Engineering Papers⌕ Search

NASA NTRS · 19800013892

Shuttle orbit IMU alignment. Single-precision computation error

Abstract

The source of computational error in the inertial measurement unit (IMU) onorbit alignment software was investigated. Simulation runs were made on the IBM 360/70 computer with the IMU orbit alignment software coded in hal/s. The results indicate that for small IMU misalignment angles (less than 600 arc seconds), single precision computations in combination with the arc cosine method of eigen rotation angle extraction introduces an additional misalignment error of up to 230 arc seconds per axis. Use of the arc sine method, however, produced negligible misalignment error. As a result of this study, the arc sine method was recommended for use in the IMU onorbit alignment software.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mcclain, C. R.. 1980-03-01. Shuttle orbit IMU alignment. Single-precision computation error. https://engineeringpapers.com/record/nasa%3A19800013892/shuttle-orbit-imu-alignment-single-precision-computation-error