Engineering PapersโŒ• Search

NASA NTRS ยท 19830000177

Eddy-Current Damage Test for Carbon Composites

Abstract

Nondestructive test method detects cracks in materials of low conductivity. Test setup includes eddycurrent unit with frequency of 2 to 20 MHz/ and storage oscilloscope. High frequency required to assure depth of penetration less than substrate thickness, to prevent thickness from influencing reading. Eddy-current analysis confirmed by visual inspection as damaged area was sectioned and evaluated.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hamilton, A. B.. 1983-10-01. Eddy-Current Damage Test for Carbon Composites. https://ntrs.nasa.gov/citations/19830000177

Cite the original work for its findings. Save a collection to share your selection of sources.