Engineering PapersSearch

NASA NTRS · 20200003907

Detection of Trace Silicone Contamination on Carbon Fiber Reinforced Composite (CFRP) Surfaces by Picosecond Laser Induced Breakdown Spectroscopy (LIBS)

Abstract

The source did not provide an abstract. Follow the original record for more information.

Keep this discovery

BibTeXRIS

Rodolfo Ledesma, Frank Palmieri, John Connell. Detection of Trace Silicone Contamination on Carbon Fiber Reinforced Composite (CFRP) Surfaces by Picosecond Laser Induced Breakdown Spectroscopy (LIBS). https://ntrs.nasa.gov/citations/20200003907

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related reports

Mechanical Properties of Carbon Fiber Reinforced Composites Exposed to Cryogenic Conditions and Space Radiation via Simulation and Testing

As NASA missions extend beyond low Earth orbit, increasing reliance is placed on carbon fiber reinforced polymer (CFRP) composites for spacecraft structures where mass efficiency, durability, and long-term reliability are critical. In service, these materials are subjected to a combination of ultraviolet radiation, vacuum, ionizing radiation, atomic oxygen, and extreme thermal excursions under sustained mechanical loading. Flight systems such as the Boeing Starliner and SpaceX Dragon employ external composite structures that will experience these environments for extended durations. Although prior spaceflight and ground studies have reported limited changes in bulk mechanical properties, the synergistic effects of these environments on composite microstructure, particularly at the fiber matrix interphase, remain insufficiently characterized and represent a potential qualification and reliability risk. This study investigates the effects of short-term cryogenic exposure on a radiation shielding carbon epoxy composite, SC2020, as a ground-based analog for space relevant thermal extremes. The SC2020 material system has previously flown on the International Space Station under the Materials International Space Station Experiment (MISSE) program. Composite specimens were exposed to liquid nitrogen for 6 and 24 hours and evaluated using a multiscale characterization framework that combined ASTM D3039 tensile testing, Atomic Force Microscopy (AFM) based interphase analysis, and helium gas permeability measurements. Tensile testing showed no statistically significant or permanent degradation in global strength or modulus following cryogenic exposure. In contrast, AFM measurements revealed reductions in interphase modulus, weakened adhesion, and increased nanoscale heterogeneity, indicating localized degradation mechanisms not captured by conventional bulk testing. Gas permeability measurements showed a progressive increase in helium diffusion with exposure duration, consistent with micro-void formation or partial interfacial debonding. The results indicate that cryogenic exposure initiates degradation at the fiber matrix interphase while leaving global mechanical properties largely unchanged over short durations. These findings underscore the importance of multiscale diagnostics for identifying early-stage damage mechanisms that may influence long term performance and qualification margins for spaceflight composite structures. The data presented establish a cryogenic baseline for comparison with forthcoming MISSE flight exposure results and support ongoing NASA Established Program to Stimulate Competitive Research (EPSCoR) efforts aimed at improving composite qualification methodologies, risk assessment, and reliability prediction for space environments.

composite reliability

PET waste- and bio-derived imine vitrimers for shape-memory, intrinsic flame-retardant, and recyclable carbon fiber composites

Developing circular multifunctional vitrimers and carbon fiber–reinforced polymers (CFRPs) that are simultaneously recyclable, mechanically robust, and intrinsically flame retardant remains a major challenge. Here, in this study, we report multifunctional vitrimers and their carbon fiber–reinforced vitrimer (CFRV) composites, where the vitrimer design integrates closed-loop recyclability, enhanced interfacial adhesion, and intrinsic flame retardancy within a single materials platform. The vitrimer matrix is synthesized from post-consumer polyethylene terephthalate (PET) waste and a vanillin-derived phosphorus-containing crosslinker, forming an imine-based network. The resulting vitrimer resin exhibits high tensile strength, thermal healability, repeated reprocessability, programmable shape memory, and rapid chemical depolymerization under mild conditions. Amine-functionalized carbon fibers significantly improve fiber–matrix interfacial bonding, yielding CFRVs with tensile strengths up to 789 MPa and complete recovery of structurally intact fibers after chemical recycling. The phosphorus-rich aromatic network further imparts intrinsic flame retardancy, enabling self-extinguishing behavior without external additives. This work advances a materials design paradigm for next-generation multifunctional, sustainable vitrimers and CFRVs, while simultaneously addressing the recycling challenges associated with both plastic and CFRP waste.

Bio-derived crosslinker

Effects of high-dose neutron irradiation at light-water reactor relevant temperature on the mechanical properties of SiC/SiC composites

For this study, the neutron dose-dependent evolutions and the underlying mechanisms of properties of SiC fiber-reinforced SiC matrix (SiC/SiC) composites at a temperature relevant to light-water reactors (∼600 K) were investigated and analyzed. Chemical vapor infiltrated (CVI) SiC/SiC composites reinforced with Hi-Nicalon Type S or Tyranno SA3 fiber were neutron-irradiated to doses up to 30 dpa. The irradiated composites retained their flexural strengths. The thermal diffusivity and dimensional changes were mostly retained from 2.0 to 30.2 dpa. Discrepancies in irradiation responses among CVI SiC/SiC composites from different sources were found. Additional microstructural analysis using Raman spectroscopy and numerical analysis on irradiation effect on residual stress were used to explain how the microstructural variables, especially of carbon interphases, affect the mechanical properties in the 30–40 dpa dose range.

Continuous fiber-reinforced ceramic matrix composi