NASA NTRS · 19920043088
Integrated numerical methods for hypersonic aircraft cooling systems analysis
Abstract
Numerical methods have been developed for the analysis of hypersonic aircraft cooling systems. A general purpose finite difference thermal analysis code is used to determine areas which must be cooled. Complex cooling networks of series and parallel flow can be analyzed using a finite difference computer program. Both internal fluid flow and heat transfer are analyzed, because increased heat flow causes a decrease in the flow of the coolant. The steady state solution is a successive point iterative method. The transient analysis uses implicit forward-backward differencing. Several examples of the use of the program in studies of hypersonic aircraft and rockets are provided.
Keep this discovery
Explore connections, maps & timelines
Petley, Dennis H., Jones, Stuart C., Dziedzic, William M.. 1992-01-01. Integrated numerical methods for hypersonic aircraft cooling systems analysis. https://ntrs.nasa.gov/citations/19920043088
Cite the original work for its findings. Save a collection to share your selection of sources.