$ error band, overestimating muon neutrino and antineutrino charged current interactions by approximately 6 % and 9 %, respectively. Discrepancies were observed in the energy region dominated by Quasi-Elastic-like interactions. Systematic uncertainties associated with the modeling of the neutrino cross-section, particularly those pertaining Quasi-Elastic like interactions, contributed considerably to the overall error in the simulations. Furthermore, the reconstruction algorithm used in NOνA for particle classification demonstrated significant misidentifications between charged pions and protons, as well as a tendency to overlook additional pions or protons in multi-particle simulated events.

Cortés Parra, Camilo Andrés↗

Measuring the impact ionization and charge trapping probabilities in SuperCDMS HVeV phonon sensing detectors

A 0.93 g 1×1×0.4 cm 3 SuperCDMS silicon HVeV detector operated at 30 mK was illuminated by 1.91 eV photons using a room temperature pulsed laser coupled to the cryostat via fiber optic. In this work, the detector’s response under a variety of specific operating conditions was used to study the detector leakage current, charge trapping, and impact ionization in the high-purity Si substrate. The measured probabilities for a charge carrier in the detector to undergo charge trapping (0.713±0.093%) or cause impact ionization (1.576±0.110%) were found to be nearly independent of bias polarity and charge-carrier type (electron or hole) for substrate biases of ±140 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-response of the $N=Z$ nucleus $^{24}$Mg

The electric E1 and magnetic M1 dipole responses of the N = Z nucleus 24 Mg were investigated in an inelastic photon scattering experiment. The 13.0 MeV electrons, which were used to produce the unpolarised bremsstrahlung in the entrance channel of the 24 Mg(γ,γ') reaction, were delivered by the ELBE accelerator of the Helmholtz-Zentrum Dresden-Rossendorf. The collimated bremsstrahlung photons excited one J π = 1 – , four J π = 1 + , and six J π = 2 + states in 24 Mg. De-excitation γ rays were detected using the four high-purity germanium detectors of the γELBE setup, which is dedicated to nuclear resonance fluorescence experiments. In the energy region up to 13.0 MeV a total B(M1)↑ = 2.7(3) $μ$$^{2}_{N}$ is observed, but this N = Z nucleus exhibits only marginal E1 strength of less than ΣB(E1)↑≤ 0.61 × 10 –3 e 2 fm 2 . The B(Π1, $1$$^{π}_{i}$ → $2$$^{+}_{1}$)/B(Π1,$1$$^{π}_{i}$ → $0$$^{+}_{gs}$) branching ratios in combination with the expected results from the Alaga rules demonstrate that K is a good approximative quantum number for 24 Mg. The use of the known ρ 2 (E0, $0$$^{+}_{2}$ → $0$$^{+}_{gs}$) strength and the measured B(M1,1 + → $0$$^{+}_{2}$)/B(M1,1 + → $0$$^{+}_{gs}$) branching ratio of the 10.712 MeV 1 + level allows, in a two-state mixing model, an extraction of the difference Δ$β$$^{2}_{2}$ between the prolate ground-state structure and shape-coexisting superdeformed structure built upon the 6432-keV $0$$^{+}_{2}$ level.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging and structure analysis of ferroelectric domains, domain walls, and vortices by scanning electron diffraction

Direct electron detectors in scanning transmission electron microscopy give unprecedented possibilities for structure analysis at the nanoscale. In electronic and quantum materials, this new capability gives access to, for example, emergent chiral structures and symmetry-breaking distortions that underpin functional properties. Quantifying nanoscale structural features with statistical significance, however, is complicated by the subtleties of dynamic diffraction and coexisting contrast mechanisms, which often results in a low signal-to-noise ratio and the superposition of multiple signals that are challenging to deconvolute. Here we apply scanning electron diffraction to explore local polar distortions in the uniaxial ferroelectric Er(Mn,Ti)O 3 . Using a custom-designed convolutional autoencoder with bespoke regularization, we demonstrate that subtle variations in the scattering signatures of ferroelectric domains, domain walls, and vortex textures can readily be disentangled with statistical significance and separated from extrinsic contributions due to, e.g., variations in specimen thickness or bending. The work demonstrates a pathway to quantitatively measure symmetry-breaking distortions across large areas, mapping structural changes at interfaces and topological structures with nanoscale spatial resolution.

