Sealing Nitrogen Tetroxide Leaks

Abstract

Use of Furmanite FSC-N-6B sealant in clam-shell sealing device makes it possible to stop leaks of nitrogen tetroxide through defective or improperly-seated plumbing fittings. Devised to stop leaks in vent line of small rocket motor on Space Shuttle. Also used on plumbing containing hydrazine and other hazardous fluids, and repair withstands severe temperature, vibration, and shock. Leaks stopped in place, without draining or replacement of leaking parts.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Garrard, George G., Houston, Donald W., Scott, Frank D.. 1990-11-01. Sealing Nitrogen Tetroxide Leaks. https://ntrs.nasa.gov/citations/19900000608