Liquid-metal magnetohydrodynamic system evaluation

Abstract

The present study emphasizes a direct coal-fired design using a bubbly two-component flow of sodium and argon in the MHD generator and a Rankine steam-bottoming plant. Two basic cycles were studied, corresponding to argon temperatures of 922 and 1089 K at the duct inlet. The MHD duct system consisted of multiple ducts arranged in clusters and separated by iron magnet pole pieces. The ducts, each with an output of about 100 MW, were parallel to the flow, but were connected in series electrically to provide a higher MHD voltage. With channel efficiencies of 80%, a pump efficiency of 90%, and a 45% efficient steam-bottoming plant, the overall efficiency of the 1089 K liquid-metal MHD power plant was 43%.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Holman, R. R., Lippert, T. E.. 1976-01-01. Liquid-metal magnetohydrodynamic system evaluation. https://ntrs.nasa.gov/citations/19770029932