36 MATERIALS SCIENCE↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the Solution Chemistry of Hybrid Organic–Inorganic Indium Halides for New Material Discovery

Recently, metal halide perovskites (MHPs) have emerged as a new class of materials for optical and electronic applications such as solar cells and ionizing radiation detectors. Although the solution-processability of MHPs is among their greatest advantages, the solution chemistries of most metal halide systems and their relationship with the observed structural and chemical diversity are poorly understood. In this work, we study the solution chemistry of a model indium halide system, methylammonium (MA)–In–Br, using a combination of the UV–vis spectroscopy, electrospray ionization mass spectrometry (ESI-MS) measurements, small-angle X-ray scattering (SAXS), and density functional theory (DFT) calculations. Our results show that indium could form either octahedral [InBr 6 3– ] or tetrahedral [InBr 4 – ] anions in solution or a combination of both, depending on the loading ratios of MABr and InBr 3 reactants. Understanding the solution chemistry of this system and recognizing the optical fingerprints of these polyanions allow for targeted crystallization of two novel compounds: MAInBr 4 featuring tetrahedral [InBr 4 – ] anions and MA 2 InBr 5 containing both octahedral [InBr 6 3– ] and tetrahedral [InBr 4 – ] anions. Further increase of the MABr content leads to the formation of previously reported MA 4 InBr 7 , containing only octahedral [InBr 6 3– ] anions separated by Br – anions. Furthermore, our results suggest that understanding the solution chemistry of multinary metal halide systems could be a valuable tool for discovering functional materials for practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-slice electron ptychographic tomography for three-dimensional phase-contrast microscopy beyond the depth of focus limits

Electron ptychography is a powerful computational method for atomic-resolution imaging with high contrast for weakly and strongly scattering elements. Modern algorithms coupled with fast and efficient detectors allow imaging specimens with tens of nanometers thicknesses with sub-0.5 Ångstrom lateral resolution. However, the axial resolution in these approaches is currently limited to a few nanometers, limiting their ability to solve novel atomic structures ab initio. Here, we experimentally demonstrate multi-slice ptychographic electron tomography, which allows atomic resolution three-dimensional phase-contrast imaging in a volume surpassing the depth of field limits. We reconstruct tilt-series 4D-STEM measurements of a $\mathrm{Co_3O_4}$ nanocube, yielding 2 Å axial and 0.7 Å transverse resolution in a reconstructed volume of $\mathrm{(18.2\,nm)^3}$. Our results demonstrate a 13.5-fold improvement in axial resolution compared to multi-slice ptychography while retaining the atomic lateral resolution and the capability to image volumes beyond the depth of field limit. Multi-slice ptychographic electron tomography significantly expands the volume of materials accessible using high-resolution electron microscopy. We discuss further experimental and algorithmic improvements necessary to also resolve single weakly scattering atoms in 3D.

36 MATERIALS SCIENCE↗

Search for signatures of sterile neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e. comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range ${5 \times 10^{-3}}\,\mathrm{eV}^2 \lesssim \varDelta m^2_{41} \lesssim {3 \times 10^{-1}}\,\mathrm{eV}^2$ for mixing angles down to $\sin ^2 2\theta _{14} \gtrsim {0.02}$. No significant disappearance additionally to the conventional disappearance related to $\theta _{13}$ is observed and correspondingly exclusion bounds on the sterile mixing parameter $\theta _{14}$ as a function of $\varDelta m^2_{41}$ are obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for New Physics with the Compact Muon Solenoid Experiment and QIS-enabled Technology

