Lessons Learned in Hydrogen System Operation

Abstract

NASA has learned extensive lessons on the operations of hydrogen systems during the developments and operations of space hardware. A subset of these lessons that are useful for aircraft and terrestrial applications using liquid hydrogen are presented to help disseminate the information learned. Discussion includes test data, analysis, and observations on cryogenic insulation systems, stratification and temperature gradients within tank systems, fittings to reduce leakage, and integration of refrigeration systems within a cryogenic fluids system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wesley Johnson. Lessons Learned in Hydrogen System Operation. https://ntrs.nasa.gov/citations/20230012474

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Performance Testing of Liquid Hydrogen Tanks

Testing the performance of liquid hydrogen in tanks brings many unique challenges. Often methods used even for liquid nitrogen need to be modified to be able to address the details required to fully understand the performance of the tank. During the development and characterization of many novel insulation systems both for in-space and ground applications, NASA has tested many liquid hydrogen tanks where performance was a key outcome. Over the course of analyzing the performance of multiple different hydrogen tests, including several with both hydrogen and nitrogen, differences in the details of test data interpretation become clear. One of these key details is the thermal stratification of the tank and what it can tell you about the heat load dispersion.

Liquid Hydrogen

Warm Pressurant Gas Effects on the Liquid Hydrogen Bubble Point

This paper presents experimental results for the liquid hydrogen bubble point tests using warm pressurant gases conducted at the Cryogenic Components Cell 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. The purpose of the test series was to determine the effect of elevating the temperature of the pressurant gas on the performance of a liquid acquisition device. Three fine mesh screen samples (325 x 2300, 450 x 2750, 510 x 3600) were tested in liquid hydrogen using cold and warm noncondensible (gaseous helium) and condensable (gaseous hydrogen) pressurization schemes. Gases were conditioned from 0 to 90 K above the liquid temperature. Results clearly indicate a degradation in bubble point pressure using warm gas, with a greater reduction in performance using condensable over noncondensible pressurization. Degradation in the bubble point pressure is inversely proportional to screen porosity, as the coarsest mesh demonstrated the highest degradation. Results here have implication on both pressurization and LAD system design for all future cryogenic propulsion systems. A detailed review of historical heated gas tests is also presented for comparison to current results.

Liquid Hydrogen

Liquid Hydrogen and other Cryogenic Instrumentation Experience at NASA Glenn

NASA has learned extensive lessons on instrumentation of hydrogen systems during technology developments activities focused on the development of in-space cryogenic fluid management technologies. A subset of these lessons that are useful for aircraft and terrestrial applications using liquid hydrogen are presented to help disseminate the information learned. Discussion includes temperature, pressure, flow, and mass gauging options.

Liquid Hydrogen