Engineering PapersSearch

NASA NTRS · 20150018088

Results from CrIS/ATMS Obtained Using an AIRS "Version-6 like" Retrieval Algorithm

Abstract

We tested and evaluated Version-6.22 AIRS and Version-6.22 CrIS products on a single day, December 4, 2013, and compared results to those derived using AIRS Version-6. AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6All AIRS and CrIS products agree reasonably well with each other. CrIS Version-6.22 T(p) and q(p) results are slightly poorer than AIRS over land, especially under very cloudy conditions. Both AIRS and CrIS Version-6.22 run now at JPL. Our short term plans are to analyze many common months at JPL in the near future using Version-6.22 or a further improved algorithm to assess the compatibility of AIRS and CrIS monthly mean products and their interannual differences. Updates to the calibration of both CrIS and ATMS are still being finalized. JPL plans, in collaboration with the Goddard DISC, to reprocess all AIRS data using a still to be finalized Version-7 retrieval algorithm, and to reprocess all recalibrated CrISATMS data using Version-7 as well.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Susskind, Joel, Kouvaris, Louis, Iredell, Lena. 2015-08-27. Results from CrIS/ATMS Obtained Using an AIRS "Version-6 like" Retrieval Algorithm. https://ntrs.nasa.gov/citations/20150018088

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related reports

Results from CrIS/ATMS Obtained Using an "AIRS Version-6 Like" Retrieval Algorithm

AIRS and CrIS Version-6.22 O3(p) and q(p) products are both superior to those of AIRS Version-6.Monthly mean August 2014 Version-6.22 AIRS and CrIS products agree reasonably well with OMPS, CERES, and witheach other. JPL plans to process AIRS and CrIS for many months and compare interannual differences. Updates to thecalibration of both CrIS and ATMS are still being finalized. We are also working with JPL to develop a joint AIRS/CrISlevel-1 to level-3 processing system using a still to be finalized Version-7 retrieval algorithm. The NASA Goddard DISCwill eventually use this system to reprocess all AIRS and recalibrated CrIS/ATMS. .

CrIS ATMS

Retrieved Products from Simulated Hyperspectral Observations of a Hurricane

Retrievals were run using the AIRS Science Team Version-6 AIRS Only retrieval algorithm, which generates a Neural-Net first guess (T(sub s))(sup 0), (T(p))(sup 0), and (q(p))(sup 0) as a function of observed AIRS radiances. AIRS Science Team Neural-Net coefficients performed very well beneath 300 mb using the simulated radiances. This means the simulated radiances are very realistic. First guess and retrieved values of T(p) above 300 mb were biased cold, but both represented the model spatial structure very well. QC'd T(p) and q(p) retrievals for all experiments had similar accuracies compared to their own truth fields, and were roughly consistent with results obtained using real data. Spatial coverage of retrievals, as well as the representativeness of the spatial structure of the storm, improved dramatically with decreasing size of the instrument's FOV. We sent QC'd values of T(p) and q(p) to Bob Atlas at AOML for use as input to OSSE Data Assimilation experiments.

CrIS ATMS