Understanding the fundamental nature of dark matter (DM)---its cosmological origin, constituents, and interactions---is one of the most important questions in fundamental science today. In this thesis, I present two novel and highly complementary approaches to cover the gaps in sensitivity of current DM searches. The searches are enabled by a first-of-its-kind reconstruction technique to search for hidden-sector particles using the Compact Muon Solenoid (CMS) and by new advances in quantum sensing technology to search for axions and hidden-sector DM. In the first part of this thesis, I present a search for long-lived hidden sector particles, predicted by many extensions of the SM, using a novel technique to reconstruct decays of long-lived particles (LLPs) in the CMS muon detector. The innovative LLP reconstruction technique is sensitive to a broad range of LLP decays and to LLP masses below GeV. The search yields competitive sensitivity for proper lifetime 0.1--1000 m with the full Run 2 dataset recorded at the LHC between 2016--2018 at $\sqrt{s} = 13~$TeV. To extend the physics reach of this novel muon detector shower (MDS) signature, I present the model-independence of MDS and the reinterpretation of the search to a large number of LLP models, demonstrating its complementarity with proposed and existing dedicated LLP experiments. Finally, I present a new dedicated MDS trigger that improves the trigger efficiency by at least an order of magnitude and was deployed in 2022, at the start of Run 3 of the LHC operations. In the second part of the thesis, I present for the first time, the use of a novel quantum sensor, the low-noise and single-photon sensitive superconducting nanowire single photon detectors (SNSPDs), to directly detect dark matter. The low detection threshold and ultra-low dark count rate of SNSPDs can close the gap in DM discovery reach due to the current limitations in detector sensitivity. I will present my work on the development and characterization of SNSPDs for two entirely new experiments to directly detect axions via absorption and hidden-sector DM via electron scattering. The search for axions employs a novel broadband reflector technique with the Broadband Reflector Experiment for Axion Detection (BREAD). A unique parabolic mirror is then used to focus axion-converted photons to the SNSPDs, extending the reach to axion masses of 0.04--1 eV. On the other hand, by coupling the SNSPDs with gallium arsenide, a bright cryogenic scintillator well matched to SNSPD detection, a prototype sensing system can be built as a basis of new direct DM detection experiments capable of extending the discovery to DM masses as low as 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000↗

Large magnetoresistance and quantum oscillations observed in superconducting β -IrSn 4

Diverse quantum phenomena have been observed in TSn 4 transition metal (T) stannides, including superconductivity, nontrivial topology, and large magnetoresistance (MR) at low temperatures. Here, we report the experimental and theoretical investigation of tetragonal β-IrSn 4 (space group I 4 1 /acd) with the lattice parameters a = 6.362(3) Å and c = 22.723(0) Å. The temperature dependence of the electrical resistivity indicates that β-IrSn 4 is a good metal with Fermi-liquid behavior above the superconducting transition at T c ∼ 0.7 K. Magnetic susceptibility measurements indicate it is non-magnetic. However, positive transverse MR with linear field dependence is observed. At T= 2 K and Μ 0 H = 14 T, the MR reaches 700% without sign of saturation. Shubnikov–de Haas oscillations are observed from proximity detector oscillator measurements up to 60 T. We experimentally extract several frequencies, and through comparison to first-principles calculations, identify corresponding electronic bands. For H // c, two strong oscillations, F 1 ≈ 109 and F 2 ≈ 302 T, allow us to determine effective masses 0.266m 0 and 0.300m 0 (m 0 is the free-electron mass), respectively. The topology of these bands is discussed.

