Abstract
Since the response of deployable structural concepts being considered for the Large Deployable Reflector (LDR) backup structure will be dominated by the response of joints, the joint characteristics are significant. An overview is given of the research activities at LaRC on the static behavior of joints for deployable space truss structures. Since a pin-clevis-type joint will be utilized in deployable structures, an experimental research program to characterize the joint parameters which affect stiffness was conducted. An experimental research program was conducted on a second type of joint, referred to as a near-center latch joint. It was used in the center of members on the deployable truss structure for the Control of Flexible Structures (COFS) flight experiment. The test results of the near-center latch joint and the member with the joints indicated that the stiffness of the near-center joint is linear and stiffer than the stiffness of the total member, and that non-linearities in the stiffness characteristics of the total member were due to bending introduced at the ends of the member. The resulting data indicates that stiff linear folding joints can be designed and that bending load paths should be avoided whenever possible. In summary, for deployable structures, special attention to the joint and the structure design is required to minimize the undesirable structural non-linearities.