Engineering Papers⌕ Search

DOE OSTI · 1683898

Materials Data on Sr4CaYGa2(Cu2O7)2 by Materials Project

Abstract

Sr4CaYGa2(Cu2O7)2 crystallizes in the monoclinic C2 space group. The structure is three-dimensional. there are two inequivalent Sr2+ sites. In the first Sr2+ site, Sr2+ is bonded in a 9-coordinate geometry to nine O2- atoms. There are a spread of Sr–O bond distances ranging from 2.48–3.13 Å. In the second Sr2+ site, Sr2+ is bonded in a 9-coordinate geometry to nine O2- atoms. There are a spread of Sr–O bond distances ranging from 2.48–3.12 Å. Ca2+ is bonded in a body-centered cubic geometry to eight O2- atoms. There are a spread of Ca–O bond distances ranging from 2.44–2.51 Å. Y3+ is bonded in a body-centered cubic geometry to eight O2- atoms. There are four shorter (2.39 Å) and four longer (2.44 Å) Y–O bond lengths. There are two inequivalent Cu+2.25+ sites. In the first Cu+2.25+ site, Cu+2.25+ is bonded to five O2- atoms to form CuO5 square pyramids that share corners with four equivalent CuO5 square pyramids and a cornercorner with one GaO4 tetrahedra. There are a spread of Cu–O bond distances ranging from 1.93–2.41 Å. In the second Cu+2.25+ site, Cu+2.25+ is bonded to five O2- atoms to form CuO5 square pyramids that share corners with four equivalent CuO5 square pyramids and a cornercorner with one GaO4 tetrahedra. There are a spread of Cu–O bond distances ranging from 1.93–2.40 Å. Ga3+ is bonded to four O2- atoms to form GaO4 tetrahedra that share corners with two CuO5 square pyramids and corners with two equivalent GaO4 tetrahedra. There are a spread of Ga–O bond distances ranging from 1.85–1.92 Å. There are seven inequivalent O2- sites. In the first O2- site, O2- is bonded in a 1-coordinate geometry to four Sr2+, one Cu+2.25+, and one Ga3+ atom. In the second O2- site, O2- is bonded to two Sr2+, one Ca2+, one Y3+, and two Cu+2.25+ atoms to form distorted OSr2CaYCu2 octahedra that share corners with two equivalent OSr2CaYCu2 octahedra and corners with two equivalent OSr2Ga2 tetrahedra. The corner-sharing octahedra tilt angles range from 65–67°. In the third O2- site, O2- is bonded in a 6-coordinate geometry to two Sr2+, one Ca2+, one Y3+, and two Cu+2.25+ atoms. In the fourth O2- site, O2- is bonded to two Sr2+ and two equivalent Ga3+ atoms to form distorted OSr2Ga2 tetrahedra that share corners with two equivalent OSr2CaYCu2 octahedra and corners with two equivalent OSr2Ga2 tetrahedra. The corner-sharing octahedra tilt angles range from 53–66°. In the fifth O2- site, O2- is bonded in a 6-coordinate geometry to two Sr2+, one Ca2+, one Y3+, and two Cu+2.25+ atoms. In the sixth O2- site, O2- is bonded in a 6-coordinate geometry to two Sr2+, one Ca2+, one Y3+, and two Cu+2.25+ atoms. In the seventh O2- site, O2- is bonded in a 1-coordinate geometry to four Sr2+, one Cu+2.25+, and one Ga3+ atom.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

2020-05-03. Materials Data on Sr4CaYGa2(Cu2O7)2 by Materials Project. https://doi.org/10.17188/1683898

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Cyclic moisture reactivation of calcium sorbents for long duration thermochemical energy storage

The transition to a flexible and reliable energy infrastructure, using electro-thermal energy generation technologies such as geothermal, concentrated solar power, and nuclear, usually demands simultaneous advancement of thermal energy storage (TES) to support on-demand electricity generation and industrial applications while mitigating the inherent intermittency of renewable energy sources and power outages from direct energy generation. Among TES technologies, thermochemical energy storage (TCES) based on calcium looping emerges as a compelling high-power energy storage candidate due to its high reaction enthalpy, compatibility with elevated operating temperatures, and abundance of low-cost materials. However, the long-term durability of calcium-based sorbents for TCES is hindered by surface sintering and particle aggregation, leading to performance degradation over repeated thermal cycles. This study explores a moisture hydration-based strategy to regenerate a degraded calcium sorbent and mitigate performance degradation for long duration TCES. The addition of moisture transforms calcium oxide into calcium hydroxide and produces intercalation water layers, associated with a regenerated surface area and reduced calcium oxide crystallite size. Both these effects are beneficial in restoring the sorbents' reactivity for carbonization. Additionally, an optimized hydration-assisted reactivation protocol balances the recovered energy storage capacity with heating penalty required for moisture removal from hydrated samples, resulting in an enhanced energy storage capacity up to 176% compared to benchmark sorbents that undergo cycling without reactivation after 60 cycles. In conclusion, these results highlight the potential of hydration-assisted reactivation to enhance the long-term performance of TCES, providing an effective pathway to advancing electro-thermal storage technologies.

36 MATERIALS SCIENCE↗