36 MATERIALS SCIENCE↗

Physics Opportunities in the Far-forward Region at the Future Electron–Ion Collider

The Electron–Ion Collider provides the opportunity to drastically advance our understanding of QCD and the multidimensional structure of both protons and nuclei. An essential component of the EIC physics program is the identification and characterization of exclusive, diffractive, and tagged events using detectors integrated with the outgoing hadron beamline, the so-called “far-forward” detectors. The ePIC experiment includes a suite of far-forward detectors designed to deliver the necessary geometric coverage and resolution required to achieve the exclusive physics program envisioned at the EIC. Additionally, to the multidimensional imaging program at the EIC, topics such as spectator tagging in e + d and e + 3 He reactions to access structure functions and searches for gluon saturation in e + A collisions are also enabled by this experimental apparatus. In these proceedings, the ePIC far-forward detectors will be briefly introduced, and a few selected physics topics focused on tagged deep-inelastic scattering will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for e → τ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D diffractive imaging of nanoparticle ensembles using an x-ray laser

Single particle imaging at x-ray free electron lasers (XFELs) has the potential to determine the structure and dynamics of single biomolecules at room temperature. Two major hurdles have prevented this potential from being reached, namely, the collection of sufficient high-quality diffraction patterns and robust computational purification to overcome structural heterogeneity. We report the breaking of both of these barriers using gold nanoparticle test samples, recording around 10 million diffraction patterns at the European XFEL and structurally and orientationally sorting the patterns to obtain better than 3-nm-resolution 3D reconstructions for each of four samples. With these new developments, integrating advancements in x-ray sources, fast-framing detectors, efficient sample delivery, and data analysis algorithms, we illuminate the path towards sub-nanometer biomolecular imaging. The methods developed here can also be extended to characterize ensembles that are inherently diverse to obtain their full structural landscape.

47 OTHER INSTRUMENTATION↗

Models to Incorporate Reaction Mechanisms into DG-OSPREY: Fixed-Bed Simulations for Organic Iodides Capture Using Ag 0 Z

As one of the most potent radioisotopes released during spent nuclear fuel reprocessing, 129 I is strictly regulated and must be removed before discharge. Organic iodides (primarily alkyl iodides with different chain lengths, i.e., CH 3 I, C 4 H 9 I, and C 12 H 25 I) comprise ~2% of the total iodine in the reprocessing off-gases and are primarily present in vessel off-gas (VOG). Reduced silver mordenite (Ag 0 Z) is predominantly considered for the removal of radioiodine; however, its capture performance and underlying interaction processes with long-chain organic iodides are not fully understood. Two major tasks were accomplished in this study. First, to improve upon the previous experimental studies where Ag 0 Z was used to capture CH 3 I, C 4 H 9 I, and C 12 H 25 I at different concentrations, we comprehensively investigated the corresponding capture mechanisms by characterizing fully loaded Ag 0 Z samples. Second, computational codes were implemented to perform fixed-bed simulations that account for transport and reaction mechanisms. Scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX), powder X-ray diffraction (PXRD), UV-visible diffuse reflectance spectroscopy (UV-vis DRS), and thermogravimetric analysis (TGA) were conducted on Ag 0 Z samples that are saturated with I 2 , CH 3 I, C 4 H 9 I, and C 12 H 25 I), respectively. Results indicate that AgI is the predominant adsorption product regardless of the adsorbed iodine species, yet alkyl iodides with different carbon chain lengths may have different compositions of α- and γ-AgI. Synchrotron pair distribution function (PDF) measurements and TGA coupled with a Fourier transformed infrared detector (TGA FTIR) have been performed, and experimental data are currently analyzed. Results are expected to provide further insights into the adsorption mechanisms. The fixed-bed capture performance for CH 3 I was successfully simulated by solving mathematical equations that describe the underlying transport processes and adsorption reactions. The computational framework, Catalytic After Treatment System (CATS), that was originated in our research group, was used to solve the governing equations. Kinetic parameters, including the pore diffusivity and reaction rate constant were obtained by optimization techniques using data from thin-bed experiments performed at Oak Ridge National Laboratory. The performance of a deep bed predicted using the optimized parameters showed promising agreement with the experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