Noncavitating Pump For Liquid Helium
Abstract
Immersion pump features high efficiency in cryogenic service. Simple and reliable centrifugal pump transfers liquid helium with mass-transfer efficiency of 99 percent. Liquid helium drawn into pump by helical inducer, which pressurizes helium slightly to prevent cavitation when liquid enters impeller. Impeller then pressurizes liquid. Purpose of pump to transfer liquid helium from supply to receiver vessel, or to provide liquid helium flow for testing and experimentation.
Keep this discovery
Explore connections, maps & timelines
Hasenbein, Robert, Izenson, Michael, Swift, Walter, Sixsmith, Herbert. 1996-03-01. Noncavitating Pump For Liquid Helium. https://ntrs.nasa.gov/citations/19960018826