Engineering Papers⌕ Search

DOE OSTI · 2341467

System Study: High-Pressure Coolant Injection 1998-2022

Abstract

This report presents an unreliability evaluation of the high-pressure coolant injection (HPCI) system at 22 U.S. commercial operating boiling water reactors. New Standardized Plant Analysis Risk (SPAR) models with the most recent SPAR parameter update results were used in this report. Demand, run hour, and failure data from 1998–2022 for selected components were obtained from the Institute of Nuclear Power Operations Industry Reporting and Information System. The unreliability results are trended for the most recent 10 year period while yearly estimates for system unreliability are provided for the entire active period. No statistically significant increasing or decreasing trends were identified in the HPCI results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ma, Zhegang, Kvarfordt, Kellie J., Wierman, Thomas. 2023-12-01. System Study: High-Pressure Coolant Injection 1998-2022. https://doi.org/10.2172/2341467

Cite the original work for its findings. Save a collection to share your selection of sources.