Engineering Papers⌕ Search

DOE OSTI · 21045976

Correlation Between Detector Array Measurements and a Computer Algorithm for Enhanced Dynamic Wedge Profiles

Abstract

Verification of dosimetric data computed by a treatment planning system is necessary in the commissioning process for any clinical software, just as it is necessary for any annual quality assurance testing. Direct verification of the dosimetric data is achievable when calculating the enhanced dynamic wedge (EDW) off-axis ratio at each point of interest. As mathematical models for hand-calculating such factors are still evolving, measurement of these external beam arrangements has proven significantly more accurate. This research presents a correlation for measured and planned data, specific for 6- and 18-MV photon beams on a Varian 21EX linear accelerator, using the EDW mode. Field generation was created using the Varian Eclipse treatment planning system. On treatment field delivery, the Sun Nuclear MapCHECK diode array was used to plot each beam profile in 2 dimensions. Wedge angles of 10 deg., 15 deg., 20 deg., 25 deg., 30 deg., 45 deg. and 60 deg. were studied here, under isocentric geometry, at a fixed water equivalent depth of 15 cm. Field size dependence was considered with each wedge and energy combination, where symmetric apertures of 5 x 5 cm{sup 2}, 10 x 10 cm{sup 2}, 15 x 15 cm{sup 2} and 20 x 20 cm{sup 2} were used. Accurate dosimetric results were found to be achievable when using this treatment planning system to within 2.8% maximum deviation, and to within 1% deviation averaged over all. The diode array also proved to be simple and ideally suited for EDW measurements.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robertson, Mary A, Lawson, Raymond C. 2007-10-01. Correlation Between Detector Array Measurements and a Computer Algorithm for Enhanced Dynamic Wedge Profiles. https://doi.org/10.1016/j.meddos.2007.02.001. https://engineeringpapers.com/record/osti%3A21045976/correlation-between-detector-array-measurements-and-a-computer-algorithm-for-enhanced-dynamic-wedge

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Engineering Papers by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related reports

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

ACRRF High-Bay Dose Calculations using MCNP (Part B)

ACRR radiation outputs through vertical cavities have been documented in two reports. In Part B, the maximum dose from the unshielded central cavity, FREC-II, and NRS is calculated to inform the safety basis. The maximum dose is ≈1430 mrem per 300 MJ, or ≈40,930 rem/hr for full-power operation. A verification study completes the V&V of the modeling. Supplementary studies of variance-reduction techniques, model sensitivities, and aircraft dose above the ACRRF are included.

61 RADIATION PROTECTION AND DOSIMETRY↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