Engineering PapersโŒ• Search

NASA NTRS ยท 19880015675

Small scale bipolar nickel-hydrogen testing

Abstract

Bipolar nickel-hydrogen batteries, ranging in capacity from 6 to 40 A-hr, have been tested at the NASA Lewis Research Center over the past six years. Small scale tests of 1 A-hr nickel-hydrogen stacks have been initiated as a means of screening design and component variations for bipolar nickel-hydrogen cells and batteries. Four small-scale batteries have been built and tested. Characterization and limited cycle testing were performed to establish the validity of test results in the scaled down hardware. The results show characterization test results to be valid. LEO test results in the small scale hardware have limited value.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Manzo, Michelle A.. 1988-01-01. Small scale bipolar nickel-hydrogen testing. https://ntrs.nasa.gov/citations/19880015675