On-the-fly response function generation method for composite coarse mesh

Abstract

The hybrid stochastic deterministic transport code COMET, based on the incident response expansion theory, is used to model reactor cores with high fidelity and formidable computational speed. COMET models a reactor core using a library of incident flux response expansion coefficients that are pre computed for all the unique lattice cells (e.g., fuel assemblies, reflector blocks, etc.) in the core. In order to further improve its computational efficiency in pre-calculating the response library a new response function generation method is developed to compute the response functions for the composite coarse meshes made of a smaller set of unique lattices on the fly within the COMET's deterministic transport core sweep. The efficiency is achieved by eliminating a number of unique lattices that can be made up from the reduced set of unique meshes on the fly. The numerical process consists of the following steps. First, the boundary condition on composite coarse mesh boundaries is projected onto the expansion basis to compute the incident flux moments on external surfaces of all the basic (reduced set of unique) coarse meshes. Secondly, the deterministic sweeping solver in COMET is used to converge on the outgoing/incoming flux expansion moments crossing interfaces between the basic coarse meshes. Thirdly, the response functions for the composite coarse meshes are constructed as a superposition on the fly. The new response function generation method was tested on 88 composite coarse meshes consisting of CANDU fuel bundles and moderator blocks. It was found that response functions generated by the new method agree very well with those generated by direct Monte Carlo calculations. The average and maximum relative differences in the surface-to-surface response coefficients computed by the two methods are 0.10% and 0.20%, respectively. Similarly, the average and maximum relative differences in the response fission densities are 0.13% and 0.43%, respectively. These discrepancies are within one standard deviation of the stochastic uncertainties. The new method is five times faster than the original direct Monte Carlo method. The size of the response function library for the new method is five times smaller than that for the original method, leading to significantly less requirement for the computer hard drive space and memory. (authors)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhang, D., Rahnema, F.. 2022-07-01. On-the-fly response function generation method for composite coarse mesh. https://doi.org/10.13182/physor22-37775

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Machine Learning–Based Condition Monitoring of a Circulating Water System of a Canadian Nuclear Plant

With the need to maintain long-term reliable energy using nuclear power plants, there is an underlying demand to ensure that the maintenance of plant components and systems is also done in an efficient and cost-effective manner. One way to achieve this is by moving from time-based maintenance to condition-based maintenance. The research presented in this paper focuses on applying statistical and machine-learning-based methods to capture anomalies within data for fault detection to further develop into condition monitoring. This paper focuses on system data for a circulating water system (CWS) of a pressurized heavy-water reactor for detecting anomalies. The different methodologies used for detecting and capturing anomalies in the CWS data are matrix profile, density-based spatial clustering of applications with noise (DBSCAN), and support vector machines (SVMs). Matrix profile and DBSCAN are used to distinguish between normal data and anomalous data. This paper presents a hybrid method using DBSCAN and SVM when a portion of the data is used for DBSCAN to generate clusters. This portion of data is then used to train the SVM along with the clusters generated by DBSCAN as output. SVM is then tested on unseen data as a predictive tool, which can work in real time to categorize data points as either normal or anomalous. This paper presents results that show the high accuracies of DBSCAN and SVM in capturing anomalies within the data for a CWS for fault detection. Thus, the maintenance plan would be focused on component condition rather than a time-based schedule by switching to an automated system to identify and predict faults within a CWS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SCALE HTR-PROTEUS Benchmark Model

This dataset contains input and result files of computational simulations of HTR-PROTEUS benchmark with the latest version of SCALE code system. The simulations cover criticality control rod worth calculations as well as sensitivity analysis and uncertainty quantification. Users wanting to reproduce results from this dataset are required to obtain a license to the SCALE code system for which details on the distribution can be found here: https://www.ornl.gov/scale/releases

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