Engineering PapersSearch

DOE OSTI · 2496637

High pressure Raman spectroscopy of boron-rich boron carbides up to 50 GPa

Abstract

We investigated the effects of increased boron content on the resistance to non-hydrostatic stress-induced (NHSI) local amorphous zones in boron-rich boron carbide (BxC) compounds. Using high-pressure Raman spectroscopy, we subjected B 4.3 C, B 6.4 C, and B 10.4 C to pressures up to 50 GPa and monitored their responses. Our results show that higher boron content delays the onset of NHSI local amorphous zone formation, shifting it from 35 GPa in B 4.3 C to approximately 50 GPa in B 10.4 C. This enhanced resistance is attributed to a reduction in the formation of the B 12 (CCC) polytype, which is susceptible to amorphization, and the greater flexibility of B–B–B chains. Furthermore, alternative mechanisms, such as boron vacancy-driven C–C bond formation, provide additional insights into defect-mediated structural changes that may influence the amorphization process. In conclusion, these findings highlight the dual role of boron content and defect mechanisms in improving the structural stability of B x C materials under extreme environments.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sereika, Raimundas [University of Alabama at Birmingham, AL (United States); University of Alabama at Birmingham], Iwan, Seth [University of Alabama at Birmingham, AL (United States)], Baker, Paul A. [University of Alabama at Birmingham, AL (United States)], Vohra, Yogesh K. [University of Alabama at Birmingham, AL (United States)]. 2025-01-06. High pressure Raman spectroscopy of boron-rich boron carbides up to 50 GPa. https://doi.org/10.1080/08957959.2024.2449365

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE