On January 8, 2007 a hydrogen explosion at the Msukingum River Power plant's 585-MW coal-fired supercritical unit 5 caused one fatality, injuries to 10 other people and significant damage to several buildings. The explosion occurred during a routine delivery of hydrogen, used to cool generating units, when a hydrogen relief device failed, which allowed the contents of the hydrogen tank to escape and be ignited by an unknown source. This article covers the findings of the incident investigation and the actions the plant has taken to prevent a reoccurrence. 4 photos.