Abstract
Remote sensing technologies are being considered for efficient, low cost gas leak detection. Eleven specific techniques have been identified for further study and evaluation of several of these is underway. The Indirect Thermal Technique is one of the techniques that is being explored. For this technique, an infrared camera is used to detect the temperature change of a pipe or fitting at the site of a gas leak. This temperature change is caused by the change in temperature of the gas expanding from the leak site. During the 10-week NFFP program, the theory behind the technique was further developed, experiments were performed to determine the conditions for which the technique might be viable, and a proof-of-concept system was developed and tested in the laboratory.
Keep this discovery
Explore connections, maps & timelines
Clements, Sandra. 2002-12-01. Remote Leak Detection: Indirect Thermal Technique. https://ntrs.nasa.gov/citations/20030062817
Cite the original work for its findings. Save a collection to share your selection of sources.