Engineering PapersSearch

NASA NTRS · 20180005546

Fan Noise Research: Basic Theory and an Application

Abstract

A brief over view of Fan Noise Theory and an application to the DART for a student seminar.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sutliff, Daniel L.. 2018-03-22. Fan Noise Research: Basic Theory and an Application. https://ntrs.nasa.gov/citations/20180005546

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

A 20 Year Retrospective of The Advanced Noise Control Fan - Contributions to Turbofan Noise Research

The Advanced Noise Control Fan (neé Active Noise Control Fan - ANCF) was utilized in the design, test, and evaluation for technical risk mitigation of most of the innovative fan noise reduction technologies developed by NASA over the past 20 years. The ANCF is a low-speed, ducted fan, testbed for measuring and understanding fan-generated aeroacoustics, duct propagation, and radiation to the farfield. It is considered a low Technology Readiness Level testbed. The international aeroacoustics research community employed the ANCF to facilitate advancement of multiple noise reduction and measurement technologies, and for code validation. From 1994 to 2016, it was located in the NASA Glenn Research Center’s Aero-Acoustic Propulsion Laboratory. In 2016 the ANCF was transferred to the University of Notre Dame where it is expected to continue to positively impact ducted fan aeroacoustic research and provide STEM support. This paper summarizes the capabilities and contributions of the ANCF to the field by documenting its history. Limited data is presented, focusing on a description of the configurations, goals, and objectives of representative ANCF tests. This provides an overview of the progress of aeroacosustic research as implemented on the ANCF, as well as a background for its continued usage.

Fan Noise

Source Diagnostic Fan II (22-Inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

A 22-inch scale model of the Honeywell Quiet High Speed Fan II was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel at a tunnel Mach number of 0.10. This was an entry to investigate the effect of “stator clocking” on noise. The fan consisted of a moderately aft swept rotor, and an aft swept set of stator vanes. The fan stage consisted of 22 rotor blades, 50 stator vanes, and 10 downstream support struts. A set of stator vanes designed for lower noise was tested as well as a baseline stator vane set. The stator assembly could be rotated several degrees to adjust the clocking angle between the stator vane pack and the strut assembly. All configurations were with a hard wall duct (no acoustic treatment). The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present in the ducted fan. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For the two stator configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator and rotor-strut interaction acoustic levels for the interaction modes. Varying the angle between the stators and struts was shown to be a viable method to achieve a minimum in rotor-strut interaction mode power level. Multiple-pure-tones generated by the Quiet High Speed Fan II in the inlet were also measured.

Fan Noise