Engineering PapersSearch

NASA NTRS · 20170005533

Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program

Abstract

Accurate predictions of the thermodynamic state of the cryogenic propellants, pressurization rate, and performance of pressure control techniques in cryogenic tanks are required for development of cryogenic fluid long-duration storage technology and planning for future space exploration missions. This Technical Memorandum (TM) presents the analytical tool, Tank System Integrated Model (TankSIM), which can be used for modeling pressure control and predicting the behavior of cryogenic propellant for long-term storage for future space missions. Utilizing TankSIM, the following processes can be modeled: tank self-pressurization, boiloff, ullage venting, mixing, and condensation on the tank wall. This TM also includes comparisons of TankSIM program predictions with the test data andexamples of multiphase mission calculations.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bolshinskiy, L. G., Hedayat, A., Hastings, L. J., Sutherlin, S. G., Schnell, A. R., Moder, J. P.. 2017-04-01. Tank System Integrated Model: A Cryogenic Tank Performance Prediction Program. https://ntrs.nasa.gov/citations/20170005533