The High-Luminosity Large Hadron Collider (HL-LHC) will operate at unprecedented luminosities, resulting in up to 200 simultaneous interactions per bunch crossing. To mitigate the resulting pileup challenges, the CMS experiment is implementing the MIP Timing Detector (MTD), designed to provide precise timing information with a resolution of 30 – 40 picoseconds per track. The MTD consists of the Barrel Timing Layer (BTL) and the Endcap Timing Layer (ETL), each optimized for different regions of the detector. The ETL, comprising two double-sided disks, utilizes Low-Gain Avalanche Diode (LGAD) sensors coupled with the Endcap Timing Readout Chip (ETROC) to achieve high-precision timing measurements in the forward region. Significant progress has been made toward the realization of the ETL through extensive system-level validation of the ETROC readout chain and the development of scalable module assembly procedures. This presentation will provide a comprehensive overview of the ETL and highlight recent advances in system validation and module assembly, emphasizing their roles in ensuring the detector readiness for HL-LHC operation.