The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the results for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis of the RDX Type II Class 5 standard, from testing the second time in the Proficiency Test. This RDX testing (Set 2) compared to the first (Set 1) was found to have about the same impact sensitivity, have more BAM friction sensitivity, less ABL friction sensitivity, similar ESD sensitivity, and same DSC sensitivity.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Sandstrom, Mary M., Brown, Geoffrey W., Preston, Daniel N., Pollard, Colin J., Warner, Kirstin F., Sorensen, Daniel N., Remmers, Daniel L., Phillips, Jason J., Shelley, Timothy J., Reyes, Jose A., Hsu, Peter C., Reynolds, John G.. 2013-02-20. Integrated Data Collection Analysis (IDCA) Program - RDX Standard Data Set 2. https://doi.org/10.2172/1305884