Abstract
On October 15, 2021, the Radioactive and Hazardous Waste Management Facility Manager declared a Potential Inadequacy in the Safety Analysis (PISA) due to a new information relating to an error discovered in calculation AB-WSF-20-002. Calculation AB-WSF-20-002 is used to determine source terms and heat release rates for vehicle and aircraft impacts with fuel fires involving TRU waste containers. The source term for an aircraft’s impact has different source terms factors (i.e., DR, ARF, RF, LPF) that are applied to multiple categories of drums impacted in the accident scenario based on the physical stresses of the aircraft impact and involvement in the subsequent fuel pool fire. The source terms of the multiple categories of affected drums are summed to determine the final source term for the accident scenario. Certain categories of affected drums are modeled to lose their lid, causing material to eject and burn unconfined on the ground. For these specific categories, a lower ARF value was incorrectly applied in AB-WSF-20-002 (i.e., an ARF value of 1E-3 was used instead of the DOE-STD-5506-2007 directed ARF value of 1E-2). For these categories, the ARF is applied to a relatively small number of low-activity drums (i.e., 17 drums at 2.9 PE-Ci each) compared to the total number of drums affected (i.e., 166 drums totaling 621.8 PE-Ci). Therefore, this error is not expected to significantly increase final dose for the accident scenario. No immediate actions or compensatory measures are required to maintain the facility in a safe condition.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Laycak, D.. 2021-11-08. WSF PISA example for SAFER pilot. https://doi.org/10.2172/1829599
Cite the original work for its findings. Save a collection to share your selection of sources.